Monte Carlo simulation of the Leksell Gamma Knife®:: I.: Source modelling and calculations in homogeneous media

被引:49
作者
Moskvin, V [1 ]
DesRosiers, C [1 ]
Papiez, L [1 ]
Timmerman, R [1 ]
Randall, M [1 ]
DesRosiers, P [1 ]
机构
[1] Indiana Univ, Sch Med, Dept Radiat Oncol, Indianapolis, IN 46202 USA
关键词
D O I
10.1088/0031-9155/47/12/301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Monte Carlo code PENELOPE has been used to simulate photon flux from the Leksell Gamma Knife((R)), a precision method for treating intracranial lesions. Radiation from a single Co-60 assembly traversing the collimator system was simulated, and phase space distributions at the output surface of the helmet for photons and electrons were calculated. The characteristics describing the emitted final beam were used to build a two-stage Monte Carlo simulation of irradiation of a target. A dose field inside a standard spherical polystyrene phantom, usually used for Gamma Knife((R)) dosimetry, has been computed and compared with experimental results, with calculations performed by other authors with the use of the EGS4 Monte Carlo code, and data provided by the treatment planning system Gamma Plan((R)). Good agreement was found between these data and results of simulations in homogeneous media. Owing to this established accuracy, PENELOPE is suitable for simulating problems relevant to stereotactic radiosurgery.
引用
收藏
页码:1995 / 2011
页数:17
相关论文
共 30 条
[1]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[2]  
[Anonymous], 1983, MED PHYS, V10, P741
[3]  
[Anonymous], 2000, LA13709M LOS AL NAT
[4]   PENELOPE - AN ALGORITHM FOR MONTE-CARLO SIMULATION OF THE PENETRATION AND ENERGY-LOSS OF ELECTRONS AND POSITRONS IN MATTER [J].
BARO, J ;
SEMPAU, J ;
FERNANDEZVAREA, JM ;
SALVAT, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 100 (01) :31-46
[5]  
BENJAMIN WC, 1997, SEMIN ONCOL, V24, P707
[6]  
Bielajew A., 1990, The Dosimetry of Ionizing Radiation, Volume, P427
[7]   Monte Carlo calculation of single-beam dose profiles used in a gamma knife treatment planning system [J].
Cheung, JYC ;
Yu, KN ;
Yu, CP ;
Ho, RTK .
MEDICAL PHYSICS, 1998, 25 (09) :1673-1675
[8]   Monte Carlo calculations and GafChromic film measurements for plugged collimator helmets of Leksell Gamma Knife unit [J].
Cheung, JYC ;
Yu, KN ;
Ho, RTK ;
Yu, CP .
MEDICAL PHYSICS, 1999, 26 (07) :1252-1256
[9]   Monte Carlo calculated output factors of a Leksell Gamma Knife unit [J].
Cheung, JYC ;
Yu, KN ;
Ho, RTK ;
Yu, CP .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12) :N247-N249
[10]   Dose distributions at extreme irradiation depths of gamma knife radiosurgery: EGS4 Monte Carlo calculations [J].
Cheung, JYC ;
Yu, KN ;
Yu, CP ;
Ho, RTK .
APPLIED RADIATION AND ISOTOPES, 2001, 54 (03) :461-465