Incorporation of realistic delivery limitations into dynamic MLC treatment delivery

被引:53
作者
Litzenberg, DW [1 ]
Moran, JM [1 ]
Fraass, BA [1 ]
机构
[1] Univ Michigan, Med Ctr, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
关键词
DMLC; leaf sequencing; sliding window; system delay time; limiting velocity;
D O I
10.1118/1.1470499
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The clinical implementation of IMRT involves the use of a number of complex software-based systems, typically including an inverse planning system, a leaf sequencer, and a computer-controlled treatment delivery system. The inverse planning system determines the desired fluence patterns, the leaf sequencer translates those fluence maps into leaf trajectories, and the control system delivers those trajectories. While verification of intensity-modulated treatment fields has focused primarily on the dosimetric aspects of delivery, accurate delivery of the intended fluence distribution is dependent upon both the leaf sequencer and delivery control systems. Leaf sequencing algorithms typically do not incorporate many control system limitations, and this can lead to discrepancies between planned and delivered sequences. In this work. simple and complex fields were sequenced for the dynamic sliding window technique using different leaf speeds and tolerance settings to identify various limitations of the accelerator control system. This work was conducted on a Varian 2100 EX equipped with a Millennium 120 leaf MLC. The identified limitations were then incorporated into the sequencing algorithm using a limiting leaf velocity (less than the maximum leaf velocity), the leaf position tolerance, and the communications delay in the control system. Collision avoidance in leaf pairs was found to depend on a control system-enforced minimum gap between leaves and led to acceleration effects. By incorporating these effects into the leaf sequencing algorithm, dynamic sliding-window leaf sequences were produced which did not require beam interruptions or dose rate modulations for the parameter values used in calculating the sequence (dose rate, tolerance, leaf speed, and total monitor units). Incorporation of control system limitations into the leaf sequencing algorithm results in IMRT fields that are delivered with the prescribed constant close rate, require less time to deliver, and have well-defined, calculable transmission dose characteristics. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:810 / 820
页数:11
相关论文
共 15 条
[1]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[2]   The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy [J].
Dawson, LA ;
Brock, KK ;
Kazanjian, S ;
Fitch, D ;
McGinn, CJ ;
Lawrence, TS ;
Ten Haken, RK ;
Balter, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (05) :1410-1421
[3]   Leaf trajectory calculation for dynamic multileaf collimation to realize optimized fluence profiles [J].
Dirkx, MLP ;
Heijmen, BJM ;
van Santvoort, JPC .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) :1171-1184
[4]  
Ezzell G A, 2001, J Appl Clin Med Phys, V2, P138, DOI 10.1120/1.1386508
[5]   Calibration and quality assurance for rounded leaf-end MLC systems [J].
Graves, MN ;
Thompson, AV ;
Martel, MK ;
McShan, DL ;
Fraass, BA .
MEDICAL PHYSICS, 2001, 28 (11) :2227-2233
[6]  
Kessler M. L., 1999, International Journal of Radiation Oncology Biology Physics, V45, P187, DOI 10.1016/S0360-3016(99)90097-4
[7]  
Kim J, 1995, P 1995 INT ADV VIS S, P417
[8]  
LITZENBERG DL, IN PRESS J APPL CLIN
[9]   Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy [J].
LoSasso, T ;
Chui, CS ;
Ling, CC .
MEDICAL PHYSICS, 1998, 25 (10) :1919-1927
[10]  
MORAN JM, 2001, MED PHYS, V28, P1284