Fully automatic luminal contour segmentation in intracoronary ultrasound imaging - A statistical approach

被引:101
作者
Brusseau, E [1 ]
de Korte, CL
Mastik, F
Schaar, J
van der Steen, AFW
机构
[1] INSERM U630, CREATIS UMR CNRS 5515, Lyon, France
[2] Erasmus Univ, Med Ctr, Ctr Thorax, NL-3015 GD Rotterdam, Netherlands
[3] Interuniv Cardiol Inst Netherlands, NL-3501 DG Utrecht, Netherlands
关键词
active contour; coronary artery; echo envelope statistics; intravascular ultrasound; Rayleigh distribution; segmentation; snakes;
D O I
10.1109/TMI.2004.825602
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
In this paper, a fully automatic method for luminal contour segmentation in intracoronary ultrasound imaging is introduced. Its principle is based on a contour with a priori properties that evolves according to the statistics of the ultrasound texture brightness, which is generally Rayleigh distributed. The main interest of the technique is its fully automatic character. This is insured by an initial contour that is not set by the user, like in classical snake-based algorithms, but estimated and, thus, adapted to each image. Its estimation combines two pieces of information extracted from the a posteriori probability function of the contour position: the function maximum location (or maximum a posteriori estimator) and the first zero-crossing of its derivative. Then, starting from the initial contour, a region of interest is automatically selected and the process iterated until the contour evolution can be ignored. In vivo coronary images from 15 patients, acquired with the 20-MHz central frequency Joined Invision ultrasound scanner, were segmented with the developed method. Automatic contours were compared to those manually drawn by two physicians in terms of mean absolute difference. The results demonstrate that the error between automatic contours and the average of manual ones is of small amplitude, and only very slightly higher (0.099 +/- 0.032 mm) than the interexpert error (0.097 +/- 0.027 mm).
引用
收藏
页码:554 / 566
页数:13
相关论文
共 52 条
[1]
SEMIAUTOMATED BORDER TRACKING OF CINE ECHOCARDIOGRAPHIC VENTRICULAR IMAGES [J].
ADAM, D ;
HAREUVENI, O ;
SIDEMAN, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (03) :266-271
[2]
[Anonymous], 1994, P COMP CARD
[3]
[Anonymous], BIOL ENG
[4]
BAMBER JC, 1986, PHYS PRINCIPLES MED, P495
[5]
Axial strain imaging of intravascular data: Results on polyvinyl alcohol cryogel phantoms and carotid artery [J].
Brusseau, E ;
Fromageau, J ;
Finet, G ;
Delachartre, P ;
Vray, D .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (12) :1631-1642
[6]
Deformable boundary finding in medical images by integrating gradient and region information [J].
Chakraborty, A ;
Staib, LH ;
Duncan, JS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (06) :859-870
[7]
NON-GAUSSIAN VERSUS NON-RAYLEIGH STATISTICAL PROPERTIES OF ULTRASOUND ECHO SIGNALS [J].
CHEN, JF ;
ZAGZEBSKI, JA ;
MADSEN, EL .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (04) :435-440
[8]
Statistical region snake-based segmentation adapted to different physical noise models [J].
Chesnaud, C ;
Réfrégier, P ;
Boulet, V .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1999, 21 (11) :1145-1157
[9]
CHESNAUD C, 1999, PSIP 99, P3
[10]
ON ACTIVE CONTOUR MODELS AND BALLOONS [J].
COHEN, LD .
CVGIP-IMAGE UNDERSTANDING, 1991, 53 (02) :211-218