Dynamic field map estimation using a spiral-in/spiral-out acquisition

被引:83
作者
Sutton, BP [1 ]
Noll, DC [1 ]
Fessler, JA [1 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
image reconstruction; field inhomogeneity; functional MRI; iterative methods; spiral;
D O I
10.1002/mrm.20079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The long readout times of single-shot acquisitions and the high field strengths desired for functional MRI (fMRI) using blood oxygenation level-dependent (BOLD) contrast make functional scans sensitive to magnetic field inhomogeneity. If it is not corrected during image reconstruction, field inhomogeneity can cause geometric distortions in the images when Cartesian k-space trajectories are used or blurring with spiral acquisitions. Many traditional methods to correct for field inhomogeneity distortions rely on a static field map measured with the use of images that are themselves distorted. In this work, we employ a regularized least-squares approach to jointly estimate both the undistorted image and field map at each acquisition using a spiral-in/spiral-out pulse sequence. Simulation and phantom studies show that this method is accurate and stable over a time series. Human functional studies show that the jointly estimated field map may be more accurate than standard field map estimates in the presence of respiration-induced phase oscillations, leading to better detection of functional activation. The proposed method measures a dynamic field map that accurately tracks magnetic field drift and respiration-induced phase oscillations during the course of a functional study. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:1194 / 1204
页数:11
相关论文
共 21 条
[1]   PENALIZED WEIGHTED LEAST-SQUARES IMAGE-RECONSTRUCTION FOR POSITRON EMISSION TOMOGRAPHY [J].
FESSLER, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :290-300
[2]   Nonuniform fast Fourier transforms using min-max interpolation [J].
Fessler, JA ;
Sutton, BP .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2003, 51 (02) :560-574
[3]   Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts [J].
Glover, GH ;
Law, CS .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :515-522
[4]  
Haacke EM, 1999, MAGNETIC RESONANCE I
[5]  
Huber P. J., 1981, ROBUST STAT
[6]   Simulated phase evolution rewinding (SPHERE): A technique for reducing B-0 inhomogeneity effects in MR images [J].
Kadah, YM ;
Hu, XP .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :615-627
[7]   Multifrequency interpolation for fast off-resonance correction [J].
Man, LC ;
Pauly, JM ;
Macovski, A .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) :785-792
[8]  
Nayak KS, 2001, MAGNET RESON MED, V45, P521, DOI 10.1002/1522-2594(200103)45:3<521::AID-MRM1069>3.0.CO
[9]  
2-6
[10]  
Nayak KS, 2000, MAGNET RESON MED, V43, P151, DOI 10.1002/(SICI)1522-2594(200001)43:1<151::AID-MRM19>3.0.CO