Everolimus-eluting bioresorbable vascular scaffolds for treatment of patients presenting with ST-segment elevation myocardial infarction: BVS STEMI first study

被引:102
作者
Diletti, Roberto [1 ]
Karanasos, Antonios [1 ]
Muramatsu, Takashi [1 ]
Nakatani, Shimpei [1 ]
Van Mieghem, Nicolas M. [1 ]
Onuma, Yoshinobu [1 ]
Nauta, Sjoerd T. [1 ]
Ishibashi, Yuki [1 ]
Lenzen, Mattie J. [1 ]
Schultz, Carl [1 ]
Regar, Evelyn [1 ]
de Jaegere, Peter P. [1 ]
Serruys, Patrick W. [1 ]
Zijlstra, Felix [1 ]
van Geuns, Robert Jan [1 ]
机构
[1] Erasmus MC, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
关键词
Bioresorbable vascular scaffolds; ST-segment elevation myocardial infarction; Optical coherence tomography; OPTICAL COHERENCE TOMOGRAPHY; CORONARY STENT SYSTEM; BARE-METAL STENTS; PERCUTANEOUS CORONARY; CLINICAL-APPLICATIONS; ABSORB; IMPLANTATION; OUTCOMES; 2ND-GENERATION; REVASCULARIZATION;
D O I
10.1093/eurheartj/eht546
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We evaluated the feasibility and the acute performance of the everolimus-eluting bioresorbable vascular scaffolds (BVS) for the treatment of patients presenting with ST-segment elevation myocardial infarction (STEMI). Methods and results The present investigation is a prospective, single-arm, single-centre study, reporting data after the BVS implantation in STEMI patients. Quantitative coronary angiography and optical coherence tomography (OCT) data were evaluated. Clinical outcomes are reported at the 30-day follow-up. The intent-to-treat population comprises a total of 49 patients. The procedural success was 97.9%. Pre-procedure TIMI-flow was 0 in 50.0% of the patients; after the BVS implantation, a TIMI-flow III was achieved in 91.7% of patients and the post-procedure percentage diameter stenosis was 14.7+/-8.2%. No patients had angiographically visible residual thrombus at the end of the procedure. Optical coherence tomography analysis performed in 31 patients showed that the post-procedure mean lumen area was 8.02+/-1.92 mm(2), minimum lumen area 5.95+/-1.61 mm(2), mean incomplete scaffold apposition area 0.118+/-0.162 mm(2), mean intraluminal defect area 0.013+/-0.017 mm(2), and mean percentage malapposed struts per patient 2.80+/-3.90%. Scaffolds with >5% malapposed struts were 7. At the 30-day follow-up, target-lesion failure rate was 0%. Non-target-vessel revascularization and target-vessel myocardial infarction (MI) were reported. Anon-target-vessel non-Q-wave MI occurred. No cases of cardiac death or scaffold thrombosis were observed. Conclusion In the present series, the BVS implantation in patients presenting with acute MI appeared feasible, with high rate of final TIMI-flow III and good scaffold apposition. Larger studies are currently needed to confirm these preliminary data.
引用
收藏
页码:777 / +
页数:12
相关论文
共 38 条
[31]   A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods [J].
Serruys, Patrick W. ;
Ormiston, John A. ;
Onuma, Yoshinobu ;
Regar, Evelyn ;
Gonzalo, Nieves ;
Garcia-Garcia, Hector M. ;
Nieman, Koen ;
Bruining, Nico ;
Dorange, Cecile ;
Miquel-Hebert, Karine ;
Veldhof, Susan ;
Webster, Mark ;
Thuesen, Leif ;
Dudek, Dariusz .
LANCET, 2009, 373 (9667) :897-910
[32]   Angiographic stent thrombosis after routine use of drug-eluting stents in ST-segment elevation myocardial infarction - The importance of thrombus burden [J].
Sianos, Georgios ;
Papafaklis, Michail I. ;
Daemen, Joost ;
Vaina, Sofia ;
van Mieghem, Carlos A. ;
van Domburg, Ron T. ;
Michalis, Lampros K. ;
Serruys, Patrick W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (07) :573-583
[33]   Sirolimus-eluting versus uncoated stents in acute myocardial infarction [J].
Spaulding, Christian ;
Henry, Patrick ;
Teiger, Emmanuel ;
Beatt, Kevin ;
Bramucci, Ezio ;
Carrie, Didier ;
Slama, Michel S. ;
Merkely, Bela ;
Erglis, Andrejs ;
Margheri, Massimo ;
Varenne, Olivier ;
Cebrian, Ana ;
Stoll, Hans-Peter ;
Snead, David B. ;
Bode, Christoph .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (11) :1093-1104
[34]   Prospective, Randomized, Multicenter Evaluation of a Polyethylene Terephthalate Micronet Mesh-Covered Stent (MGuard) in ST-Segment Elevation Myocardial Infarction The MASTER Trial [J].
Stone, Gregg W. ;
Abizaid, Alexandre ;
Silber, Sigmund ;
Dizon, Jose M. ;
Merkely, Bela ;
Costa, Ricardo A. ;
Kornowski, Ran ;
Abizaid, Andrea ;
Wojdyla, Roman ;
Maehara, Akiko ;
Dressler, Ovidiu ;
Brener, Sorin J. ;
Bar, Eli ;
Dudek, Dariusz .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (19) :1975-1984
[35]   Paclitaxel-Eluting Stents versus Bare-Metal Stents in Acute Myocardial Infarction. [J].
Stone, Gregg W. ;
Lansky, Alexandra J. ;
Pocock, Stuart J. ;
Gersh, Bernard J. ;
Dangas, George ;
Wong, S. Chiu ;
Witzenbichler, Bernhard ;
Guagliumi, Giulio ;
Peruga, Jan Z. ;
Brodie, Bruce R. ;
Dudek, Dariusz ;
Moeckel, Martin ;
Ochala, Andrzej ;
Kellock, Alison ;
Parise, Helen ;
Mehran, Roxana .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (19) :1946-1959
[36]   Guidelines on myocardial revascularization The Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) [J].
Wijns, William ;
Kolh, Philippe .
EUROPEAN HEART JOURNAL, 2010, 31 (20) :2501-2555
[37]   Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography Studies A Report From the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation [J].
Tearney, Guillermo J. ;
Regar, Evelyn ;
Akasaka, Takashi ;
Adriaenssens, Tom ;
Barlis, Peter ;
Bezerra, Hiram G. ;
Bouma, Brett ;
Bruining, Nico ;
Cho, Jin-man ;
Chowdhary, Saqib ;
Costa, Marco A. ;
de Silva, Ranil ;
Dijkstra, Jouke ;
Di Mario, Carlo ;
Dudeck, Darius ;
Falk, Erlin ;
Feldman, Marc D. ;
Fitzgerald, Peter ;
Garcia, Hector ;
Gonzalo, Nieves ;
Granada, Juan F. ;
Guagliumi, Giulio ;
Holm, Niels R. ;
Honda, Yasuhiro ;
Ikeno, Fumiaki ;
Kawasaki, Masanori ;
Kochman, Janusz ;
Koltowski, Lukasz ;
Kubo, Takashi ;
Kume, Teruyoshi ;
Kyono, Hiroyuki ;
Lam, Cheung Chi Simon ;
Lamouche, Guy ;
Lee, David P. ;
Leon, Martin B. ;
Maehara, Akiko ;
Manfrini, Olivia ;
Mintz, Gary S. ;
Mizuno, Kyiouchi ;
Morel, Marie-angele ;
Nadkarni, Seemantini ;
Okura, Hiroyuki ;
Otake, Hiromasa ;
Pietrasik, Arkadiusz ;
Prati, Francesco ;
Raeber, Lorenz ;
Radu, Maria D. ;
Rieber, Johannes ;
Riga, Maria ;
Rollins, Andrew .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (12) :1058-1072
[38]   Self-Expanding Versus Balloon-Expandable Stents in Acute Myocardial Infarction: Results From the APPOSITION II Study Self-Expanding Stents in ST-Segment Elevation Myocardial Infarction [J].
van Geuns, Robert-Jan ;
Tamburino, Corrado ;
Fajadet, Jean ;
Vrolix, Mathias ;
Witzenbichler, Bernhard ;
Eeckhout, Eric ;
Spaulding, Christian ;
Reczuch, Krzysztof ;
La Manna, Alessio ;
Spaargaren, Rene ;
Garcia-Garcia, Hector M. ;
Regar, Evelyn ;
Capodanno, Davide ;
Van Langenhove, Glenn ;
Verheye, Stefan .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (12) :1209-1219