Capillary array high-performance liquid chromatography of nucleic acids and proteins

被引:26
作者
Premstaller, A
Oefner, PJ
Oberacher, H
Huber, CG
机构
[1] Stanford Univ, Genome Technol Ctr, Palo Alto, CA 94304 USA
[2] Univ Saarland, D-66123 Saarbrucken, Germany
关键词
D O I
10.1021/ac020272f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An array of monolithic poly(styrene/divinylbenzene) capillaries with individual column thermostats was constructed to demonstrate its utility for the separation of nucleic acids, proteins, and tryptic digests in combination with UV absorbance detection. Because of polymerization-related variation in surface area of monolithic columns, the concentration of acetonitrile required for elution of DNA fragments in denaturing HPLC may vary sufficiently to affect the degree of denaturation. Modulation of column temperature offers a convenient way to harmonize elution profiles among columns. Individual regulation of column temperature also provides the means to determine rapidly in a single parallel ran the optimum temperature for resolution of biomolecules. Given the high reproducibility of separations among columns and the ease with which poly(styrene/divinylbenzene)-based stationary phases can be modified to accommodate different modes of chromatography, such arrays will find broad applicability in proteogenomics.
引用
收藏
页码:4688 / 4693
页数:6
相关论文
共 28 条
[11]   RAPID ANALYSIS OF BIOPOLYMERS ON MODIFIED NONPOROUS POLYSTYRENE - DIVINYLBENZENE PARTICLES [J].
HUBER, CG ;
OEFNER, PJ ;
BONN, GK .
CHROMATOGRAPHIA, 1993, 37 (11-12) :653-656
[12]   RAPID AND ACCURATE SIZING OF DNA FRAGMENTS BY ION-PAIR CHROMATOGRAPHY ON ALKYLATED NONPOROUS POLY(STYRENE-DIVINYLBENZENE) PARTICLES [J].
HUBER, CG ;
OEFNER, PJ ;
BONN, GK .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :578-585
[13]   EVALUATION OF ADVANCED SILICA PACKINGS FOR THE SEPARATION OF BIO-POLYMERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .6. DESIGN, CHROMATOGRAPHIC PERFORMANCE AND APPLICATION OF NON-POROUS SILICA-BASED ANION-EXCHANGERS [J].
JILGE, G ;
UNGER, KK ;
ESSER, U ;
SCHAFER, HJ ;
RATHGEBER, G ;
MULLER, W .
JOURNAL OF CHROMATOGRAPHY, 1989, 476 :37-48
[14]  
Jones AC, 1999, CLIN CHEM, V45, P1133
[15]   Multidimensional separations for protein/peptide analysis in the post-genomic era [J].
Liu, HB ;
Lin, DY ;
Yates, JR .
BIOTECHNIQUES, 2002, 32 (04) :898-+
[16]  
Minarik M, 2002, ELECTROPHORESIS, V23, P35, DOI 10.1002/1522-2683(200201)23:1<35::AID-ELPS35>3.0.CO
[17]  
2-H
[18]   Effects of temperature on retention of chiral compounds on a ristocetin A chiral stationary phase [J].
Péter, A ;
Vékes, E ;
Armstrong, DW .
JOURNAL OF CHROMATOGRAPHY A, 2002, 958 (1-2) :89-107
[19]   High-performance liquid chromatography-electrospray ionization mass spectrometry of single- and double-stranded nucleic acids using monolithic capillary columns [J].
Premstaller, A ;
Oberacher, H ;
Huber, CG .
ANALYTICAL CHEMISTRY, 2000, 72 (18) :4386-4393
[20]   High-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic capillary columns for proteomic studies [J].
Premstaller, A ;
Oberacher, H ;
Walcher, W ;
Timperio, AM ;
Zolla, L ;
Chervet, JP ;
Cavusoglu, N ;
van Dorsselaer, A ;
Huber, CG .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2390-+