Case Series Using the ROTAFLOW System as a Temporary Right Ventricular Assist Device after HeartMate II Implantation

被引:12
作者
Khani-Hanjani, Abbas [1 ]
Loor, Gabriel [1 ]
Chamogeorgakis, Themistokles [2 ]
Shafii, Alexis [2 ]
Mountis, Maria [1 ]
Hanna, Mazen [1 ]
Soltesz, Edward [1 ]
Gonzalez-Stawinski, Gonzalo V. [2 ]
机构
[1] Cleveland Clin, Dept Thorac & Cardiovasc Surg & Cardiovasc Med, Cleveland, OH 44106 USA
[2] Baylor Univ, Med Ctr, Dept Cardiac Surg, Dallas, TX 75246 USA
关键词
HeartMate II; ROTAFLOW; RVAD; right ventricular dysfunction; MECHANICAL CIRCULATORY SUPPORT; RISK SCORE; FAILURE; EXPERIENCE; ECMO;
D O I
10.1097/MAT.0b013e318291d133
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to investigate the outcomes of using the ROTAFLOW as a temporary right ventricular assist device (RVAD) support in patients who develop right ventricular dysfunction (RVD) at the time of left ventricular assist device (LVAD) implantation with the HeartMate (HM) II. We conducted a retrospective chart review of patients in whom the ROTAFLOW system was used for RV support during HM II implantation from October 2009 to September 2011. Twelve patients received a ROTAFLOW as an RVAD at the time of HM II implantation; 83% had preoperative echocardiography evidence of either moderate or severe RVD. The most common complications in the postoperative period were the need for tracheostomy because of respiratory failure (45%) and mediastinal bleeding requiring exploration (36%). Ninety-one percent of patients survived to discharge, and all were alive at 1 year follow-up. Our results show that temporary RVAD support with the ROTAFLOW system in the setting of RVD at the time of HM II implantation is feasible and effective.
引用
收藏
页码:456 / 460
页数:5
相关论文
共 15 条
[1]   Clinical Experience Using the Levitronix CentriMag System for Temporary Right Ventricular Mechanical Circulatory Support [J].
Bhama, Jay K. ;
Kormos, Robert L. ;
Toyoda, Yoshiya ;
Teuteberg, Jeffrey J. ;
McCurry, Kenneth R. ;
Siegenthaler, Michael P. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (09) :971-976
[2]  
Dang NC, 2006, J HEART LUNG TRANSPL, V25, P1, DOI 10.1016/j.healun.2005.07.008
[3]   Risk Factors Predictive of Right Ventricular Failure After Left Ventricular Assist Device Implantation [J].
Drakos, Stavros G. ;
Janicki, Lindsay ;
Horne, Benjamin D. ;
Kfoury, Abdallah G. ;
Reid, Bruce B. ;
Clayson, Stephen ;
Horton, Kenneth ;
Haddad, Francois ;
Li, Dean Y. ;
Renlund, Dale G. ;
Fisher, Patrick W. .
AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (07) :1030-1035
[4]   Risk Score Derived from Pre-operative Data Analysis Predicts the Need for Biventricular Mechanical Circulatory Support [J].
Fitzpatrick, J. Raymond, III ;
Frederick, John R. ;
Hsu, Vivian M. ;
Kozin, Elliott D. ;
O'Hara, Mary Lou ;
Howell, Elan ;
Dougherty, Deborah ;
McCormick, Ryan C. ;
Laporte, Carine A. ;
Cohen, Jeffrey E. ;
Southerland, Kevin W. ;
Howard, Jessica L. ;
Jessup, Mariell L. ;
Morris, Rohinton J. ;
Acker, Michael A. ;
Woo, Y. Joseph .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (12) :1286-1292
[5]   Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model [J].
Guan, Yulong ;
Su, Xiaowei ;
McCoach, Robert ;
Kunselman, Allen ;
El-Banayosy, Aly ;
Uendar, Akif .
PERFUSION-UK, 2010, 25 (02) :71-76
[6]   Successful Use of Temporary Right Ventricular Support to Avoid Implantation of Biventricular Long-Term Assist Device: A Transcutaneous Approach [J].
Haneya, Assad ;
Philipp, Alois ;
Diez, Claudius ;
Metterlein, Thomas ;
Puehler, Thomas ;
Hilker, Michael ;
Rupprecht, Leopold ;
Zausig, York ;
Schmid, Christof ;
Hirt, Stephan W. .
ASAIO JOURNAL, 2011, 57 (04) :274-277
[7]   Experience with the Jostra Rotaflow and QuadroxD oxygenator for ECMO [J].
Horton, S ;
Thuys, C ;
Bennett, M ;
Augustin, S ;
Rosenberg, M ;
Brizard, C .
PERFUSION-UK, 2004, 19 (01) :17-23
[8]   Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: Incidence, risk factors, and effect on outcomes [J].
Kormos, Robert L. ;
Teuteberg, Jeffrey J. ;
Pagani, Francis D. ;
Russell, Stuart D. ;
John, Ranjit ;
Miller, Leslie W. ;
Massey, Todd ;
Milano, Carmelo A. ;
Moazami, Nader ;
Sundareswaran, Kartik S. ;
Farrar, David J. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05) :1316-1324
[9]   Use of RotaFlow (MAQUET) for Temporary Right Ventricular Support During Implantation of HeartMate II Left Ventricular Assist Device [J].
Loor, Gabriel ;
Khani-Hanjani, Abbas ;
Gonzalez-Stawinski, Gonzalo V. .
ASAIO JOURNAL, 2012, 58 (03) :275-277
[10]   The right ventricular failure risk score - A pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates [J].
Matthews, Jennifer Cowger ;
Koelling, Todd M. ;
Pagani, Francis D. ;
Aaronson, Keith D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (22) :2163-2172