A molecularly imprinted polymer solid phase extraction (MISPE) method combined with flow-injection chemiluminescence (FI-CL) for the determination of residual tetracycline (TC) in fish samples is presented. The molecularly imprinted polymer (MIP) of TC was synthesized and particles of this MIP were packed into a polytetrafluoroethylene (PTFE) tube, which was connected into the sampling loop of an eight-way injection valve and served as the MISPE column for on-line selective adsorption of TC. The eluent (CH3CN : HNO3 (0.01 mol L-1) = 4 : 1, v : v) was used for extracting the adsorbed TC, which could be detected by its good enhancing effect on the CL reaction between Ce(IV) and rhodamine B. The CL intensity is linear to TC concentration in the range from 4 x 10(-9) to 4 x 10(-7) g mL(-1). The detection limit is 1 x 10(-9) g mL(-1) (3 sigma) and the relative standard deviation is 2.4% (n = 9). The conditions of preconcentration, extraction and CL reaction were carefully studied. The selectivity experiment shows that the selectivity and sensitivity of the CL method could be improved greatly when MIP was used as a recognition material in SPE. However, the MISPE column interacted indiscriminately with oxytetracycline (OTC) with a 49 +/- 2% binding. An intermediate differential pulsed elution (DPE) step using 3% acetic acid as eluent was employed to remove OTC and other interfering substances. The proposed MISPE-CL method has been applied successfully to the determination of TC in fish samples. At the same time, the binding characteristics of the polymer to tetracycline were evaluated by batch and dynamic methods.
引用
收藏
页码:829 / 834
页数:6
相关论文
共 38 条
[11]   CONTINUOUS-FLOW CHEMILUMINOMETRIC DETERMINATION OF TETRACYCLINES IN PHARMACEUTICAL PREPARATIONS AND HONEY BY OXIDATION WITH N-BROMOSUCCINIMIDE [J].
HALVATZIS, SA ;
TIMOTHEOUPOTAMIA, MM ;
CALOKERINOS, AC .
ANALYST, 1993, 118 (06) :633-637
[12]   Chemiluminescence determination of tetracyclines using a tris(2,2′-bipyridine)ruthenium(II) and potassium permanganate system [J].
Han, HY ;
He, ZK ;
Zeng, Y .
ANALYTICAL SCIENCES, 1999, 15 (05) :467-470
[13]   Synthetic peptide receptors: Molecularly imprinted polymers for the recognition of peptides using peptide-metal interactions [J].
Hart, BR ;
Shea, KJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (09) :2072-2073
[14]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATIONS OF TETRACYCLINE DERIVATIVES USING VOLATILE MOBILE PHASES [J].
HASAN, T ;
COOPERMAN, BS .
JOURNAL OF CHROMATOGRAPHY, 1985, 321 (02) :462-466
[15]   LANTHANIDE-SENSITIZED LUMINESCENCE FOR THE DETECTION OF TETRACYCLINES [J].
HIRSCHY, LM ;
DOSE, EV ;
WINEFORDNER, JD .
ANALYTICA CHIMICA ACTA, 1983, 147 (MAR) :311-316
[16]   Molecularly imprinted solid phase extraction using stable isotope labeled compounds as template and liquid chromatography-mass spectrometry for trace analysis of bisphenol A in water sample [J].
Kawaguchi, M ;
Hayatsu, Y ;
Nakata, H ;
Ishii, Y ;
Ito, R ;
Saito, K ;
Nakazawa, H .
ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) :83-89
[17]   Molecular imprinting - New possibilities for sensor technology [J].
Kriz, D ;
Ramstrom, O ;
Mosbach, K .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :A345-A349
[18]   Molecularly imprinted solid phase extraction for rapid screening of metformin [J].
Lai, EPC ;
Feng, SY .
MICROCHEMICAL JOURNAL, 2003, 75 (03) :159-168
[19]   Chemiluminescence determination of tetracycline based on radical production in a basic acetonitrile-hydrogen peroxide reaction [J].
Lau, C ;
Lu, JZ ;
Kai, M .
ANALYTICA CHIMICA ACTA, 2004, 503 (02) :235-239
[20]   Productive and nonproductive substrate binding in enzyme mimics [J].
Lele, BS ;
Kulkarni, MG ;
Mashelkar, RA .
POLYMER, 1999, 40 (14) :4063-4070