Transjugular intrahepatic portosystemic shunts: Assessment with helical CT angiography

被引:11
作者
Chopra, S
Ghiatas, AA
Encarnacion, CE
Esola, CC
Chintapalli, KN
Palmaz, JC
Dodd, GD
机构
[1] Department of Radiology, Univ. Texas Hlth. Sci. Ctr. S. A., San Antonio, TX 78284-7800
关键词
computed tomography (CT); angiography; helical; hypertension; portal; liver; interventional procedure; shunts; portosystemic; stents and prostheses;
D O I
10.1148/radiology.202.1.8988224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate diagnostic computed tomographic (CT) angiograms of transjugular intrahepatic portosystemic shunts (TIPS), helical CT angiography was performed in 10 patients with (n = 7) or without (n = 3) shunt dysfunction. CT angiography was performed with 3-mm-thick sections, pitch of 1, 120 kV, and 180-220 mA, after injection of 150 mi nonionic contrast material at 5 mL/sec, with a 50-second scanning delay after initiation of injection. All patients underwent transjugular portography within 1 week after CT angiography. In all cases, CT angiography correctly showed the presence or absence of the abnormality. These preliminary data suggest that CT angiography can provide diagnostic images of normal and abnormal TIPS.
引用
收藏
页码:277 / 280
页数:4
相关论文
共 12 条
[1]   HEPATIC CT ENHANCEMENT - A METHOD TO DEMONSTRATE REPRODUCIBILITY [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM ;
DODD, GD ;
MILLER, WJ ;
CONFER, SR .
RADIOLOGY, 1993, 188 (03) :627-631
[2]   TRANSJUGULAR INTRAHEPATIC PORTAL-SYSTEMIC SHUNTS - THE STATE-OF-THE-ART [J].
CONN, HO .
HEPATOLOGY, 1993, 17 (01) :148-158
[3]   DETECTION OF TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT DYSFUNCTION - VALUE OF DUPLEX-DOPPLER SONOGRAPHY [J].
DODD, GD ;
ZAJKO, AB ;
ORONS, PD ;
MARTIN, MS ;
EICHNER, LS ;
SANTAGUIDA, LA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1119-1124
[4]   COLOR DOPPLER SONOGRAPHY OF TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNTS (TIPS) [J].
FOSHAGER, MC ;
FERRAL, H ;
FINLAY, DE ;
CASTANEDAZUNIGA, WR ;
LETOURNEAU, JG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) :105-111
[5]   COMPLICATIONS OF TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT - A COMPREHENSIVE REVIEW [J].
FREEDMAN, AM ;
SANYAL, AJ ;
TISNADO, J ;
COLE, PE ;
SHIFFMAN, ML ;
LUKETIC, VA ;
PURDUM, PP ;
DARCY, MD ;
POSNER, MP .
RADIOGRAPHICS, 1993, 13 (06) :1185-1210
[6]   DETERMINATION OF OPTIMAL TIME WINDOW FOR LIVER SCANNING WITH CT DURING ARTERIAL PORTOGRAPHY [J].
GRAF, O ;
DOCK, WI ;
LAMMER, J ;
THURNHER, S ;
EIBENBERGER, KL ;
WILDLING, R ;
NIEDERLE, B ;
LANG, EK ;
LECHNER, G .
RADIOLOGY, 1994, 190 (01) :43-47
[7]   TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT - ANGIOGRAPHIC FOLLOW-UP AND SECONDARY INTERVENTIONS [J].
HAUSEGGER, KA ;
STERNTHAL, HM ;
KLEIN, GE ;
KARAIC, R ;
STAUBER, R ;
ZENKER, G .
RADIOLOGY, 1994, 191 (01) :177-181
[8]   SPIRAL(HELICAL) CT [J].
HEIKEN, JP ;
BRINK, JA ;
VANNIER, MW .
RADIOLOGY, 1993, 189 (03) :647-656
[9]   HELICAL CT ANGIOGRAPHY WITH MULTIPLANAR REFORMATION TECHNIQUES AND CLINICAL-APPLICATIONS [J].
IBUKURO, K ;
CHARNSANGAVEJ, C ;
CHASEN, MH ;
CINQUALBRE, AB ;
HERRON, DH ;
ROBINSON, TJ ;
WALLACE, S .
RADIOGRAPHICS, 1995, 15 (03) :671-682
[10]   CT ANGIOGRAPHY WITH SPIRAL CT AND MAXIMUM INTENSITY PROJECTION [J].
NAPEL, S ;
MARKS, MP ;
RUBIN, GD ;
DAKE, MD ;
MCDONNELL, CH ;
SONG, SM ;
ENZMANN, DR ;
JEFFREY, RB .
RADIOLOGY, 1992, 185 (02) :607-610