Pilot MR evaluation of pharmacokinetics and relaxivity of specific blood pool agents for MR angiography

被引:14
作者
Marchand, B
Douek, PC
Benderbous, S
Corot, C
Canet, E
机构
[1] Creatis UMR CNRS 5515, Lyon, France
[2] Guerbet Lab, Aulnay Sous Bois, France
关键词
experimental study; MR angiography; contrast agent;
D O I
10.1097/00004424-200001000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO evaluate the use of two new blood pool contrast agents (P760, P775) compared with a low-molecular-weight gadolinium chelate in MR angiography. METHODS. The r1 efficiency of P760 was evaluated in vitro at 1.5 T; 3D abdominal contrast-enhanced MR angiography with qualitative analysis was compared in four rabbits after injection of incremental doses of P760 and in one rabbit after Gd-DOTA, A dynamic MR study was performed using a 2D T1-weighted turbo-flash MR sequence after injection of P760, P775, and Gd-DOTA, Each compound was tested at equivalent doses in three rabbits to assess r1 efficiency. Quantitative analysis of signal intensity in the aorta, the inferior vena cava, the renal cortex, and the medulla was performed. RESULTS. In vitro, the r1 efficiency of P760 was 23.3 mmol(-1) . L . sec(-1) at 1.5 T. Injection of a dose of P760 10 times less than Gd-DOTA allowed similar vessel visualization, The signal intensity peak and first-pass contrast kinetics in the aorta and the inferior vena cava were similar with the three products. Compared with P760 and Gd-DOTA, P775 allowed a greater renal cortex signal intensity at the first pass and a faster decrease on delayed images. CONCLUSIONS; The superior r1 efficiency of P760 and P775 was confirmed in vitro and in vivo at 1.5 T compared with Gd-DOTA, and P775 proved to be a rapid-clearance blood pool agent.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 32 条
[1]   GD-DTPA-CASCADE-POLYMER - POTENTIAL BLOOD-POOL CONTRAST AGENT FOR MR-IMAGING [J].
ADAM, G ;
NEUERBURG, J ;
SPUNTRUP, E ;
MUHLER, A ;
SCHERER, K ;
GUNTHER, RW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) :462-466
[2]   MULTICENTER TRIAL TO EVALUATE VASCULAR MAGNETIC-RESONANCE ANGIOGRAPHY OF THE LOWER-EXTREMITY [J].
BAUM, RA ;
RUTTER, CM ;
SUNSHINE, JH ;
BLEBEA, JS ;
BLEBEA, J ;
CARPENTER, JP ;
DICKEY, KW ;
QUINN, SF ;
GOMES, AS ;
GRIST, TM ;
MCNEIL, BJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (11) :875-880
[3]   A NEW MACROMOLECULE AS A CONTRAST AGENT FOR MR-ANGIOGRAPHY - PREPARATION, PROPERTIES, AND ANIMAL STUDIES [J].
BOGDANOV, AA ;
WEISSLEDER, R ;
FRANK, HW ;
BOGDANOVA, AV ;
NOSSIF, N ;
SCHAFFER, BK ;
TSAI, E ;
PAPISOV, MI ;
BRADY, TJ .
RADIOLOGY, 1993, 187 (03) :701-706
[4]   Contrast-enhanced magnetic resonance angiography of peripheral vessels - Different contrast agent applications and sequence strategies: A review [J].
Boos, M ;
Lentschig, M ;
Scheffler, K ;
Bongartz, GM ;
Steinbrich, W .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :538-546
[5]   Evaluation of the effects of intravascular MR contrast media (gadolinium dendrimer) on 3D time of flight magnetic resonance angiography of the body [J].
Bourne, MW ;
Margerun, L ;
Hylton, N ;
Campion, B ;
Lai, JJ ;
Derugin, N ;
Higgins, CB .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (02) :305-310
[6]   CONTRAST-ENHANCED NMR IMAGING - ANIMAL STUDIES USING GADOLINIUM-DTPA COMPLEX [J].
BRASCH, RC ;
WEINMANN, HJ ;
WESBEY, GE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 142 (03) :625-630
[7]  
COROT C, 1999, IN PRESS J MAGN RESO
[8]   GADOLINIUM-ENHANCED MR ANGIOGRAPHY [J].
CREASY, JL ;
PRICE, RR ;
PRESBREY, T ;
GOINS, D ;
PARTAIN, CL ;
KESSLER, RM .
RADIOLOGY, 1990, 175 (01) :280-283
[9]   Magnetic resonance angiography with gadomer-17 - An animal study original investigation [J].
Dong, Q ;
Hurst, DR ;
Weinmann, HJ ;
Chenevert, TL ;
Londy, FJ ;
Prince, MR .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :699-708
[10]   FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE [J].
DOUEK, PC ;
REVEL, D ;
CHAZEL, S ;
FALISE, B ;
VILLARD, J ;
AMIEL, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :431-437