Gamma-ray spectroscopy with LaBr3:Ce scintillator readout by a silicon drift detector

被引:42
作者
Fiorini, C. [1 ]
Gola, A.
Zanchi, M.
Longoni, A.
Lechner, P.
Soltau, H.
Strueder, L.
机构
[1] Politecn Milan, Dipartimento Elettr & Informaz Politecn Milano, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, Sez Milano, I-20133 Milan, Italy
[3] PNSensor GmbH, Munich, Germany
[4] MPI Semicond Lab, Munich, Germany
关键词
gamma-ray spectroscopy; LaBr3; silicon drift detectors;
D O I
10.1109/TNS.2006.878274
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the authors propose a gamma-ray spectrometer based on a LaBr3:Ce scintillator coupled to a silicon drift detector (SDD). The SDD is a photodetector characterized by a very low noise thanks to the low value of output capacitance independent from the active area. With respect to a PMT, the SDD offers a higher quantum efficiency which reduces the spread associated to the statistic of photoelectrons generation. Also with respect to an APD, the SDD offers a lower photoelectrons statistic contribution, which, in the APD, is worsened by the excess noise factor with respect to pure Poisson statistics. Moreover, the SDD has a stable behavior, less sensitive to temperature and bias drift. In the past years, good energy resolutions were measured using a SDD coupled to a CsI:Tl crystal. However, the long shaping time, to be used with this scintillator to prevent ballistic deficit, was too far to exploit the best noise performances achievable with a SDD obtained at shaping times in the order of 1 mu s. On the contrary, this optimum shaping time is fully compatible with the short decay time of the LaBr3:Ce crystal (about 25 ns). The results of the experimental characterization of the LaBr3:Ce-SDD gamma-ray spectrometer are presented in this work and are compared with the performances achieved with the same crystal coupled to a PMT and to a CsI(Tl) crystal coupled to the same SDD. The SDD has an active area of 30 mm(2). Antireflective coatings have been implemented. Good energy resolutions were measured at room temperature, thanks to the low leakage current of the detector: 2.7% at the Cs-137 661.7 KeV line and 6.1% at the Co-57 122 KeV line. A resolution of 5.7% at 122 KeV line was measured at 0 degrees C.
引用
收藏
页码:2392 / 2397
页数:6
相关论文
共 9 条
[1]   Gamma ray spectroscopy with a ⊘19 x19 mm3 LaBr3 : 0.5% Ce3+ scintillator [J].
Dorenbos, P ;
de Haas, JTM ;
van Eijk, CWE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) :1289-1296
[2]   Light output and energy resolution of Ce3+-doped scintillators [J].
Dorenbos, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 486 (1-2) :208-213
[3]   Small prototype of Anger camera with submillimeter position resolution [J].
Fiorini, C ;
Perotti, F .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (04)
[4]   Gamma ray spectroscopy with CsI(Tl) scintillator coupled to silicon drift chamber [J].
Fiorini, C ;
Longoni, A ;
Perotti, F ;
Labanti, C ;
Lechner, P ;
Struder, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) :2553-2560
[5]  
MCCONNEL ML, 2004, SPIE, V5488
[6]   Potential for RbGd2Br7:Ce, LaBr3:Ce, LaBr3:Ce, and LuI3:Ce in nuclear medical imaging [J].
Moses, WW ;
Shah, KS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2) :317-320
[7]  
Shah KS, 2004, IEEE T NUCL SCI, V51, P2395, DOI [10.1109/TNS.2004.832616, 10.1109/tns.2004.832616]
[8]   Scintillation properties of LaBr3:Ce3+ crystals:: fast, efficient and high-energy-resolution scintillators [J].
van Loef, EVD ;
Dorenbos, P ;
van Eijk, CWE ;
Krämer, KW ;
Güdel, HU .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 486 (1-2) :254-258
[9]   High-energy-resolution scintillator:: Ce3+ activated LaBr3 [J].
van Loef, EVD ;
Dorenbos, P ;
van Eijk, CWE ;
Krämer, K ;
Güdel, HU .
APPLIED PHYSICS LETTERS, 2001, 79 (10) :1573-1575