Alternative statistical parameter for high-throughput screening assay quality assessment

被引:98
作者
Sui, Yunxia
Wu, Zhijin [1 ]
机构
[1] Brown Univ, Dept Community Hlth, Providence, RI 02912 USA
[2] Brown Univ, Ctr Stat Sci, Providence, RI 02912 USA
关键词
high-throughput screening; statistics; Z factor; power; assay validation;
D O I
10.1177/1087057106296498
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
High-throughput screening is an essential process in drug discovery. The ability to identify true active compounds depends on the high quality of assays and proper analysis of data. The Z factor, presented by Zhang et at. in 1999, provides an easy and useful summary of assay quality and has been a widely accepted standard. However, as data analysis has undergone much improvement recently, the assessment of assay quality has not evolved in parallel. In this article, the authors study the implications of Z factor values under different conditions and link the Z factor with the power of discovering true active compounds. They discuss the different interpretations of Z factor depending on error distributions and advocate direct analysis of power as assay quality assessment. They also propose that in estimating assay quality parameters, adjustments in data analysis should be taken into account. Studying the power of identifying true "hits" gives a more direct interpretation of assay quality and may provide guidance in assay optimization on some occasions.
引用
收藏
页码:229 / 234
页数:6
相关论文
共 6 条
[1]
Improved statistical methods for hit selection in high-throughput screening [J].
Brideau, C ;
Gunter, B ;
Pikounis, B ;
Liaw, A .
JOURNAL OF BIOMOLECULAR SCREENING, 2003, 8 (06) :634-647
[2]
Statistical and graphical methods for quality control determination of high-throughput screening data [J].
Gunter, B ;
Brideau, C ;
Pikounis, B ;
Liaw, A .
JOURNAL OF BIOMOLECULAR SCREENING, 2003, 8 (06) :624-633
[3]
A comparison of assay performance measures in screening assays:: Signal window, Z′ factor, and assay variability ratio [J].
Iversen, PW ;
Eastwood, BJ ;
Sittampalam, GS ;
Cox, KL .
JOURNAL OF BIOMOLECULAR SCREENING, 2006, 11 (03) :247-252
[4]
A simple technique for reducing edge effect in cell-based assays [J].
Lundholt, BK ;
Scudder, KM ;
Pagliaro, L .
JOURNAL OF BIOMOLECULAR SCREENING, 2003, 8 (05) :566-570
[5]
Statistical practice in high-throughput screening data analysis [J].
Malo, N ;
Hanley, JA ;
Cerquozzi, S ;
Pelletier, J ;
Nadon, R .
NATURE BIOTECHNOLOGY, 2006, 24 (02) :167-175
[6]
A simple statistical parameter for use in evaluation and validation of high throughput screening assays [J].
Zhang, JH ;
Chung, TDY ;
Oldenburg, KR .
JOURNAL OF BIOMOLECULAR SCREENING, 1999, 4 (02) :67-73