Individualization of Abdominopelvic CT Protocols With Lower Tube Voltage to Reduce IV Contrast Dose or Radiation Dose

被引:23
作者
Hough, David M. [1 ]
Yu, Lifeng [1 ]
Shiung, Maria M. [1 ]
Carter, Rickey E. [1 ]
Geske, Jennifer R. [1 ]
Leng, Shuai [1 ]
Fidler, Jeff L. [1 ]
Huprich, James E. [1 ]
Jondal, D. Y. [1 ]
McCollough, Cynthia H. [1 ]
Fletcher, Joel G. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
关键词
contrast media; CT; low voltage; lymphoma; radiation dose; tube potential; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; ABDOMINAL CT; DYNAMIC CT; SELECTION; ENHANCEMENT; ANGIOGRAPHY; TUMORS; PHASE; NOISE;
D O I
10.2214/AJR.12.9295
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The purpose of this study was to validate an individualized approach to contrast-enhanced body CT using size-specific tube potential selection to reduce either IV contrast or radiation dose while maintaining diagnostic image quality. MATERIALS AND METHODS. With a validated noise insertion method and retrospective image quality assessment (scale 1-5, >= 3 acceptable), the lowest acceptable iodine contrast-to-noise ratio (CNR) was determined for 25 body CT examinations. Age-appropriate CT protocols with size-specific tube potential selection were then developed to accomplish two goals: IV contrast dose reduction for patients 50 years old and older and radiation dose reduction for patients younger than 50 years. After implementation, subjective and objective image quality metrics were retrospectively compared between the individualized scans and previous fixed-tube-potential scans. RESULTS. Diagnostically acceptable iodine CNR was achieved with use of up to 40% dose reduction from the baseline protocol. At this dose level, results of logistic regression analysis predicted 94% probability of acceptable image quality. With the individualized protocols that targeted this iodine CNR, 84 patients 50 years old and older had a mean IV contrast dose reduction of 26% (100.9 +/- 20.7 mL vs 136.2 +/- 24.9 mL; p < 0.001) with unchanged image quality scores (4.6 +/- 0.5 vs 4.6 +/- 0.4; p = 0.160). Thirty patients younger than 50 years had a mean radiation dose reduction of 41% (mean volume CT dose index, 11.6 +/- 5.3 mGy vs 19.7 +/- 7.8 mGy; p < 0.001) with acceptable but slightly reduced mean image quality scores (4.1 +/- 0.4 vs 4.7 +/- 0.4; p < 0.001). CONCLUSION. With the use of age-appropriate scan protocols and size-specific selection of tube potential, acceptable image quality can be maintained while IV contrast dose or radiation dose is substantially lowered.
引用
收藏
页码:147 / 153
页数:7
相关论文
共 15 条
[1]
Scan and contrast administration principles of MDCT [J].
Bae, KT ;
Heiken, JP .
EUROPEAN RADIOLOGY, 2005, 15 :E46-E59
[2]
Low-dose triple-rule-out using 320-row-detector volume MDCT - less contrast medium and lower radiation exposure [J].
Durmus, Tahir ;
Rogalla, Patrik ;
Lembcke, Alexander ;
Muehler, Matthias R. ;
Hamm, Bernd ;
Hein, Patrick A. .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1416-1423
[3]
Dual-energy MDCT: Comparison of pulmonary artery enhancement on dedicated CT pulmonary angiography, routine and low contrast volume studies [J].
Godoy, Myrna C. B. ;
Heller, Samantha L. ;
Naidich, David P. ;
Assadourian, Bernard ;
Leidecker, Christianne ;
Schmidt, Bernhard ;
Vlahos, Ioannis .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) :E11-E17
[4]
Appropriate Patient Selection at Abdominal Dual-Energy CT Using 80 kV: Relationship between Patient Size, Image Noise, and Image Quality [J].
Guimaraes, Luis S. ;
Fletcher, Joel G. ;
Harmsen, William S. ;
Yu, Lifeng ;
Siddiki, Hassan ;
Melton, Zachary ;
Huprich, James E. ;
Hough, David ;
Hartman, Robert ;
McCollough, Cynthia H. .
RADIOLOGY, 2010, 257 (03) :732-742
[5]
Lowering Kilovoltage to Reduce Radiation Dose in Contrast-Enhanced Abdominal CT: Initial Assessment of a Prototype Automated Kilovoltage Selection Tool [J].
Hough, David M. ;
Fletcher, Joel G. ;
Grant, Katharine L. ;
Fidler, Jeff L. ;
Yu, Lifeng ;
Geske, Jennifer R. ;
Carter, Rickey E. ;
Raupach, Rainer ;
Schmidt, Bernhard ;
Flohr, Thomas ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :1070-1077
[6]
Detection of Pancreatic Tumors, Image Quality, and Radiation Dose during the Pancreatic Parenchymal Phase: Effect of a Low-Tube-Voltage, High-Tube-Current CT Technique-Preliminary Results [J].
Marin, Daniele ;
Nelson, Rendon C. ;
Barnhart, Huiman ;
Schindera, Sebastian T. ;
Ho, Lisa M. ;
Jaffe, Tracy A. ;
Yoshizumi, Terry T. ;
Youngblood, Richard ;
Samei, Ehsan .
RADIOLOGY, 2010, 256 (02) :450-459
[7]
Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multidetector CT during Late Hepatic Arterial Phase for Detection-Initial Clinical Experience [J].
Marin, Daniele ;
Nelson, Rendon C. ;
Samei, Ehsan ;
Paulson, Erik K. ;
Ho, Lisa M. ;
Boll, Daniel T. ;
DeLong, David M. ;
Yoshizumi, Terry T. ;
Schindera, Sebastian T. .
RADIOLOGY, 2009, 251 (03) :771-779
[8]
Abdominal Dynamic CT in Patients with Renal Dysfunction: Contrast Agent Dose Reduction with Low Tube Voltage and High Tube Current-Time Product Settings at 256-Detector Row CT [J].
Nakaura, Takeshi ;
Awai, Kazuo ;
Maruyama, Natsuki ;
Takata, Noboru ;
Yoshinaka, Ichiro ;
Harada, Kazunori ;
Uemura, Shouzaburou ;
Yamashita, Yasuyuki .
RADIOLOGY, 2011, 261 (02) :467-476
[9]
Abdominal CT with low tube voltage: Preliminary observations about radiation dose, contrast enhancement, image quality, and noise [J].
Nakayama, Y ;
Awai, K ;
Funama, Y ;
Hatemura, M ;
Imuta, M ;
Nakaura, T ;
Ryu, D ;
Morishita, S ;
Sultana, S ;
Sato, N ;
Yamashita, Y .
RADIOLOGY, 2005, 237 (03) :945-951
[10]
Indirect Computed Tomography Venography With a Low-Tube-Voltage Technique: Reduction in the Radiation and Contrast Material Dose-A Prospective Randomized Study [J].
Oda, Seitaro ;
Utsunomiya, Daisuke ;
Awai, Kazuo ;
Takaoka, Hiroko ;
Nakaura, Takeshi ;
Katahira, Kazuhiro ;
Morishita, Syoji ;
Namimoto, Tomohiro ;
Yamashita, Yasuyuki .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (05) :631-636