Precise temperature control and rapid thermal cycling in a micromachined DNA polymerase chain reaction chip

被引:119
作者
Yoon, DS
Lee, YS
Lee, Y
Cho, HJ
Sung, SW
Oh, KW
Cha, J
Lim, G
机构
[1] Samsung Adv Inst Technol, Biochip Project Team, Suwon, South Korea
[2] Samsung Adv Inst Technol, MEMS Lab, Suwon, South Korea
[3] Samsung Adv Inst Technol, Computat Sci & Engn Ctr, Suwon, South Korea
[4] Samsung Adv Inst Technol, MEMS Lab, Suwon, South Korea
[5] Korea Adv Inst Sci & Technol, Dept Chem & Biomol Engn, Yuseong Gu, Taejon 305701, South Korea
[6] Korea Adv Inst Sci & Technol, Ctr Ultramicrochem Proc Syst, Yuseong Gu, Taejon 305701, South Korea
关键词
D O I
10.1088/0960-1317/12/6/312
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have fabricated Si-based micromachined DNA polymerase chain reaction (PCR) chips with different groove depths. The platinum thin-film micro heater and the temperature sensor have been integrated on the chip. The volume of the PCR chamber in the chip is about 3.6 mul and the chip size is 17 x 40 mm(2). The effects of groove geometry, including width, depth and position, on the thermal characteristics of the PCR chip have been investigated by numerical analysis and experimental measurement. From the results, the power consumption required for the PCR chip is reduced with the increase of groove depth. Compared with results for the case of no groove, the power consumption of the chip with a groove of 280 mum is reduced by 24.0%, 23.3% and 25.6% with annealing, extension and denaturation, respectively. The heating rate is increased rapidly with the increase of the groove depth. In particular, it is revealed that this effect is predominant for depths in the region above 280 mum. For a more precise control of chip temperature, the nonlinear feedback proportional-integral control scheme is used. The obtained heating and cooling rates are about 36 degreesC s(-1) and 22 degreesC s(-1), respectively. The overshoot and the steady state error are less than 0.7 degreesC and +/-0.1 degreesC, respectively. In the experiment, the effects of the PCR buffer and the bubbles in the chamber on the temperature uniformity have also been studied. From the temperature measurement, it is revealed that the temperature difference between the thin-film sensor (on the lower plate) and the PCR buffer can be neglected if there is no air bubble in the PCR buffer. With such a high performance control scheme, we could implement a remarkable thermal cycling of conducting 30 cycles for 3 min. Finally, the chip PCR of plasmid DNA was successfully performed with no additives using the temperature control system.
引用
收藏
页码:813 / 823
页数:11
相关论文
共 25 条
[1]  
[Anonymous], 1994, POLYMERASE CHAIN REA
[2]   Chip PCR .2. Investigation of different PCR amplification systems in microfabricated silicon-glass chips [J].
Cheng, J ;
Shoffner, MA ;
Hvichia, GE ;
Kricka, LJ ;
Wilding, P .
NUCLEIC ACIDS RESEARCH, 1996, 24 (02) :380-385
[3]   A miniaturized cyclic PCR device - modeling and experiments [J].
Chou, CF ;
Changrani, R ;
Roberts, P ;
Sadler, D ;
Burdon, J ;
Zenhausern, F ;
Lin, S ;
Mulholland, A ;
Swami, N ;
Terbrueggen, R .
MICROELECTRONIC ENGINEERING, 2002, 61-2 :921-925
[4]   Silicon microchambers for DNA amplification [J].
Daniel, JH ;
Iqbal, S ;
Millington, RB ;
Moore, DF ;
Lowe, CR ;
Leslie, DL ;
Lee, MA ;
Pearce, MJ .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 71 (1-2) :81-88
[5]  
EELES R. A., 1993, POLYMERASE CHAIN REA
[6]   Polymerase chain reaction in polymeric microchips:: DNA amplification in less than 240 seconds [J].
Giordano, BC ;
Ferrance, J ;
Swedberg, S ;
Hühmer, AFR ;
Landers, JP .
ANALYTICAL BIOCHEMISTRY, 2001, 291 (01) :124-132
[7]   Integrated system for rapid PCR-based DNA analysis in microfluidic devices [J].
Khandurina, J ;
McKnight, TE ;
Jacobson, SC ;
Waters, LC ;
Foote, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2995-3000
[8]   Chemical amplification: Continuous-flow PCR on a chip [J].
Kopp, MU ;
de Mello, AJ ;
Manz, A .
SCIENCE, 1998, 280 (5366) :1046-1048
[9]   Single-molecule DNA amplification and analysis in an integrated microfluidic device [J].
Lagally, ET ;
Medintz, I ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :565-570
[10]   Precise temperature control of microfluidic chamber for gas and liquid phase reactions [J].
Lao, AIK ;
Lee, TMH ;
Hsing, IM ;
Ip, NY .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 84 (1-2) :11-17