3D MRA coronary axis determination using a minimum cost path approach

被引:56
作者
Wink, O
Frangi, AF
Verdonck, B
Viergever, MA
Niessen, WJ
机构
[1] UMC Utrecht, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Philips Med Syst BV, EasyVis Adv Dev, Best, Netherlands
关键词
3D coronary MRA; central vessel axis; vessel visualization; minimum cost path; quantitative coronary analysis;
D O I
10.1002/mrm.10164
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method is introduced to automatically find the coronary axis based on two or more user-defined points, even in the presence of a severe stenosis. The coronary axis is determined by finding a minimum cost path (MCP) in a feature image in which the tubular-like structures are enhanced. The results of the proposed method were compared with manually drawn central axes to estimate the accuracy. In 32 3D TFE-EPI acquisitions of patients and volunteers, 14 right coronary arteries (RCAs), 15 left anterior descending arteries (LADs), and eight left circumflex arteries (LCXs) were manually tracked twice by two operators to determine a reference axis and to assess the inter- and intra-user variability. On average, the maximum distance to the reference axis, based on only two user-defined points, is less than 1.5 mm; the average distance is around 0.65 mm, which is less than the average in-plane resolution. The results of the method are comparable to those of the manual operators.
引用
收藏
页码:1169 / 1175
页数:7
相关论文
共 36 条
[1]  
AMINI AA, 1996, P WORKSH MATH METH B, P131
[2]  
Avants BB, 2000, LECT NOTES COMPUT SC, V1935, P707
[3]  
Botnar RM, 1999, JMRI-J MAGN RESON IM, V10, P821, DOI 10.1002/(SICI)1522-2586(199911)10:5<821::AID-JMRI29>3.0.CO
[4]  
2-7
[5]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[6]   Buckets, heaps, lists, and monotone priority queues [J].
Cherkassky, BV ;
Goldberg, AV ;
Silverstein, C .
SIAM JOURNAL ON COMPUTING, 1999, 28 (04) :1326-1346
[7]   3D MR coronary artery segmentation [J].
Cline, HE ;
Thedens, DR ;
Irarrazaval, P ;
Meyer, CH ;
Hu, BS ;
Nishimura, DG ;
Ludke, S .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (05) :697-702
[8]  
Cline HE, 2000, MAGNET RESON MED, V43, P892, DOI 10.1002/1522-2594(200006)43:6<892::AID-MRM16>3.0.CO
[9]  
2-Q
[10]   Fast extraction of minimal paths in 3D images and applications to virtual endoscopy [J].
Deschamps, T ;
Cohen, LD .
MEDICAL IMAGE ANALYSIS, 2001, 5 (04) :281-299