Validation of diffusion tensor MRI-based muscle fiber tracking

被引:187
作者
Damon, BM
Ding, ZH
Anderson, AW
Freyer, AS
Gore, JC
机构
[1] Yale Univ, Sch Med, Dept Diagnost Radiol, New Haven, CT 06520 USA
[2] Yale Univ, Yale Coll, New Haven, CT 06520 USA
关键词
in vivo; gastrocnemius; pennation; rat; DT-MRI;
D O I
10.1002/mrm.10198
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diffusion-tensor (DT) MRI fiber tracking may potentially be used for in vivo structural analysis. The purpose of this study was to assess quantitatively the ability of a DT-MRI fiber-tracking algorithm to measure the fiber orientation (pennation) in skeletal muscle in vivo. In five adult Sprague-Dawley rats, the pennation angle (theta) was measured in the rat lateral gastrocnemius with DT-MRI (theta(DT-mRI)) and by direct anatomical inspection (DAI) (theta(DAI)). The mean theta(DT-MRI) was not significantly different from the mean theta(DAI). In addition, the two methods were highly correlated (r = 0.89) and the regression of theta(DT-MRI) on theta(DAI) resulted in a slope not significantly different from 1 and an intercept not significantly different from zero. These data indicate that DT-MRI-based fiber tracking as implemented here is a valid tool for in vivo structural analysis of small-animal skeletal muscle, (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 36 条
[1]   MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[2]  
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
[3]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[4]   PULSED NMR STUDIES OF WATER IN STRIATED-MUSCLE .1. TRANSVERSE NUCLEAR SPIN RELAXATION-TIMES AND FREEZING EFFECTS [J].
BELTON, PS ;
JACKSON, RR ;
PACKER, KJ .
BIOCHIMICA ET BIOPHYSICA ACTA, 1972, 286 (01) :16-&
[5]   EFFECT OF TEMPERATURE, TIME AND FASCICLE SIZE ON THE CAFFEINE CONTRACTURE TEST [J].
BRITT, BA ;
ENDRENYI, L ;
SCOTT, E ;
FRODIS, W .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1980, 27 (01) :1-11
[6]   NUCLEAR MAGNETIC-RESONANCE MEASUREMENT OF SKELETAL-MUSCLE - ANISOTROPY OF DIFFUSION-COEFFICIENT OF INTRACELLULAR WATER [J].
CLEVELAND, GG ;
CHANG, DC ;
HAZLEWOOD, CF ;
RORSCHACH, HE .
BIOPHYSICAL JOURNAL, 1976, 16 (09) :1043-1053
[7]   Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results [J].
Conturo, TE ;
McKinstry, RC ;
Akbudak, E ;
Robinson, BH .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :399-412
[8]   Case study: Reconstruction, visualization and quantification of neuronal fiber pathways [J].
Ding, ZH ;
Gore, JC ;
Anderson, AW .
VISUALIZATION 2001, PROCEEDINGS, 2001, :453-456
[9]  
ENGLEHARDT RT, 2001, P WORKSH NON INV MUS, P34
[10]   Determination of fascicle length and pennation in a contracting human muscle in vivo [J].
Fukunaga, T ;
Ichinose, Y ;
Ito, M ;
Kawakami, Y ;
Fukashiro, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (01) :354-358