Supported liquid membrane enrichment combined with atomic absorption spectrometry for the determination of lead in urine

被引:41
作者
Djane, NK [1 ]
Bergdahl, IA [1 ]
Ndungu, K [1 ]
Schutz, A [1 ]
Johansson, G [1 ]
Mathiasson, L [1 ]
机构
[1] UNIV LUND HOSP,DEPT OCCUPAT & ENVIRONM MED,S-22185 LUND,SWEDEN
关键词
lead; urine; supported liquid membranes; atomic absorption spectrometry; inductively coupled plasma mass spectrometry; carry-over effects;
D O I
10.1039/a702340e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Supported liquid membrane (SLM) methodology was used for sample clean-up and enrichment of lead in urine prior to determination by AAS, Lead ions at pH 3 were extracted across a membrane solution containing 40% m/m di-2-ethylhexylphosphoric acid dissolved in kerosene and back-extracted into an acceptor solution of 1 mol l(-1) nitric acid, The mechanism of mass transfer is a proton gradient across the membrane, The concentration range investigated was between 5 and 80 ng ml(-1) and the extraction time was varied between 0.5 and 4 h, leading to enrichment factors of up to 200, The extraction efficiency was about 95%, The detection limit, expressed as 3 sigma of five replicate determinations, using a 45 min enrichment of a urine sample low in lead, was 0.1 and 6.0 mu g l(-1) for ETAAS, and FAAS respectively, The results obtained by the developed method agreed with those obtained by direct ICP-MS determinations for reference urine samples and samples from occupationally lead-exposed workers, The linear correlation coefficient was 0.97, the slope of the regression line was 1.06 and the intercept was -0.37 mu g l(-1), The 95% confidence intervals for the slope and the intercept were 0.95 to 1.18 and -3.9 to 3.1, respectively, The results at the 95% confidence level for reference urine material mere of 91 +/- 1.5 and 92 +/- 2.0 mu g l(-1) for ICP-MS and SLM-AAS, respectively, which agreed well with the recommended value of 90 mu g l(-1) (range 83-97 mu g l(-1)).
引用
收藏
页码:1073 / 1077
页数:5
相关论文
共 25 条
[1]   CHEMICALLY MODIFIED ELECTRODE FOR THE SIMULTANEOUS DETERMINATION OF TRACE-METALS AND SPECIATION ANALYSIS [J].
AGRAZ, R ;
SEVILLA, MT ;
HERNANDEZ, L .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :205-212
[2]   VOLTAMMETRIC DETERMINATION OF CADMIUM ON A CARBON PASTE ELECTRODE MODIFIED WITH A CHELATING RESIN [J].
AGRAZ, R ;
SEVILLA, MT ;
PINILLA, JM ;
HERNANDEZ, L .
ELECTROANALYSIS, 1991, 3 (4-5) :393-397
[3]  
[Anonymous], 1994, STAT ANAL CHEM
[4]  
BERGDAHL IA, IN PRESS SCAND J WOR
[5]  
BERKOW R, 1992, MERCK MANUAL DIAGNOS
[6]  
BO-XING X, 1985, Talanta, V32, P1016, DOI 10.1016/0039-9140(85)80227-7
[7]   SAMPLING AND ANALYTICAL METHODS FOR THE DETERMINATION OF COPPER, CADMIUM, ZINC, AND NICKEL AT THE NANOGRAM PER LITER LEVEL IN SEA-WATER [J].
BRULAND, KW ;
FRANKS, RP ;
KNAUER, GA ;
MARTIN, JH .
ANALYTICA CHIMICA ACTA, 1979, 105 (01) :233-245
[8]   DETERMINATION OF SOME METAL-IONS USING LICHEN-MODIFIED CARBON PASTE ELECTRODES [J].
CONNOR, M ;
DEMPSEY, E ;
SMYTH, MR ;
RICHARDSON, DHS .
ELECTROANALYSIS, 1991, 3 (4-5) :331-336
[9]   Supported liquid membrane enrichment using an organophosphorus extractant for analytical trace metal determinations in river waters [J].
Djane, NK ;
Ndungu, K ;
Malcus, F ;
Johansson, G ;
Mathiasson, L .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (7-8) :822-827
[10]  
DOUGLAS DJ, 1985, PROG ANAL ATOM SPECT, V8, P1