Performance analysis of different high-temperature heat pump systems for low-grade waste heat recovery

被引:99
作者
Cao, Xing-Qi [1 ]
Yang, Wei-Wei [1 ]
Zhou, Fu [1 ]
He, Ya-Ling [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
High temperature heat pump; Thermodynamic analysis; Economic analysis; THERMOECONOMIC OPTIMIZATION; CYCLE;
D O I
10.1016/j.applthermaleng.2014.06.049
中图分类号
O414.1 [热力学];
学科分类号
摘要
Different heat pump systems were used to recover the heat from waste water with mean temperature of 45 degrees C and produce hot water with the temperature up to 95 degrees C. Those systems include single-stage vapor compression heat pump (system 1), two-stage heat pump with external heat exchanger (system 2), two-stage heat pump with refrigerant injection (system 3), two-stage heat pump with refrigerant injection and internal heat exchanger (system 4), two-stage heat pump with flash tank (system 5) and two-stage heat pump with flash tank and intercooler (system 6). Thermodynamic and economic analyses were conducted to compare the performance of each system. Results showed that the COP and exergy efficiency for both system 5 and system 6 are quite close, and much higher than those of other systems. Besides, the payback period of both systems and system 6 are also shorter as compared to other systems. Considering both the thermodynamic performance and economic quality of the system, system 5 is finally preferred since less initial investment is required for system 5 as compared to system 6. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:291 / 300
页数:10
相关论文
共 23 条
[1]   Studies on a two-stage transcritical carbon dioxide heat pump cycle with flash intercooling [J].
Agrawal, Neeraj ;
Bhattacharyya, Souvik .
APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) :299-305
[2]   Desalination using low grade heat in the process industry: Challenges and perspectives [J].
Ammar, Yasmine ;
Li, Hanning ;
Walsh, Conor ;
Thornley, Patricia ;
Sharifi, Vida ;
Roskilly, Anthony P. .
APPLIED THERMAL ENGINEERING, 2012, 48 :446-457
[3]  
[Anonymous], 2003, NIST STANDARD REFERE
[4]   Two-stage air-source heat pump for residential heating and cooling applications in northern US climates [J].
Bertsch, Stefan S. ;
Groll, Eckhard A. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07) :1282-1292
[5]   Energy efficiency analysis of air cycle heat pump dryers [J].
Braun, JE ;
Bansal, PK ;
Groll, EA .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (07) :954-965
[6]   Advances in heat pump systems: A review [J].
Chua, K. J. ;
Chou, S. K. ;
Yang, W. M. .
APPLIED ENERGY, 2010, 87 (12) :3611-3624
[7]   A modular approach to study the performance of a two-stage heat pump system for drying [J].
Chua, KJ ;
Chou, SK .
APPLIED THERMAL ENGINEERING, 2005, 25 (8-9) :1363-1379
[8]   A study on modeling and performance assessment of a heat pump system for utilizing low temperature geothermal resources in buildings [J].
Hepbasli, Arif ;
Balta, M. Tolga .
BUILDING AND ENVIRONMENT, 2007, 42 (10) :3747-3756
[9]   Integration of a heat pump into the heat supply system of a cheese production plant [J].
Kapustenko, Petro O. ;
Ulyev, Leonid M. ;
Boldyryev, Stanislav A. ;
Garev, Andrey O. .
ENERGY, 2008, 33 (06) :882-889
[10]   Study on the Application of High Temperature Heat Pump to Recover Waste Heat of Marine Diesel Engine [J].
Liu, Shi-jie ;
Chen, Wu ;
Cai, Zhen-xiong ;
Zheng, Chao-yu .
ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 1, PROCEEDINGS, 2009, :361-364