MARGINAL ADAPTATION OF THREE DIFFERENT ZIRCONIUM DIOXIDE THREE-UNIT FIXED DENTAL PROSTHESES

被引:101
作者
Att, Wael [1 ]
Komine, Futoshii [2 ]
Gerds, Thomas [3 ]
Strub, Joerg Rudolf [1 ]
机构
[1] Univ Freiburg, Dept Prosthodont, Sch Dent, D-79106 Freiburg, Germany
[2] Nihon Univ, Sch Dent, Dept Fixed Prosthodont, Tokyo 102, Japan
[3] Univ Copenhagen, Dept Biostat, DK-1168 Copenhagen, Denmark
关键词
PARTIAL DENTURES; CERAMIC MATERIALS; FILM THICKNESS; CAD/CAM; FIT; ACCURACY; STRENGTH; FRAMEWORKS; PRECISION; COPINGS;
D O I
10.1016/S0022-3913(09)60047-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Marginal adaptation is important for the long-term success of dental restorations. Data on the marginal discrepancy of zirconia-based fixed dental prostheses made with different computer-aided design/computer-aided manufacturing technology is needed. Purpose. The purpose of this study was to evaluate the marginal adaptation of different zirconia 3-unit fixed dental prostheses at different fabrication stages and after artificial aging. Material and methods. Twenty-four zirconia 3-unit fixed dental prostheses (DCS, Procera, and VITA YZ-Cerec; n=8) were fabricated using different manufacturing systems and conventionally cemented with glass ionomer cement on human teeth. Each group was aged in a masticatory simulator with thermal cycling. The marginal gaps were examined on epoxy replicas for frameworks and for restorations before and after cementation, and after masticatory simulation, at x250 magnification. Marginal adaptation was assessed using geometric means of the marginal gap values with 95% confidence intervals. Differences between the manufacturing systems and the effect of artificial aging were tested using repeated-measures ANOVA and post hoc paired and unpaired t tests with Bonferroni-Holm correction (alpha=.05). Results. The geometric mean (95% confidence limits) marginal gap values (mu m) for frameworks and for restorations before cementation, after cementation, and after masticatory simulation were, respectively: DCS: 86 (80-93), 86 (8390), 86 (78-94), and 84 (79-90); Procera: 82 (74-89), 89 (81-97), 89 (84-95), and 88 (82-94); and VITA YZ-Cerec: 64 (57-72), 67 (61-77), 76 (71-82), and 78 (76-80). The repeated-measures ANOVA showed significant group and stage effects (P<.05). Group VITA YZ-Cerec showed significantly smaller marginal gap values than groups DCS and Procera at framework (P<.05) and before-cementation (P<.05) stages. The VITA YZ-Cerec group showed significantly smaller marginal gap values than the Procera group after cementation (P<.05). The marginal gap values between different stages were not significantly different for all groups (P>.05). Conclusions. The marginal accuracy of zirconia fixed dental prostheses is influenced by manufacturing technique. (J Prosthet Dent 2009;101:239-247)
引用
收藏
页码:239 / 247
页数:9
相关论文
共 45 条
[11]  
Fransson B, 1985, Dent Mater, V1, P197, DOI 10.1016/S0109-5641(85)80019-1
[12]   MARGINS OF COMPLETE CROWNS - LITERATURE-REVIEW [J].
GARDNER, FM .
JOURNAL OF PROSTHETIC DENTISTRY, 1982, 48 (04) :396-400
[13]   Determination of the minimum number of marginal gap measurements required for practical in vitro testing [J].
Groten, M ;
Axmann, D ;
Pröbster, L ;
Weber, H .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (01) :40-49
[14]   Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics [J].
Guazzato, M ;
Albakry, M ;
Ringer, SP ;
Swain, MV .
DENTAL MATERIALS, 2004, 20 (05) :449-456
[15]   CONSIDERATIONS IN MEASUREMENT OF MARGINAL FIT [J].
HOLMES, JR ;
BAYNE, SC ;
HOLLAND, GA ;
SULIK, WD .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (04) :405-408
[16]  
Kern M, 2005, QUINTESSENCE INT, V36, P141
[17]   Wear of composite resin veneering materials in a dual-axis chewing simulator [J].
Kern, M ;
Strub, JR ;
Lü, XY .
JOURNAL OF ORAL REHABILITATION, 1999, 26 (05) :372-378
[18]   Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures [J].
Knoernschild, KL ;
Campbell, SD .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (05) :492-498
[19]   Clinical marginal and internal gaps of Procera AllCeram crowns [J].
Kokubo, Y ;
Ohkubo, C ;
Tsumita, M ;
Miyashita, A ;
Von Steyern, PV ;
Fukushima, S .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (07) :526-530
[20]   Influence of framework configuration on the marginal adaptation of zirconium dioxide ceramic anterior four-unit frameworks [J].
Komine, F ;
Gerds, T ;
Witkowski, S ;
Strub, JR .
ACTA ODONTOLOGICA SCANDINAVICA, 2005, 63 (06) :361-366