A simple approach to compensate the suction caused by the electrospray ionization source in capillary electrophoresis-mass spectrometry systems

被引:8
作者
do Lago, Claudimir Lucio [1 ]
Rajh Vidal, Denis Tadeu [1 ]
Mendonca Francisco, Kelliton Jose [1 ]
dos Santos, Vagner Bezerra [1 ]
机构
[1] Univ Sao Paulo, Dept Quim Fundamental, Inst Quim, BR-05508000 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Backpressure; Efficiency; Electrospray; Mass spectrometry; ESI-MS; FLOW; INTERFACE; INSIGHT; PLASMA;
D O I
10.1002/elps.201300651
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
ESI sources continuously consume the liquid at the tip of the capillary, which causes the dragging of the BGE. The laminar nature of this flow causes the broadening of the peaks and loss of separation efficiency. The usual solution for this problem is to compensate this phenomenon by reducing the pressure at the inlet vial by either leveling of this vial or pumping off the air that is over it. However, one must know the pressure to be applied in order to prevent under-or over-compensation. The procedure herein introduced allows the easy calculation of this pressure by obtaining two electropherograms at two different values of separation voltage. The migration times of the peaks allow the calculation of the apparent mobilities even in the presence of the laminar flow. Therefore, one can calculate the contributions from both electrophoresis and hydrodynamic flow, and finally the pressure associated with the undesirable flow. This pressure is then applied as a negative pressure at the inlet vial in the following experiments. Increase of up to 192% in the number of plates was obtained in a simple experiment. In addition, the bubble forming caused by the ESI suction during injection was prevented by turning off the nebulizer gas during the changes of inlet vials.
引用
收藏
页码:2412 / 2416
页数:5
相关论文
共 15 条
[1]
Capillary electrophoresis-electrospray ionization-mass spectrometry interfaces: Fundamental concepts and technical developments [J].
Bonvin, Gregoire ;
Schappler, Julie ;
Rudaz, Serge .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1267 :17-31
[2]
Fast capillary electrophoresis-time-of-flight mass spectrometry using capillaries with inner diameters ranging from 75 to 5 μm [J].
Grundmann, Marco ;
Matysik, Frank-Michael .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (01) :269-278
[3]
QUANTITATIVE CAPILLARY ELECTROPHORESIS ION SPRAY MASS-SPECTROMETRY ON A BENCHTOP ION-TRAP FOR THE DETERMINATION OF ISOQUINOLINE ALKALOIDS [J].
HENION, JD ;
NLORDEHAI, AV ;
CAI, JY .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2103-2109
[4]
Effects of nebulizing and drying gas flow on capillary electrophoresis/mass spectrometry [J].
Huikko, K ;
Kotiaho, T ;
Kostiainen, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (16) :1562-1568
[5]
Quantitative analysis of six pesticides in fruits by capillary electrophoresis-electrospray-mass spectrometry [J].
Juan-García, A ;
Font, G ;
Picó, Y .
ELECTROPHORESIS, 2005, 26 (7-8) :1550-1561
[6]
Kasicka V, 2000, J CHROMATOGR B, V741, P43
[7]
Effect of laminar flow in capillary electrophoresis: Model and experimental results on controlling analysis time and resolution with inductively coupled plasma mass spectrometry detection [J].
Kinzer, JA ;
Olesik, JW ;
Olesik, SV .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3250-3257
[8]
Easy peak tracking in CE-UV and CE-UV-ESI-MS by incorporating temperature-correlated mobility scaling [J].
Li, Bin ;
Petersen, Nickolaj J. ;
Andersen, Line H. ;
Hansen, Steen H. .
ELECTROPHORESIS, 2013, 34 (12) :1787-1795
[9]
Twenty years of interface development for capillary electrophoresis-electrospray ionization-mass spectrometry [J].
Maxwell, E. Jane ;
Chen, David D. Y. .
ANALYTICA CHIMICA ACTA, 2008, 627 (01) :25-33
[10]
A new insight into suction and dilution effects in capillary electrophoresis coupled to mass spectrometry via an electrospray ionization interface.: Part I-Suction effect [J].
Mokaddem, Meriem ;
Gareil, Pierre ;
Belgaied, Jamel-Eddine ;
Varenne, Anne .
ELECTROPHORESIS, 2008, 29 (10) :1957-1964