Direct electron transfer between heme-containing enzymes and electrodes as basis for third generation biosensors

被引:481
作者
Gorton, L
Lindgren, A
Larsson, T
Munteanu, FD
Ruzgas, T
Gazaryan, I
机构
[1] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[2] Uppsala Univ, Dept Phys Chem, SE-75121 Uppsala, Sweden
[3] Moscow MV Lomonosov State Univ, Fac Chem, Dept Chem Enzymol, Moscow 119899, Russia
关键词
heme proteins; peroxidase; cellobiose dehydrogenase; direct electron transfer; biosensors;
D O I
10.1016/S0003-2670(99)00610-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Direct electron transfer (DET) between redox enzymes and electrodes found the basis for third generation biosensors. Recent investigations in the authors' laboratories on the bioelectrochemistry of heme-containing proteins and enzymes, primarily peroxidases, but also cellobiose dehydrogenase, will be reviewed. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:91 / 108
页数:18
相关论文
共 135 条
  • [31] Finklea HO, 1996, ELECTROANAL CHEM, V19, P109
  • [32] Crystal structure of horseradish peroxidase C at 2.15 angstrom resolution
    Gajhede, M
    Schuller, DJ
    Henriksen, A
    Smith, AT
    Poulos, TL
    [J]. NATURE STRUCTURAL BIOLOGY, 1997, 4 (12) : 1032 - 1038
  • [33] Gazarian IG, 1996, BIOCHEM J, V320, P369
  • [34] EFFECT OF SINGLE-POINT MUTATIONS PHE(41)-]HIS AND PHE(143)-]GLU ON FOLDING AND CATALYTIC PROPERTIES OF RECOMBINANT HORSERADISH-PEROXIDASE EXPRESSED IN ESCHERICHIA-COLI
    GAZARYAN, IG
    DOSEEVA, VV
    GALKIN, AG
    TISHKOV, VI
    [J]. FEBS LETTERS, 1994, 354 (03) : 248 - 250
  • [35] Enzyme-catalyzed direct electron transfer: Fundamentals and analytical applications
    Ghindilis, AL
    Atanasov, P
    Wilkins, E
    [J]. ELECTROANALYSIS, 1997, 9 (09) : 661 - 674
  • [36] CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS
    GORTON, L
    [J]. ELECTROANALYSIS, 1995, 7 (01) : 23 - 45
  • [37] AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE
    GORTON, L
    JONSSONPETTERSSON, G
    CSOREGI, E
    JOHANSSON, K
    DOMINGUEZ, E
    MARKOVARGA, G
    [J]. ANALYST, 1992, 117 (08) : 1235 - 1241
  • [38] AMPEROMETRIC GLUCOSE SENSORS BASED ON IMMOBILIZED GLUCOSE-OXIDIZING ENZYMES AND CHEMICALLY MODIFIED ELECTRODES
    GORTON, L
    BREMLE, G
    CSOREGI, E
    JONSSONPETTERSSON, G
    PERSSON, B
    [J]. ANALYTICA CHIMICA ACTA, 1991, 249 (01) : 43 - 54
  • [39] GORTON L, 1992, BIOELECTROANALYSIS, V2, P33
  • [40] DIRECT ELECTROCHEMISTRY OF PROTEINS AND ENZYMES
    GUO, LH
    HILL, HAO
    [J]. ADVANCES IN INORGANIC CHEMISTRY, 1991, 36 : 341 - 375