Appropriate Patient Selection at Abdominal Dual-Energy CT Using 80 kV: Relationship between Patient Size, Image Noise, and Image Quality

被引:130
作者
Guimaraes, Luis S. [1 ]
Fletcher, Joel G. [1 ]
Harmsen, William S. [1 ]
Yu, Lifeng [1 ]
Siddiki, Hassan [1 ]
Melton, Zachary [1 ]
Huprich, James E. [1 ]
Hough, David [1 ]
Hartman, Robert [1 ]
McCollough, Cynthia H. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
关键词
LOW-TUBE VOLTAGE; COMPUTED-TOMOGRAPHY EXAMINATIONS; RAY TECHNIQUE FACTORS; BODY-SURFACE AREA; DOSE REDUCTION; PHANTOM; DIFFERENTIATION; FEASIBILITY; ABDOMEN;
D O I
10.1148/radiol.10092016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To determine the computed tomographic (CT) detector configuration, patient size, and image noise limitations that will result in acceptable image quality of 80-kV images obtained at abdominal dual-energy CT. Materials and Methods: The Institutional Review Board approved this HIPAA-compliant retrospective study from archival material from patients consenting to the use of medical records for research purposes. A retrospective review of contrast material-enhanced abdominal dual-energy CT scans in 116 consecutive patients was performed. Three gastrointestinal radiologists noted detector configuration and graded image quality and artifacts at specified levels-midliver, midpancreas, midkidneys, and terminal ileum-by using two five-point scales. In addition, an organ-specific enhancement-to-noise ratio and background noise were measured in each patient. Patient size was measured by using the longest linear dimension at the level of interest, weight, lean body weight, body mass index, and body surface area. Detector configuration, patient sizes, and image noise levels that resulted in unacceptable image quality and artifact rankings (score of 4 or higher) were determined by using multivariate logistic regression. Results: A 14 x 1.2-mm detector configuration resulted in fewer images with unacceptable quality than did the 64 x 0.6-mm configuration at all anatomic levels (P = .004, .01, and .02 for liver, pancreas, and kidneys, respectively). Image acceptability for the kidneys and ileum was significantly greater than that for the liver for all readers and detector configurations (P < .001). For the 14 3 1.2-mm detector configuration, patient longest linear dimensions yielding acceptable image quality across readers ranged from 34.9 to 35.8 cm at the four anatomic levels. Conclusion: An 80-kV abdominal CT can be performed with appropriate diagnostic quality in a substantial percentage of the population, but it is not recommended beyond the described patient size for each anatomic level. The 14 x 1.2-mm detector configuration should be preferred. (C)RSNA, 2010
引用
收藏
页码:732 / 742
页数:11
相关论文
共 30 条
[1]
EHMAN E, 2010, ABD RAD COURS SOC GA
[2]
Image mottle in abdominal CT [J].
Ende, JF ;
Huda, W ;
Ros, PR ;
Litwiler, AL .
INVESTIGATIVE RADIOLOGY, 1999, 34 (04) :282-286
[3]
EUSEMANN C, 2009, P SPIE MED IMAGING 2, V7258
[4]
Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis? [J].
Fletcher, Joel G. ;
Takahashi, Naoki ;
Hartman, Robert ;
Guimaraes, Luis ;
Huprich, James E. ;
Hough, David M. ;
Yu, Lifeng ;
McCollough, Cynthia H. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) :41-+
[5]
First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[6]
Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: Phantom study [J].
Funama, Y ;
Awai, K ;
Nakayama, Y ;
Kakei, K ;
Nagasue, N ;
Shimamura, M ;
Sato, N ;
Sultana, S ;
Morishita, S ;
Yamashita, Y .
RADIOLOGY, 2005, 237 (03) :905-910
[7]
Dual energy CT: preliminary observations and potential clinical applications in the abdomen [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Chandarana, Hersh ;
Macari, Michael .
EUROPEAN RADIOLOGY, 2009, 19 (01) :13-23
[8]
GUIMARAES L, 2009, RAD SOC N AM SCI ASS, P538
[9]
Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[10]
Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise [J].
Hsieh, J .
MEDICAL PHYSICS, 1998, 25 (11) :2139-2147