Three-dimensional, time-resolved motion of the coronary arteries

被引:62
作者
Johnson, KR
Patel, SJ
Whigham, A
Hakim, A
Pettigrew, RI
Oshinski, JN
机构
[1] Emory Univ, Sch Med, Dept Radiol, Frederick Philips MR Res Lab, Atlanta, GA 30322 USA
[2] Emory Univ, Sch Med, Georgia Inst Technol, Dept Biomed Engn, Atlanta, GA 30322 USA
[3] Emory Univ, Sch Med, Dept Med Cardiol, Atlanta, GA 30322 USA
关键词
coronary artery motion; coronary artery disease; CT; MRI; coronary angiography;
D O I
10.1081/JCMR-120038086
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Coronary artery motion can decrease image quality during coronary magnetic resonance angiography and computed tomography coronary angiography. Purpose. To characterize the three-dimensional motion of the coronary arteries along the entire vessel length and to identify the temporal location and duration of periods of relatively low cardiac motion in patients with coronary artery disease. Methods. Archived digital, biplane x-ray angiography films acquired at 30 frames per second with simultaneous electrocardiogram recording were reviewed for 15 patients with coronary artery disease. The right coronary (RCA), left anterior descending (LAD), and left circumflex (LCX) arteries were divided into proximal, mid, and distal segments. The displacement and velocity of a point in each segment were calculated throughout the heart cycle. Time-dependent, three-dimensional motion of each segment on each vessel was determined. Periods of the heart cycle during which maximal displacement was less than 1 mm or 0.5 mm per frame for each artery were determined. Results. A period lasting an average of 187 msec was seen during mid-diastole (72 +/- 5% of the cardiac cycle) in which all three coronary arteries studied had relatively little motion. This period of quiescence was consistent along the length of the arteries. Although the amount of motion did vary along the length of the arteries, there was no difference in the timing of rest periods in the proximal, mid, and distal segments using a < 1 mm per frame threshold. The periods of low motion were significantly reduced in length and often altogether eliminated when the 0.5 mm per frame threshold was used.
引用
收藏
页码:663 / 673
页数:11
相关论文
共 34 条
[1]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[3]  
Borrello J A, 1997, Magn Reson Imaging Clin N Am, V5, P83
[4]   Physiological neuroimaging: emerging clinical applications [J].
Derdeyn, CP .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (24) :3065-3068
[5]   Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms [J].
Ding, ZH ;
Friedman, MH .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (05) :331-346
[6]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[7]   Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection [J].
Giesler, T ;
Baum, U ;
Ropers, D ;
Ulzheimer, S ;
Wenkel, E ;
Mennicke, M ;
Bautz, W ;
Kalender, WA ;
Daniel, WG ;
Achenbach, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) :911-916
[8]  
Grossman W., 1986, CARDIAC CATHETERIZAT, Vxiii, P562
[9]   Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification [J].
Hofman, MBM ;
Wickline, SA ;
Lorenz, CH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :568-576
[10]   Motion artifact reduction and vessel enhancement for free-breathing navigator-gated coronary MRA using 3D k-space reordering [J].
Huber, ME ;
Hengesbach, D ;
Botnar, RM ;
Kissinger, KV ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :645-652