Capillary array high-performance liquid chromatography of nucleic acids and proteins

被引:26
作者
Premstaller, A
Oefner, PJ
Oberacher, H
Huber, CG
机构
[1] Stanford Univ, Genome Technol Ctr, Palo Alto, CA 94304 USA
[2] Univ Saarland, D-66123 Saarbrucken, Germany
关键词
D O I
10.1021/ac020272f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An array of monolithic poly(styrene/divinylbenzene) capillaries with individual column thermostats was constructed to demonstrate its utility for the separation of nucleic acids, proteins, and tryptic digests in combination with UV absorbance detection. Because of polymerization-related variation in surface area of monolithic columns, the concentration of acetonitrile required for elution of DNA fragments in denaturing HPLC may vary sufficiently to affect the degree of denaturation. Modulation of column temperature offers a convenient way to harmonize elution profiles among columns. Individual regulation of column temperature also provides the means to determine rapidly in a single parallel ran the optimum temperature for resolution of biomolecules. Given the high reproducibility of separations among columns and the ease with which poly(styrene/divinylbenzene)-based stationary phases can be modified to accommodate different modes of chromatography, such arrays will find broad applicability in proteogenomics.
引用
收藏
页码:4688 / 4693
页数:6
相关论文
共 28 条
[1]   FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY [J].
AFEYAN, NB ;
GORDON, NF ;
MAZSAROFF, I ;
VARADY, L ;
FULTON, SP ;
YANG, YB ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :1-29
[2]  
Bayliss MK, 2000, RAPID COMMUN MASS SP, V14, P2039, DOI 10.1002/1097-0231(20001115)14:21<2039::AID-RCM130>3.0.CO
[3]  
2-2
[4]  
de Biasi V, 1999, RAPID COMMUN MASS SP, V13, P1165, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1165::AID-RCM638>3.0.CO
[5]  
2-4
[6]   High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma [J].
Deng, Y ;
Wu, JT ;
Lloyd, TL ;
Chi, CL ;
Olah, TV ;
Unger, SE .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (11) :1116-1123
[7]   Fast characterization of intact proteins using a high-throughput eight-channel parallel liquid chromatography mass spectrometry system [J].
Feng, BB ;
Patel, AH ;
Keller, PM ;
Slemmon, JR .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (10) :821-826
[8]  
GOD R, 2001, AM LAB NEWS, P20
[9]   An absorption detection approach for multiplexed capillary electrophoresis using a linear photodiode array [J].
Gong, XY ;
Yeung, ES .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4989-4996
[10]   Single nucleotide polymorphism markers for genetic mapping in Drosophila melanogaster [J].
Hoskins, RA ;
Phan, AC ;
Naeemuddin, M ;
Mapa, FA ;
Ruddy, DA ;
Ryan, JJ ;
Young, LM ;
Wells, T ;
Kopczynski, C ;
Ellis, MC .
GENOME RESEARCH, 2001, 11 (06) :1100-1113