Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: Comparison to IVUS

被引:183
作者
Pohle, Karsten
Achenbach, Stephan
MacNeill, Briain
Ropers, Dieter
Ferencik, Maros
Moselewski, Fabian
Hoffmann, Udo
Brady, Thomas J.
Jang, Ik-Kyung
Daniel, Werner G.
机构
[1] Univ Erlangen Nurnberg, Dept Internal Med, Erlangen, Germany
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
关键词
imaging; computed tomography; plaque; atherosclerosis;
D O I
10.1016/j.atherosclerosis.2006.01.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Multi-detector row Computed Tomography (MDCT) permits non-invasive visualization of the coronary arteries. The ability to visualize and, with limitations, to characterize non-calcified coronary atherosclerotic plaque has been described. We investigated the CT attenuation of non-calcified plaques as determined by 16-slice MDCT in comparison to intravascular ultrasound (IVUS). Methods and results: Thirty-two patients were investigated by contrast-enhanced 16-slice CT. In addition, IVUS of one coronary artery (motorized pullback) was performed (LM+LAD: 22, LM+LCX: 4, RCA: 6). At 252 sites within the coronary system, in which non-calcified atherosclerotic plaque could be identified both in MDCT and IVUS, the CT attenuation within the plaque was measured using a centrally placed region of interest and correlated to the appearance of the plaque in IVUS at the corresponding location. The mean CT attenuation within plaque that corresponded to hyper-echogenic appearance in IVUS was 121 +/- 34 HU (n = 76). The mean CT attenuation within plaque that corresponded to hypo-echogenic appearance was 58 +/- 43 HU (n = 176, p < 0.001). However, there was substantial overlap of the density values measured by MDCT in the two groups. Conclusions: A significant difference of the mean CT attenuation within atherosclerotic lesions of hypo-echogenic and hyper-echogenic appearance in IVUS could be observed. However, we observed substantial overlap of attenuation values between plaque types so that the differentiation of "vulnerable" and "stable" plaques based on their CT attenuation is doubtful. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:174 / 180
页数:7
相关论文
共 25 条
[1]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[2]  
ACHENBACH S, 2005, EUR HEART J 0527
[3]   Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT [J].
Becker, CR ;
Nikolaou, K ;
Muders, M ;
Babaryka, G ;
Crispin, A ;
Schoepf, UJ ;
Loehrs, U ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2003, 13 (09) :2094-2098
[4]   Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography [J].
Cademartiri, F ;
Mollet, NR ;
Runza, G ;
Bruining, N ;
Hamers, R ;
Somers, P ;
Knaapen, M ;
Verheye, S ;
Midiri, M ;
Krestin, GP ;
de Feyter, PJ .
EUROPEAN RADIOLOGY, 2005, 15 (07) :1426-1431
[5]   Characterization of vulnerable nonstenotic plaque with 16-slice computed tomography compared with intravascular sound [J].
Caussin, C ;
Ohanessian, A ;
Ghostine, S ;
Jacq, L ;
Lancelin, B ;
Dambrin, G ;
Sigal-Cinqualbre, A ;
Angel, CY ;
Paul, JF .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (01) :99-104
[6]  
Estes JM, 1998, J CARDIOVASC SURG, V39, P527
[7]  
Gotsman MS, 1997, ADV EXP MED BIOL, V430, P197
[8]  
HIRO T, 1996, AM J CARD IMAGING, V10, P128
[9]   Noninvasive coronary angiography with multislice computed tomography [J].
Hoffmann, MHK ;
Shi, HS ;
Schmitz, BL ;
Schmid, FT ;
Lieberknecht, ML ;
Schulze, R ;
Ludwig, B ;
Kroschel, U ;
Jahnke, N ;
Haerer, W ;
Brambs, HJ ;
Aschoff, AJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (20) :2471-2478
[10]   Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643