Electrochemical determination of levetiracetam by screen-printed based biosensors

被引:35
作者
Asuncion Alonso-Lomillo, M. [1 ]
Dominguez-Renedo, Olga [1 ]
Matos, Patricia [1 ]
Julia Arcos-Martinez, M. [1 ]
机构
[1] Univ Burgos, Fac Sci, Dept Analyt Chem, Burgos 09001, Spain
关键词
Screen-printed electrodes; Biosensors; Levetiracetam; Pharmaceutical drugs; Pyrrole; LIQUID-CHROMATOGRAPHIC DETERMINATION; HUMAN PLASMA; IMMOBILIZATION; SERUM; FILMS;
D O I
10.1016/j.bioelechem.2008.11.003
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This work shows an easy and fast electrochemical method for Levetiracetam (LEV) determination. which is a novel antiepileptic. Most of the methods used up to now for its determination required a pre-treatment of the sample. It is shown here that the developed Peroxidase based biosensors avoid this kind of drawbacks. Screen-printed carbon electrodes have been used as transducers for the Peroxidase immobilization by pyrrole electropolymerization. Experimental variables that can affect LEV chronoamperometric response, such as hydrogen peroxide concentration. pH and applied potential, have been optimized in order to perform a selective LEV determination. Under these conditions, the performance of the biosensors has been tested. The residual standard deviation (RSD) of the slopes of different calibration Curves was 9.77% (n=4 and alpha=0.05) for the reproducibility and 7.73% (n=4 and alpha=0.05) in the case of the repeatability. An average limit of detection of 9.81 x 10(-6) M (alpha=beta=0.05) was obtained. The biosensors have been finally applied to the determination of LEV in complex matrices, Such as pharmaceutical drugs and spiked human plasma samples, yielding Successful results. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:306 / 309
页数:4
相关论文
共 32 条
[21]   A micromethod for the determination of the new antiepileptic drug levetiracetam (ucb LO59) in serum or plasma by high performance liquid chromatography [J].
Ratnaraj, N ;
Doheny, HC ;
Patsalos, PN .
THERAPEUTIC DRUG MONITORING, 1996, 18 (02) :154-157
[22]   Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode [J].
Razola, SS ;
Ruiz, BL ;
Diez, NM ;
Mark, HB ;
Kauffmann, JM .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :921-928
[23]   A novel method for the anodic stripping voltammetry determination of Sb(III) using silver nanoparticle-modified screen-printed electrodes [J].
Renedo, Olga Dominguez ;
Martinez, M. Julia Arcos .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (04) :820-826
[24]  
Rousseeuw P.J., 1989, Robust Regression and Outlier Detection, DOI [10.2307/2982847, DOI 10.2307/2982847]
[25]   Solid-State valproate ion selective sensor based on conducting polypyrrole films for determination of valproate in pharmaceutical preparations [J].
Sabah, S ;
Aghamohammadi, M ;
Alizadeh, N .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) :489-496
[26]   DETARCHI - A PROGRAM FOR DETECTION LIMITS WITH SPECIFIED ASSURANCE PROBABILITIES AND CHARACTERISTIC CURVES OF DETECTION [J].
SARABIA, L ;
ORTIZ, MC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (01) :1-6
[27]  
Serra B, 2001, ELECTROANAL, V13, P693, DOI 10.1002/1521-4109(200105)13:8/9<693::AID-ELAN693>3.0.CO
[28]  
2-3
[29]   Analysis of the antiepileptic drug keppra by capillary electrophoresis [J].
Shihabi, ZK ;
Oles, K ;
Hinsdale, M .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1004 (1-2) :9-12
[30]  
*STAT GRAPH CORP, 1994, STATGRAPHICS PLUS WI