Multiple-electrode radiofrequency ablation creates confluent areas of necrosis: In vivo porcine liver results

被引:67
作者
Laeseke, Paul F.
Sampson, Lisa A.
Haemmerich, Dieter
Brace, Christopher L.
Fine, Jason P.
Frey, Tina M.
Winter, Thomas C., III
Lee, Fred T., Jr.
机构
[1] Univ Wisconsin, Clin Sci Ctr E3, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Clin Sci Ctr E3, Dept Biostat & Med Informat, Madison, WI 53792 USA
[3] Med Univ S Carolina, Dept Pediat, Charleston, SC 29425 USA
关键词
D O I
10.1148/radiol.2411051271
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively evaluate, in vivo in pigs, an impedance-based multiple-electrode radiofrequency (RF) ablation system for creation of confluent areas of hepatic coagulation. Materials and Methods: The study was preapproved by the institutional research animal care and use committee. A prototype multiple-electrode RF system that enables switching between three electrically independent electrodes at impedance spikes was created. Forty-two coagulation zones (18 with single, 12 with cluster, and 12 with multiple [three single electrodes spaced 2 cm apart] electrodes) were created at laparotomy in 15 female pigs. Half the ablations were performed for 12 minutes, and half were performed for 16 minutes. The coagulation zones were excised and sliced into approximately 3-mm sections for measurement. Analysis of variance and two-sample t tests (with Bonferroni correction, alpha = .0033) were used to assess for differences between groups. Results: At 12 minutes, the mean multiple-electrode coagulation was significantly larger than the mean single-electrode coagulation (minimum diameter, 2.8 vs 1.6 cm; maximum diameter, 4.2 vs 2.0 cm; volume, 22.1 vs 6.7 cm(3); P < .0033 for all comparisons). The mean maximum diameter achieved at 12 minutes with multiple electrodes was significantly larger than that achieved with the cluster electrode (4.2 vs 2.9 cm, P = .02). At 16 minutes, the mean multiple-electrode coagulation (minimum diameter, 3.2 cm; maximum diameter, 4.2 cm; volume, 29.1 cm3) was significantly larger than the mean single-electrode (minimum diameter, 1.7 cm; maximum diameter, 2.2 cm; volume, 7.1 cm(3); P < .0033 for all comparisons) and cluster-electrode (minimum diameter: 2.3 cm, P = .007; maximum diameter: 3.2 cm, P = .005; volume: 13.1 cm(3), P = .001) coagulations. Conclusion: Compared with the single and cluster systems used as controls, the multiple-electrode RF ablation system enabled the creation of significantly larger coagulation zones.
引用
收藏
页码:116 / 124
页数:9
相关论文
共 35 条
[1]   Percutaneous radiofrequency ablation of lung neoplasms: Initial therapeutic response [J].
Akeboshi, M ;
Yamakado, K ;
Nakatsuka, A ;
Hataji, O ;
Taguchi, O ;
Takao, M ;
Takeda, K .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (05) :463-470
[2]  
[Anonymous], 2000, FUNDAMENTALS PHYS
[3]   Percutaneous radiofrequency ablation of liver tumors with the LeVeen probe: Is roll-off predictive of response? [J].
Arata, MA ;
Nisenbaum, HL ;
Clark, TWI ;
Soulen, MC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (04) :455-458
[4]   Laparoscopic radiofrequency ablation of hepatic tumors - Prospective clinical evaluation of ablation size comparing two treatment algorithms [J].
Berber, E ;
Herceg, NL ;
Casto, KJ ;
Siperstein, AE .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2004, 18 (03) :390-396
[5]   Surgical margin in hepatic resection for colorectal metastasis - A critical and improvable determinant of outcome [J].
Cady, B ;
Jenkins, RL ;
Steele, GD ;
Lewis, WD ;
Stone, MD ;
McDermott, WV ;
Jessup, JM ;
Bothe, A ;
Lalor, P ;
Lovett, EJ ;
Lavin, P ;
Linehan, DC .
ANNALS OF SURGERY, 1998, 227 (04) :566-571
[6]   CT versus sonography for monitoring radiofrequency ablation in a porcine liver [J].
Cha, CH ;
Lee, FT ;
Gurney, JM ;
Markhardt, BK ;
Warner, TF ;
Kelcz, F ;
Mahvi, DM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (03) :705-711
[7]   Effects of perfusion on radiofrequency ablation in Swine kidneys [J].
Chang, I ;
Mikityansky, I ;
Wray-Cahen, D ;
Pritchard, W ;
Karanian, JW ;
Wood, BJ .
RADIOLOGY, 2004, 231 (02) :500-505
[8]   Effect of vascular occlusion on radiofrequency ablation of the liver: Results in a porcine model [J].
Chinn, SB ;
Lee, FT ;
Kennedy, GD ;
Chinn, C ;
Johnson, CD ;
Winter, TC ;
Warner, TF ;
Mahvi, DM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (03) :789-795
[9]  
Do Carmo Manfredo P, 2016, Differential geometry of curves & surfaces, Vsecond
[10]   Radiofrequency thermal ablation: Computer analysis of the size of the thermal injury created by overlapping ablations [J].
Dodd, GD ;
Frank, MS ;
Aribandi, M ;
Chopra, S ;
Chintapalli, KN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (04) :777-782