Slice location dependence of aortic regurgitation measurements with MR phase velocity mapping

被引:50
作者
Chatzimavroudis, GP
Walker, PG
Oshinski, JN
Franch, RH
Pettigrew, RI
Yoganathan, AP
机构
[1] GEORGIA INST TECHNOL,SCH CHEM ENGN,INST BIOENGN & BIOSCI,CARDIOVASC FLUID MECH LAB,ATLANTA,GA 30332
[2] UNIV LEEDS,DEPT MECH ENGN,LEEDS LS2 9JT,W YORKSHIRE,ENGLAND
[3] EMORY UNIV HOSP,DEPT RADIOL,FREDERIK PHILIPS MAGNET RESONANCE RES CTR,ATLANTA,GA 30322
[4] EMORY UNIV HOSP,DEPT CARDIOL,ATLANTA,GA 30322
关键词
aortic regurgitation; regurgitant volume; magnetic resonance phase velocity mapping; aortic compliance; QUANTITATIVE FLOW MEASUREMENTS; VALVULAR REGURGITATION; MITRAL REGURGITATION; DOPPLER; SEVERITY; QUANTIFICATION; INSUFFICIENCY; ACCELERATION; ACCURACY; ORIFICE;
D O I
10.1002/mrm.1910370412
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although several methods have been used clinically to assess aortic regurgitation (AR), there is no ''gold standard'' for regurgitant volume measurement, Magnetic resonance phase velocity mapping (PVM) can be used for noninvasive blood flow measurements, To evaluate the accuracy of PVM in quantifying AR with a single imaging slice in the ascending aorta, in vitro experiments were performed by using a compliant aortic model, Attention was focused on determining the slice location that provided the best results, The most accurate measurements were taken between the aortic valve annulus and the coronary ostia where the measured (Y) and actual (X) flow rate had close agreement (Y = 0.954 x + 0.126, r(2) = 0.995, standard deviation of error = 0.139 L/min), Beyond the coronary ostia, coronary flow and aortic compliance negatively affected the accuracy of the measurements, In vivo measurements taken on patients with AR showed the same tendency with the in vitro results, In making decisions regarding patient treatment, diagnostic accuracy is very important, The results from this study suggest that higher accuracy is achieved by placing the slice between the aortic valve and the coronary ostia and that this is the region where attention should be focused for further clinical investigation.
引用
收藏
页码:545 / 551
页数:7
相关论文
共 31 条
[1]   ESTIMATION OF REGURGITANT VOLUME AND ORIFICE IN AORTIC REGURGITATION COMBINING CW DOPPLER AND PARAMETER-ESTIMATION IN A WINDKESSEL-LIKE MODEL [J].
ANGELSEN, BAJ ;
SLORDAHL, SA ;
SOLBAKKEN, JE ;
SAMSTAD, SO ;
LINKER, DT ;
TORP, H ;
PIENE, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (10) :930-936
[2]  
Cape E G, 1995, J Am Soc Echocardiogr, V8, P585, DOI 10.1016/S0894-7317(05)80371-2
[3]   CYSTIC MEDIAL NECROSIS OF ASCENDING AORTA IN RELATION TO AGE AND HYPERTENSION [J].
CARLSON, RG ;
LILLEHEI, WC ;
EDWARDS, JE .
AMERICAN JOURNAL OF CARDIOLOGY, 1970, 25 (04) :411-&
[4]   PULSED DOPPLER ECHOCARDIOGRAPHY IN THE DIAGNOSIS AND ESTIMATION OF SEVERITY OF AORTIC-INSUFFICIENCY [J].
CIOBANU, M ;
ABBASI, AS ;
ALLEN, M ;
HERMER, A ;
SPELLBERG, R .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (02) :339-343
[5]  
Cranney G B, 1990, Curr Probl Cardiol, V15, P87, DOI 10.1016/0146-2806(90)90028-O
[6]   LIMITATIONS OF QUALITATIVE ANGIOGRAPHIC GRADING IN AORTIC OR MITRAL REGURGITATION [J].
CROFT, CH ;
LIPSCOMB, K ;
MATHIS, K ;
FIRTH, BG ;
NICOD, P ;
TILTON, G ;
WINNIFORD, MD ;
HILLIS, LD .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (11) :1593-1598
[7]  
Dulce MC, 1992, RADIOLOGY, V185, P234
[8]   INVIVO VALIDATION OF MR VELOCITY IMAGING [J].
FIRMIN, DN ;
NAYLER, GL ;
KLIPSTEIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :751-756
[9]   QUANTITATIVE ASSESSMENT OF AORTIC REGURGITATION BY MAGNETIC-RESONANCE-IMAGING [J].
GLOBITS, S ;
FRANK, H ;
MAYR, H ;
NEUHOLD, A ;
GLOGAR, D .
EUROPEAN HEART JOURNAL, 1992, 13 (01) :78-83
[10]   Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurement: Effects of cardiac and respiratory motion [J].
Hofman, MBM ;
vanRossum, AC ;
Sprenger, M ;
Westerhof, N .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (04) :521-531