The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system

被引:226
作者
Ishibashi, Y [1 ]
Rudy, TW [1 ]
Livesay, GA [1 ]
Stone, JD [1 ]
Fu, FH [1 ]
Woo, SLY [1 ]
机构
[1] UNIV PITTSBURGH,MED CTR,MUSCULOSKELETAL RES CTR,DEPT ORTHOPAED SURG,PITTSBURGH,PA 15213
来源
ARTHROSCOPY | 1997年 / 13卷 / 02期
关键词
anterior cruciate ligament; reconstruction; graft fixation; knee stability; robotics;
D O I
10.1016/S0749-8063(97)90152-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Despite its current popularity and relative success, endoscopic reconstruction of the anterior cruciate ligament (ACL) using a bone-patellar tendon-bone (BPTB) graft has not yet been perfected. Using a recently developed robotic/UFS testing system, we assessed the overall stability of porcine knees following ACL reconstruction with different sites of tibial graft fixation--proximal, central, and distal. Testing of the intact knee was performed first to determine the normal anterior-posterior (A-P) displacements and in situ forces of the ACL under 110 N of anterior tibial loading at 30 degrees, 60 degrees, and 90 degrees of knee flexion, The knee was then reconstructed with a BPTB autograft, and the distal end of the graft was fixed sequentially at three different locations in each specimen--proximal, central, distal. A-P testing was repeated for each fixation site, and the resulting knee kinematics and the in situ forces of the grafts were compared to the intact case. The site of tibial fixation was demonstrated to have a significant effect on the resulting anterior displacement and internal rotation of the tibia as well as the in situ forces of the graft. Proximal fixation produced the most stable knee (A-P displacements reduced to 120% of intact at 30 degrees and 170% at 90 degrees), becoming significantly less stable with more distal fixation. These results suggest that proximal graft fixation may provide the most acute stability of the reconstructed knee.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 22 条
[11]  
Miyasaka K., 1991, AM J KNEE SURG, V4, P3
[12]   Isometry testing for anterior cruciate ligament reconstruction revisited [J].
Morgan, CD ;
Kalmam, VR ;
Grawl, DM .
ARTHROSCOPY, 1995, 11 (06) :647-659
[13]  
MORGAN CD, 1994, AANA SPEC DAY M, P116
[14]   BIOMECHANICAL ANALYSIS OF HUMAN LIGAMENT GRAFTS USED IN KNEE-LIGAMENT REPAIRS AND RECONSTRUCTIONS [J].
NOYES, FR ;
BUTLER, DL ;
GROOD, ES ;
ZERNICKE, RF ;
HEFZY, MS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (03) :344-352
[15]   FUNCTIONAL-ANATOMY OF THE ANTERIOR CRUCIATE LIGAMENT AND A RATIONALE FOR RECONSTRUCTION [J].
ODENSTEN, M ;
GILLQUIST, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (02) :257-262
[16]  
ODENSTEN M, 1986, CLIN ORTHOP RELAT R, V213, P154
[17]  
PAULOS LE, 1991, CLIN SPORT MED, V10, P469
[18]   A combined robotic/universal force sensor approach to determine in situ forces of knee ligaments [J].
Rudy, TW ;
Livesay, GA ;
Woo, SLY ;
Fu, FH .
JOURNAL OF BIOMECHANICS, 1996, 29 (10) :1357-1360
[19]   GRAFT TUNNEL MISMATCH IN ENDOSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION - A NEW TECHNIQUE OF INTRAARTICULAR MEASUREMENT AND MODIFIED GRAFT HARVESTING [J].
SHAFFER, B ;
GOW, W ;
TIBONE, JE .
ARTHROSCOPY, 1993, 9 (06) :633-646
[20]   TENSILE PROPERTIES OF THE HUMAN FEMUR-ANTERIOR CRUCIATE LIGAMENT-TIBIA COMPLEX - THE EFFECTS OF SPECIMEN AGE AND ORIENTATION [J].
WOO, SLY ;
HOLLIS, JM ;
ADAMS, DJ ;
LYON, RM ;
TAKAI, S .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1991, 19 (03) :217-225