Fast capillary electrophoresis-time-of-flight mass spectrometry using capillaries with inner diameters ranging from 75 to 5 μm

被引:28
作者
Grundmann, Marco [1 ]
Matysik, Frank-Michael [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93053 Regensburg, Germany
关键词
Capillary electrophoresis; Time-of-flight mass spectrometry; Electrospray ionization; Fused silica capillaries; High electric field strengths; Catecholamines; FUSED-SILICA CAPILLARIES; FLOW GATING INTERFACE; ELECTROSPRAY-IONIZATION; ZONE-ELECTROPHORESIS; MICROCOLUMN-LC; CE/ESI-MS; INJECTION; CATECHOLAMINES; VOLTAMMETRY; DOPAMINE;
D O I
10.1007/s00216-011-4719-7
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Fast electrophoretic separations in fused silica capillaries (CE) coupled to time-of-flight mass spectrometry (TOF-MS) are presented. CE separations of the model analytes (epinephrine, norepinephrine, dopamine, histidine, and isoproterenol) under conditions of high electric field strengths of up to 1.25 kV cm(-1) are completed in 20 s. Coupling of CE with TOF-MS is accomplished using a coaxial sheath liquid electrospray ionization interface. The influence of parameters inherent to the interface and their effects, including suction pressure and dilution, are discussed. In addition to standard capillaries of 75 and 50 mu m inner diameter (ID), separations in capillaries with IDs of 25, 15, and 5 mu m have been successfully applied to this setup. The analytical performance is compared over this range of capillary dimensions, and both advantages and disadvantages are discussed.
引用
收藏
页码:269 / 278
页数:10
相关论文
共 45 条
[1]
Improvement of the long-term stability of polyimide-coated fused-silica capillaries used in capillary electrophoresis and capillary electrochromatography [J].
Baeuml, F ;
Welsch, T .
JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (01) :35-44
[2]
Comparison of detection performance of UV and electrochemical detection in NACE for a range of different capillary inner diameters [J].
Blasco, Sonia ;
Kortz, Linda ;
Matysik, Frank-Michael .
ELECTROPHORESIS, 2009, 30 (19) :3355-3360
[3]
Flow injection of the lock mass standard for accurate mass measurement in electrospray ionization time-of-flight mass spectrometry coupled with liquid chromatography [J].
Charles, L .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (13) :1383-1388
[4]
ESTIMATION OF FREE DOPAMINE IN THE CYTOPLASM OF THE GIANT DOPAMINE CELL OF PLANORBIS-CORNEUS BY VOLTAMMETRY AND CAPILLARY ELECTROPHORESIS [J].
CHIEN, JB ;
WALLINGFORD, RA ;
EWING, AG .
JOURNAL OF NEUROCHEMISTRY, 1990, 54 (02) :633-638
[5]
Dependence of the electroosmotic flow in bare fused-silica capillaries from pH, ionic strength and composition of electrolyte solutions tailored for protein capillary zone electrophoresis [J].
Corradini, D ;
Sprecacenere, L .
CHROMATOGRAPHIA, 2003, 58 (9-10) :587-596
[6]
Dawson R. M. C., 1959, DATA BIOCH RES
[7]
Drayton C.J., 1990, Comprehensive Medicine Chemistry. Vol, V6, DOI DOI 10.1016/j.talanta.2004.02.038
[8]
A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes [J].
Enke, CG .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4885-4893
[9]
FAST, HIGH-RESOLUTION (CAPILLARY) ELECTROPHORESIS IN BUFFERS DESIGNED FOR HIGH-FIELD STRENGTHS [J].
HJERTEN, S ;
VALTCHEVA, L ;
ELENBRING, K ;
LIAO, JL .
ELECTROPHORESIS, 1995, 16 (04) :584-594
[10]
DETERMINATION OF INTRACELLULAR SPECIES AT THE LEVEL OF A SINGLE ERYTHROCYTE VIA CAPILLARY ELECTROPHORESIS WITH DIRECT AND INDIRECT FLUORESCENCE DETECTION [J].
HOGAN, BL ;
YEUNG, ES .
ANALYTICAL CHEMISTRY, 1992, 64 (22) :2841-2845