Development and validation of a liquid chromatography-mass spectrometry assay for polymyxin B in bacterial growth media

被引:39
作者
Cheah, Soon-Ee [1 ]
Bulitta, Jurgen B. [1 ]
Li, Jian [1 ]
Nation, Roger L. [1 ]
机构
[1] Monash Univ, Monash Inst Pharmaceut Sci, Parkville, Vic 3052, Australia
基金
美国国家卫生研究院;
关键词
Polymyxin B; Liquid chromatography-mass spectrometry; Mueller-Hinton broth; Tryptone soya broth; Colistin; CRITICALLY-ILL PATIENTS; HUMAN PLASMA; COLISTIN METHANESULFONATE; PHARMACOKINETICS; PHASE; COMPONENTS; URINE;
D O I
10.1016/j.jpba.2014.01.015
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
There is increasing interest in the optimization of polymyxin B dosing regimens to treat infections caused by multidrug-resistant Gram-negative bacteria. We aimed to develop and validate a liquid chromatography-single quadrupole mass spectrometry (LC-MS) method to quantify polymyxin B in two growth media commonly used in in vitro pharmacodynamic studies, cation-adjusted Mueller-Hinton and tryptone soya broth. Samples were pre-treated with sodium hydroxide (1.0 M) and formic acid in acetonitrile (1:100, v/v) before analysis. The summed peak areas of polymyxin B1 and B2 relative to the summed peak areas of colistin A and B (internal standard) were used to quantify polymyxin B. Quality control samples were prepared and analyzed to assess the intra- and inter-day accuracy and precision. The robustness of the assay in the presence of bacteria and commonly co-administered antibiotics (rifampicin, doripenem, imipenem, cefepime and tigecycline) was also examined. Chromatographic separation was achieved with retention times of approximately 9.7 min for polymyxin B2 and 10.4 min for polymyxin B1. Calibration curves were linear between 0.103 and 6.60 mg/L. Accuracy (% relative error) and precision (% coefficient of variation), pooled for all assay days and matrices (n = 84), were -6.85% (8.17%) at 0.248 mg/L, 1.73% (6.15%) at 2.48 mg/L and 1.54% (5.49%) at 4.95 mg/L, and within acceptable ranges at all concentrations examined. Further, the presence of high bacterial concentrations or of commonly co-administered antibiotics in the samples did not affect the assay. The accuracy, precision and cost-efficiency of the assay make it ideally suited to quantifying polymyxin B in samples from in vitro pharmacodynamic models. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 17 条
[1]
Bad Bugs, No Drugs: No ESKAPE! An Update from the Infectious Diseases Society of America [J].
Boucher, Helen W. ;
Talbot, George H. ;
Bradley, John S. ;
Edwards, John E., Jr. ;
Gilbert, David ;
Rice, Louis B. ;
Scheld, Michael ;
Spellberg, Brad ;
Bartlett, John .
CLINICAL INFECTIOUS DISEASES, 2009, 48 (01) :1-12
[2]
Development and validation of a reversed-phase high-performance liquid chromatography assay for polymyxin B in human plasma [J].
Cao, Guoying ;
Ali, Feda' Emad Atta ;
Chiu, Francis ;
Zavascki, Alexandre P. ;
Nation, Roger L. ;
Li, Jian .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2008, 62 (05) :1009-1014
[3]
LC-MS/MS method development and validation for the determination of polymyxins and vancomycin in rat plasma [J].
Cheng, Chang ;
Liu, Shaorong ;
Xiao, Deqing ;
Hollembaek, John ;
Yao, Lili ;
Lin, Jing ;
Hansel, Steven .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (28) :2831-2838
[4]
Validation of a novel LC-MS/MS method for the quantitation of colistin A and B in human plasma [J].
Dotsikas, Yannis ;
Markopoulou, Catherine K. ;
Koundourellis, John E. ;
Loukas, Yannis L. .
JOURNAL OF SEPARATION SCIENCE, 2011, 34 (01) :37-45
[5]
Determination of colistin A and colistin B in human plasma by UPLC-ESI high resolution tandem MS: Application to a pharmacokinetic study [J].
Gikas, Evangelos ;
Bazoti, Fotini N. ;
Katsimardou, Marina ;
Anagnostopoulos, Dimitrios ;
Papanikolaou, Konstantinos ;
Inglezos, Ilias ;
Skoutelis, Athanasios ;
Daikos, Georgios L. ;
Tsarbopoulos, Anthony .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 83 :228-236
[6]
Assay of Colistin and Colistin Methanesulfonate in Plasma and Urine by Liquid Chromatography-Tandem Mass Spectrometry [J].
Gobin, Patrice ;
Lemaitre, Florian ;
Marchand, Sandrine ;
Couet, William ;
Olivier, Jean-Christophe .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2010, 54 (05) :1941-1948
[7]
Variability of polymyxin B major components in commercial formulations [J].
He, Jie ;
Ledesma, Kimberly R. ;
Lam, Wai-Ying ;
Figueroa, Deborah A. ;
Lim, Tze-Peng ;
Chow, Diana S. -L. ;
Tam, Vincent H. .
INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2010, 35 (03) :308-310
[8]
Quantitative analysis of colistin A and colistin B in plasma and culture medium using a simple precipitation step followed by LC/MS/MS [J].
Jansson, Britt ;
Karvanen, Matti ;
Cars, Otto ;
Plachouras, Diamantis ;
Friberg, Lena E. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) :760-767
[9]
Karvanen M, 2011, 51 INT C ANT AG CHEM
[10]
Pharmacokinetics of polymyxin B1 in patients with multidrug-resistant Gram-negative bacterial infections [J].
Kwa, Andrea L. H. ;
Lim, Tze-Peng ;
Low, Jenny G. H. ;
Hou, JingGuo ;
Kurup, Asok ;
Prince, Randall A. ;
Tam, Vincent H. .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2008, 60 (02) :163-167