Diffusion-weighted imaging (DWI) in MR mammography (MRM): clinical comparison of echo planar imaging (EPI) and half-Fourier single-shot turbo spin echo (HASTE) diffusion techniques

被引:99
作者
Baltzer, P. A. T. [1 ]
Renz, D. M. [1 ]
Herrmann, K. -H. [2 ]
Dietzel, M. [1 ]
Krumbein, I. [1 ,2 ]
Gajda, M. [3 ]
Camara, O. [4 ]
Reichenbach, J. R. [2 ]
Kaiser, W. A. [1 ]
机构
[1] Univ Jena, Inst Diagnost & Intervent Radiol, D-07740 Jena, Germany
[2] Univ Clin Jena, Med Phys Grp, Inst Diagnost & Intervent Radiol, D-07743 Jena, Germany
[3] Univ Jena, Inst Pathol, D-07740 Jena, Germany
[4] Univ Jena, Clin Gynecol, D-07740 Jena, Germany
关键词
Breast; Neoplasm; MRI; DWI; Sensitivity and specificity; BREAST-CANCER; DIFFERENTIAL-DIAGNOSIS; LESIONS; ACCURACY; TUMORS; SEQUENCES; BENIGN; DTPA;
D O I
10.1007/s00330-009-1326-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Diffusion-weighted imaging (DWI) techniques have shown potential to differentiate between benign and malignant neoplasms. However, the diagnostic significance of using DWI under routine conditions remains unclear. This study investigated the use of echo planar imaging (EPI) and half-Fourier acquired single-shot turbo spin echo (HASTE)-DWI with respect to the three parameters: lesion visibility, apparent diffusion coefficient (ADC) measurements, and size estimation. Following MRM (1.5 T), EPI- and HASTE-DWI were applied in 65 patients. Lesion visibility on DWI was compared with lesion visibility on subtracted contrast-enhanced T1w images (CE-T1w). Statistical tests were applied to diameter, visibility, and ADC value measurements. Seventy-four lesions were identified. ADC value measurements did not differ significantly between the two DWI sequences. The sensitivity and specificity of routine diagnostics (97.4% and 85.7%) were superior to EPI-DWI (87.2% and 82.9%) and HASTE-DWI (76.9% and 88.6%). Selecting only nonmass lesions, DWI did not prove to be of diagnostic value. Lesion demarcation by DWI was significantly lower compared with that by CE-T1w, with EPI-DWI showing the better performance (p < 0.001). No significant differences were found for size measurements between CE-T1w and DWI. Although clearly inferior compared with CE-T1w imaging, both DWI techniques are applicable for lesion assessment and size measurements.
引用
收藏
页码:1612 / 1620
页数:9
相关论文
共 29 条
[1]
Classification of hypervascularized lesions in CE MR imaging of the breast [J].
Baum, F ;
Fischer, U ;
Vosshenrich, R ;
Grabbe, E .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1087-1092
[2]
Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer [J].
Berg, WA ;
Gutierrez, L ;
NessAiver, MS ;
Carter, WB ;
Bhargavan, M ;
Lewis, RS ;
Ioffe, OB .
RADIOLOGY, 2004, 233 (03) :830-849
[3]
Overall breast density in MR mammography -: Diagnostic and therapeutic implications in breast cancer [J].
Echevarria, JJ ;
Martín, M ;
Saiz, A ;
Imaz, I ;
Férnandez-Ruanova, B ;
Martín, D ;
López-Ruiz, JA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (01) :140-147
[4]
Echoplanar diffusion-weighted MRI with intravenous gadolinium-DTPA [J].
Fitzek, C ;
Mentzel, HJ ;
Fitzek, S ;
Sauner, D ;
Kaiser, WA ;
Reichenbach, JR .
NEURORADIOLOGY, 2003, 45 (09) :592-597
[5]
Differentiation of clinically benign and malignant breast lesions using diffusion-weighted imaging [J].
Guo, Y ;
Cai, YQ ;
Cai, ZL ;
Gao, YG ;
An, NY ;
Ma, L ;
Mahankali, S ;
Gao, JH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) :172-178
[6]
Hatakenaka Masamitsu, 2008, Magn Reson Med Sci, V7, P23, DOI 10.2463/mrms.7.23
[7]
Accuracy and surgical impact of magnetic resonance imaging in breast cancer staging: Systematic review and meta-analysis in detection of multifocal and multicentric cancer [J].
Houssami, Nehmat ;
Ciatto, Stefano ;
Macaskill, Petra ;
Lord, Sarah J. ;
Warren, Ruth M. ;
Dixon, J. Michael ;
Irwig, Les .
JOURNAL OF CLINICAL ONCOLOGY, 2008, 26 (19) :3248-3258
[8]
Ikeda DM, 2003, MRI BREAST IMAGING R
[9]
KAISER W, 1985, ARCH INT PHYSIOL BIO, V93, P67, DOI 10.3109/13813458509080627
[10]
MR IMAGING OF THE BREAST - FAST IMAGING SEQUENCES WITH AND WITHOUT GD-DTPA - PRELIMINARY-OBSERVATIONS [J].
KAISER, WA ;
ZEITLER, E .
RADIOLOGY, 1989, 170 (03) :681-686