Respiration tracking in radiosurgery

被引:253
作者
Schweikard, A [1 ]
Shiomi, H
Adler, J
机构
[1] Med Univ Lubeck, D-23538 Lubeck, Germany
[2] Osaka Univ, Grad Sch Med, Div Multidisciplinary Radiotherapy, Osaka, Japan
[3] Stanford Univ, Med Ctr, Stanford, CA 94305 USA
关键词
whole body radiosurgery; respiration tracking; soft-tissue navigation;
D O I
10.1118/1.1774132
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion is difficult to compensate for with conventional radiotherapy systems. An accurate tracking method for following the motion of the tumor is of considerable clinical relevance. We investigate methods to compensate for respiratory motion using robotic radiosurgery. In this system the therapeutic beam is moved by a robotic arm, and follows the moving target through a combination of infrared tracking and synchronized x-ray imaging. Infrared emitters are used to record the motion of the patient's skin surface. The position of internal gold fiducials is computed repeatedly during treatment, via x-ray image processing. We correlate the motion between external and internal markers. From this correlation model we infer the placement of the internal target during time intervals where no x-ray images are taken. Fifteen patients with lung tumors have recently been treated with a fully integrated system implementing this new method. The clinical trials confirm our hypothesis that internal motion and external motion are indeed correlated. In a preliminar study we have extended our work to tracking without implanted fiducials, based on algorithms for computing deformation motions and digitally reconstructed radiographs. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:2738 / 2741
页数:4
相关论文
共 9 条
[1]  
KUBO HD, 1996, PHYS MED BIOL, V41, P93
[2]  
MORRILL SM, 1996, MED PHYS, V23, P1083
[3]   Planning for camera-guided robotic radiosurgery [J].
Schweikard, A ;
Bodduluri, M ;
Adler, JR .
IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1998, 14 (06) :951-962
[4]  
SCHWEIKARD A, 2000, SPECIAL ISSUE PLANNI
[5]  
SONTAG MR, 1996, MED PHYS, V23, P1082
[6]   Lung cancer: Intermittent irradiation synchronized with respiratory motion - Results of a pilot study [J].
Tada, T ;
Minakuchi, K ;
Fujioka, T ;
Sakurai, M ;
Koda, M ;
Kawase, I ;
Nakajima, T ;
Nishioka, M ;
Tonai, T ;
Kozuka, T .
RADIOLOGY, 1998, 207 (03) :779-783
[7]   Conformal intensity-modulated radiotherapy (IMRT) delivered by robotic linac - conformality versus efficiency of dose delivery [J].
Webb, S .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07) :1715-1730
[8]  
WEBB S, 1993, PHYS 3 DIMENSIONAL
[9]   LINEAR-ACCELERATOR AS A NEUROSURGICAL TOOL FOR STEREOTACTIC RADIOSURGERY [J].
WINSTON, KR ;
LUTZ, W .
NEUROSURGERY, 1988, 22 (03) :454-464