Accuracy of short-duration creatinine clearance determinations in predicting 24-hour creatinine clearance in critically ill and injured patients

被引:68
作者
Cherry, RA
Eachempati, SR
Hydo, L
Barie, PS
机构
[1] New York Presbyterian Hosp, Dept Surg, New York, NY 10021 USA
[2] Lincoln Med & Mental Hlth Ctr, Dept Surg, Bronx, NY 10451 USA
[3] Cornell Univ, Dept Surg, Weill Med Coll, New York, NY USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2002年 / 53卷 / 02期
关键词
D O I
10.1097/00005373-200208000-00013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. We hypothesized that measured 2-hour (CrCl2), 6-hour (CrCl6), and 16-hour (CrCl16) urine creatinine clearance accurately reflect measured (CrCl24meas) and calculated 24-hour CrCl (CrCl24(calc)) in critical illness. Methods: Urine was collected in consecutive specimens from 7 AM to 9 AM (CrCl2), 9 AM to 3 PM (CrCl6), and 3 PM to 7 AM (CrCl16) at surgical intensive care unit admission and weekly thereafter. CrCl2 and CrCl6 were added to obtain CrCl8 which was then added to CrCl16 to obtain CrCl24meas. CrCl24calc was estimated using the Cockcroft-Gault equation. Results: One hundred patients (45 with trauma) had 131 sets of CrCl2, CrCl6, and CrCl16. Trauma patients were younger; had a lower mean body surface area; and had higher CrCl2, CrCl6, and CrCl16 (all p<0.0001). Correlation percentages (r(2)) comparing CrCl2, CrCl6, CrCl8, CrCl16, and CrCl24(calc) with CrCl24meas in trauma patients were 0.597, 0.760, 0.815, 0.958, and 0.670, respectively. In nontrauma patients, r(2) values were 0.516, 0.693, 0.807, 0.946, and 0.649, respectively. Conclusion: CrCl2, CrCl6, and CrCl24calc are unreliable for clinical decision making. A minimum collection period of at least 8 hours is recommended for determination of urine creatinine clearance.
引用
收藏
页码:267 / 271
页数:5
相关论文
共 21 条
[11]   Can two-, four- or eight-hour urine collections after voluntary voiding be used instead of twenty-four-hour collections for the estimation of creatinine clearance in healthy subjects? [J].
Markantonis, SL ;
Agathokleous-Kioupaki, E .
PHARMACY WORLD & SCIENCE, 1998, 20 (06) :258-263
[12]   TABLES OF AVERAGE WEIGHT AND HEIGHT OF AMERICANS AGED 65 TO 94 YEARS - RELATIONSHIP OF WEIGHT AND HEIGHT TO SURVIVAL [J].
MASTER, AM ;
LASSER, RP ;
BECKMAN, G .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1960, 172 (07) :658-662
[13]  
MAWER GE, 1971, LANCET, V1, P975
[14]   THE EVALUATION OF CREATININE CLEARANCE IN SPINAL-CORD INJURY PATIENTS [J].
MOHLER, JL ;
BARTON, SD ;
BLOUIN, RA ;
COWEN, DL ;
FLANIGAN, RC .
JOURNAL OF UROLOGY, 1986, 136 (02) :366-369
[15]  
OCONNELL MB, 1993, PHARMACOTHERAPY, V13, P135
[16]   ONE-HOUR CREATININE CLEARANCE RATE IN HEALTHY MEN [J].
RICHARDSON, JA ;
PHILBIN, PE .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1971, 216 (06) :987-+
[17]   AGE-ADJUSTED STANDARDS FOR CREATININE CLEARANCE [J].
ROWE, JW ;
ANDRES, R ;
TOBIN, JD ;
NORRIS, AH ;
SHOCK, NW .
ANNALS OF INTERNAL MEDICINE, 1976, 84 (05) :567-569
[18]   CREATININE CLEARANCE FOR EARLY DETECTION OF POSTTRAUMATIC RENAL DYSFUNCTION [J].
SHIN, B ;
MACKENZIE, CF ;
HELRICH, M .
ANESTHESIOLOGY, 1986, 64 (05) :605-609
[19]   2-HOUR VERSUS 22-HOUR CREATININE CLEARANCE IN CRITICALLY ILL PATIENTS [J].
SLADEN, RN ;
ENDO, E ;
HARRISON, T .
ANESTHESIOLOGY, 1987, 67 (06) :1013-1016
[20]  
WILSON RF, 1979, ARCH SURG-CHICAGO, V114, P461