Two-year follow-up on joint stability and muscular function comparing rotating versus fixed bearing TKR

被引:27
作者
Luring, C. [1 ]
Bathis, H. [1 ]
Oczipka, F. [1 ]
Trepte, C. [1 ]
Lufen, H. [1 ]
Perlick, L. [1 ]
Grifka, J. [1 ]
机构
[1] Univ Regensburg, Dept Orthopaed Surg, D-93077 Bad Abbach, Germany
关键词
total knee arthroplasty; mobile bearing; fixed bearing; computer-assisted surgery; joint stability;
D O I
10.1007/s00167-005-0020-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Mobile and fixed bearing in total knee replacement are still discussed controversially. In a retrospective, matched-pair study, we investigated 40 patients with computer-assisted (BrainLAB (R)) primary total knee replacement (PFC Sigma (R), DePuy (R)) performed two years before. Twenty patients each received a mobile bearing and a fixed bearing. We compared Womac Score, Knee Society Score, postoperative ROM, fluoroscopic measurement of knee stability in flexion and extension and isokinetic muscle strength using a Biodex (TM)-3 dynamometer. Both groups showed similar results concerning WOMAC Score (total rotating bearing: 23.05; fixed bearing: 22.57), KSS (rotating bearing: 174.89; fixed bearing: 176.1). Isokinetic muscle force demonstrated statistically significant superior results for knee flexion in the rotating bearing group. Medio-lateral stability revealed statistically significant superior results for the rotating bearing compared to fixed bearing in extension (P > 0.05). In flexion only lateral stability was superior (P > 0.05). Two-year clinical follow-up after computer-assisted total knee replacement resulted in good clinical outcome with high patient satisfaction. Statistically significant better values for the rotating platform group were found for the medio-lateral stability in extension and the peak flexion torque.
引用
收藏
页码:605 / 611
页数:7
相关论文
共 35 条
[1]
[Anonymous], 2004, COCHRANE DB SYST REV, DOI DOI 10.1002/14651858.CD003130.PUB2
[2]
CT-based and CT-free navigation in total knee arthroplasty.: Results of a prospective study [J].
Bäthis, H ;
Perlick, L ;
Lüring, C ;
Kalteis, T ;
Grifka, J .
UNFALLCHIRURG, 2003, 106 (11) :935-940
[3]
Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[4]
Bellamy N, 1997, J RHEUMATOL, V24, P2413
[5]
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[6]
BUECHEL FF, 1990, CLIN ORTHOP RELAT R, P162
[7]
BUECHEL FF, 2001, CLIN ORTHOP RELAT R, V388, P41
[8]
Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study [J].
Callaghan, JJ ;
Squire, MW ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :705-711
[9]
Chen FS, 1999, J BIOMED MATER RES, V48, P904, DOI 10.1002/(SICI)1097-4636(1999)48:6<904::AID-JBM21>3.0.CO
[10]
2-5