Electrospray ionization Fourier transform ion cyclotron resonance analysis of large polymerase chain reaction products

被引:17
作者
Wunschel, DS [1 ]
Tolic, LP [1 ]
Feng, BB [1 ]
Smith, RD [1 ]
机构
[1] Pacific NW Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1016/S1044-0305(99)00156-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In previous work, we demonstrated the use of electrospray ionization to analyze small differences in size or sequence of relatively small polymerase chain reaction (PCR) products of 114 base pairs or less. The sequence information required to answer a biological question may be only a single nucleotide substitution or deletion. In many cases, the regions where these sequence variations can occur are several hundred base pairs in length, and the analysis of large PCR products is therefore desirable. Therefore, we have attempted to expand the size range of PCR products that can be analyzed by electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometry. Previous work has shown that the difficulties associated with PCR product analysis increase with product size. A revised cleanup scheme was employed to target the removal of detergents with ethanol wash or precipitation steps, followed by additional desalting. Additionally, an in-trap cleanup to collisionally induce dissociation of noncovalent salt adducts was employed. This approach was extended to a 223 base pair PCR product yielding mass measurement accuracy within 26 ppM. The mass measurement accuracy obtained illustrates that a single base substitution could be identified at this size of PCR product with a 7 tesla ESI-FTICR. (J Am Soc Mass Spectrom 2000, 11, 33-337) (C) 2000 American Society for Mass Spectrometry.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 29 条
[1]  
ANDERSON GA, 1995, ICR2LS
[2]   Infrared MALDI mass spectrometry of large nucleic acids [J].
Berkenkamp, S ;
Kirpekar, F ;
Hillenkamp, F .
SCIENCE, 1998, 281 (5374) :260-262
[3]  
BRUCE JE, IN PRESS J AM SOC MA
[4]   Stable-isotope-assisted MALDI-TOF mass spectrometry for accurate determination of nucleotide compositions of PCR products [J].
Chen, X ;
Fei, ZD ;
Smith, LM ;
Bradbury, EM ;
Majidi, V .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3118-3125
[5]  
ERLICH HA, 1992, ANNU REV GENET, V26, P479, DOI 10.1146/annurev.ge.26.120192.002403
[6]   UTILITY OF ORGANIC-BASES FOR IMPROVED ELECTROSPRAY MASS-SPECTROMETRY OF OLIGONUCLEOTIDES [J].
GREIG, M ;
GRIFFEY, RH .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (01) :97-102
[7]  
Hurst GB, 1996, RAPID COMMUN MASS SP, V10, P377, DOI 10.1002/(SICI)1097-0231(199602)10:3<377::AID-RCM481>3.3.CO
[8]  
2-O
[9]   Recovery of nucleic acids from immobilized biotin-streptavidin complexes using ammonium hydroxide and applications in MALDI-TOF mass spectrometry [J].
Jurinke, C ;
vandenBoom, D ;
Collazo, V ;
Luchow, A ;
Jacob, A ;
Koster, H .
ANALYTICAL CHEMISTRY, 1997, 69 (05) :904-910
[10]   Infrared photodissociation of non-covalent adducts of electrosprayed nucleotide ions [J].
Little, DP ;
McLafferty, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (02) :209-210