Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media

被引:291
作者
Grant, Katharine L. [1 ]
Flohr, Thomas G. [2 ,3 ]
Krauss, Bernhard [2 ]
Sedlmair, Martin [2 ]
Thomas, Christoph [3 ]
Schmidt, Bernhard [2 ,4 ]
机构
[1] Siemens Med Solut, Healthcare Sect, Computed Tomog Imaging & Therapy Div, Malvern, PA USA
[2] Siemens AG, Computed Tomog Imaging & Therapy Div, Healthcare Sect, D-91301 Forchheim, Germany
[3] Univ Tubingen, Inst Diagnost Radiol, Tubingen, Germany
[4] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
dual-energy CT; radiation dose; CT image quality; virtual monoenergetic CT; contrast-enhanced CT; PULMONARY CT ANGIOGRAPHY; VASCULAR ENHANCEMENT; RADIATION; ML; DIFFERENTIATION; OPTIMIZATION; PERFUSION; QUALITY; PHANTOM;
D O I
10.1097/RLI.0000000000000060
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Introduction: Following the trend of low-radiation dose computed tomographic (CT) imaging, concerns regarding the detectability of low-contrast lesions have been growing. The goal of this research was to evaluate whether a new image-based algorithm (Mono+) for virtual monoenergetic imaging with a dual-energy CT scanner can improve the contrast-to-noise ratio (CNR) and conspicuity of these low-contrast objects when using iodinated contrast media. Materials and Methods: Four circular phantoms of different diameter (10-40 cm) with an iodine insert at the center were scanned at a fixed radiation dose with different single-(80, 100, 120 kV) and dual-energy protocols (80/140 kV, 80/140 Sn kV, 100/140 Sn kV) using a dual-source CT system. In addition, an anthropomorphic abdominal phantom with different low-contrast lesions was scanned with the settings previously mentioned but also at only a half and a quarter of the initial dose. Dual-energy data were processed, and virtual monoenergetic images (range, 40-190 keV) were generated. Beside the established technique, a newly developed prototype algorithm to calculate monoenergetic images (Mono+) was used. To avoid noise increase at lower calculated energies, which is a known drawback of virtual monoenergetic images at low kilo electron-volt, a regional spatial frequency-based recombination of the high signal at lower energies and the superior noise properties at medium energies is performed to optimize CNR in case of Mono+ images. The CNR and low-contrast detectability were evaluated. Results: For all phantom sizes, the Mono+ technique provided increasing iodine CNR with decreasing kilo electron-volt, with the optimum CNR obtained at the lowest energy level of 40 keV. For all investigated phantom sizes, CNR of Mono+ images at low kilo electron-volt was superior to the CNR in single-energy images at an equivalent radiation dose and even higher than the CNR obtained with 80-kV protocols. In case of the anthropomorphic phantom, low-contrast detectability in monoenergetic images was, for all settings, similar to the circular phantoms, best for the voltage combination 80/140 Sn kV, irrespective of the dose level. For all dual-energy voltage combinations, the Mono+ algorithm led to superior results compared with single-energy imaging. Discussion: With regard to optimized iodine CNR, it is more efficient to perform dual-energy scans and compute virtual monoenergetic images at 40 keV using the Mono+ technique than to perform low kilovolt scans. Given the improved CNR, the Mono+ algorithm could be very useful in improving both detection and differential diagnosis of abdominal lesions, specifically low-contrast lesions, as well as in other anatomical regions where improved iodine CNR is beneficial.
引用
收藏
页码:586 / 592
页数:7
相关论文
共 25 条
[1]
[Anonymous], 2009, National Council on Radiation Protection and Measurement report No. 160: Ionizing radiation exposure of the population of the United States
[2]
Nephrotoxic effects in high-risk patients undergoing angiography. [J].
Aspelin, P ;
Aubry, P ;
Fransson, S ;
Strasser, R ;
Willenbrock, R ;
Berg, KJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (06) :491-499
[3]
Contrast-to-Noise Ratio and Low-Contrast Object Resolution on Full- and Low-Dose MDCT: SAFIRE Versus Filtered Back Projection in a Low-Contrast Object Phantom and in the Liver [J].
Baker, Mark E. ;
Dong, Frank ;
Primak, Andrew ;
Obuchowski, Nancy A. ;
Einstein, David ;
Gandhi, Namita ;
Herts, Brian R. ;
Purysko, Andrei ;
Remer, Erick ;
Vachani, Neil .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (01) :8-18
[4]
Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]
Which should be the routine cross-sectional reconstruction mode in spectral CT imaging: monochromatic or polychromatic? [J].
Cui, Y. ;
Gao, S-Y ;
Wang, Z-L ;
Li, X-T ;
Sun, Y-S ;
Tang, L. ;
Zhang, X-P .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018) :E887-E890
[6]
Spectral Optimization of Chest CT Angiography with Reduced Iodine Load: Experience in 80 Patients Evaluated with Dual-Source, Dual-Energy CT [J].
Delesalle, Marie-Aurelie ;
Pontana, Francois ;
Duhamel, Alain ;
Faivre, Jean-Baptiste ;
Flohr, Thomas ;
Tacelli, Nunzia ;
Remy, Jacques ;
Remy-Jardin, Martine .
RADIOLOGY, 2013, 267 (01) :256-266
[7]
80-kV Pulmonary CT Angiography With 40 mL of Iodinated Contrast Material in Lean Patients: Comparison of Vascular Enhancement With Iodixanol (320 mg I/mL) and Iomeprol (400 mg I/mL) [J].
Faggioni, Lorenzo ;
Neri, Emanuele ;
Sbragia, Paola ;
Pascale, Rachele ;
D'Errico, Luigia ;
Caramella, Davide ;
Bartolozzi, Carlo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) :1220-1225
[8]
Angiographic Reconstructions From Whole-Brain Perfusion CT for the Detection of Large Vessel Occlusion in Acute Stroke [J].
Froelich, Andreas M. J. ;
Psychogios, Marios N. ;
Klotz, Ernst ;
Schramm, Ramona ;
Knauth, Michael ;
Schramm, Peter .
STROKE, 2012, 43 (01) :97-102
[9]
Individualization of Abdominopelvic CT Protocols With Lower Tube Voltage to Reduce IV Contrast Dose or Radiation Dose [J].
Hough, David M. ;
Yu, Lifeng ;
Shiung, Maria M. ;
Carter, Rickey E. ;
Geske, Jennifer R. ;
Leng, Shuai ;
Fidler, Jeff L. ;
Huprich, James E. ;
Jondal, D. Y. ;
McCollough, Cynthia H. ;
Fletcher, Joel G. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (01) :147-153
[10]
Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517