Determination of environmental estrogens in human urine by high performance liquid chromatography after fluorescent derivatization with p-nitrobenzoyl chloride

被引:94
作者
Mao, LH [1 ]
Sun, CJ [1 ]
Zhang, H [1 ]
Li, YX [1 ]
Wu, DS [1 ]
机构
[1] Sichuan Univ, W China Sch Publ Hlth, Chengdu 610041, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
HPLC; environmental estrogens; bisphenol A; 4-nonylphenol; solid phase extraction (SPE); precolumn fluorescent derivatization; human urine; p-nitrobenzoyl chloride; fluorescence detection;
D O I
10.1016/j.aca.2004.04.071
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high performance liquid chromatographic method (HPLC) for the simultaneous determination of 4-nonylphenol, bisphenol A, 17alpha-ethinylestradiol and three endogenic estrogens including 17alpha-estradiol, 17beta-estradiol, estriol in urine sample, based on precolumn derivatization with p-nitrobenzoyl chloride, is presented in this paper. The estrogens mentioned above in urine were firstly hydrolyzed with 0.6 mol/l HCl, and then enriched and cleaned-up by ENV-18 C18 solid phase extraction (SPE) column. The estrogens on column were eluted with dichloromethane, and the eluent was evaporated to dryness under gentle nitrogen flow. The residue was allowed to react with p-nitrobenzoyl chloride at 25 degreesC for 30 min. Separation was performed on a C18 column with gradient elution using acetonitrile and water as mobile phase. A fluorescence detection system was used to detect the fluorescent derivatization products. The detection limit of the method was 2.7 mug/l for bisphenol A and 17beta-estradiol, 2.9 mug/l for 4-nonylphenol, 4.6 mug/l for 17alpha-estradiol and 17alpha-ethinylestradiol and 8.3 mug/l for estriol, respectively. The relative standard deviations (R.S.D.) ranged from 1.29 to 4.52% and the recoveries ranged from 85.5 to 99.9%. The method was applied to the determination of those six estrogens mentioned above in human urine samples collected from 20 healthy volunteers (aged 21-29). Bisphenol A (BPA) and 4-nonylphenol (NP) were detected with average contents of 1.22 +/- 1.38 mg/l and 0.38 +/- 0.77 mg/l in 10 male urine samples and 1.29 +/- 1.22 mg/l and 0.05 +/- 0.05 mg/l in 10 female urine samples, respectively. 17alpha-ethinylestradiol (alpha-EE2) was also detected with average contents of 0.13 +/- 0.41 mg/l and 0.06 +/- 0.15 mg/l in male and female urine samples, respectively. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 246
页数:6
相关论文
共 19 条
[1]  
BROTONS JA, 1995, ENV HLTH PERSPECT, V103, P668
[2]   Simultaneous determination of estrogenic short ethoxy chain nonylphenols and their acidic metabolites in water by an in-sample derivatization/solid-phase microextraction method [J].
Díaz, A ;
Ventura, F ;
Galceran, MT .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3869-3876
[3]   Determination of 4-nonylphenol and 4-octylphenol in human blood samples by high-performance liquid chromatography with multi-electrode electrochemical coulometric-array detection [J].
Inoue, K ;
Yoshimura, Y ;
Makino, T ;
Nakazawa, H .
ANALYST, 2000, 125 (11) :1959-1961
[4]   Measurement of 4-nonylphenol and 4-tert-octylphenol in human urine by column-switching liquid chromatography-mass spectrometry [J].
Inoue, K ;
Kawaguchi, M ;
Okada, F ;
Takai, N ;
Yoshimura, Y ;
Horie, M ;
Izumi, S ;
Makino, T ;
Nakazawa, H .
ANALYTICA CHIMICA ACTA, 2003, 486 (01) :41-50
[5]  
JULIE AR, 2000, J CHROMATOGR B, V744, P157
[6]   DETERMINATION OF ESTROGENS IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AFTER PRECOLUMN DERIVATIZATION WITH 2-(4-CARBOXYPHENYL)-5,6-DIMETHYLBENZIMIDAZOLE [J].
KATAYAMA, M ;
TANIGUCHI, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 616 (02) :317-322
[7]  
Laganà A, 2000, RAPID COMMUN MASS SP, V14, P401, DOI 10.1002/(SICI)1097-0231(20000331)14:6<401::AID-RCM883>3.0.CO
[8]  
2-7
[9]   Simultaneous determination of 4-nonylphenol and bisphenol a in sewage sludge [J].
Meesters, RJW ;
Schröder, HF .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3566-3574
[10]   Determination of the xenoestrogens 4-nonylphenol and bisphenol A by high-performance liquid chromatography and fluorescence detection after derivatisation with dansyl chloride [J].
Naassner, M ;
Mergler, M ;
Wolf, K ;
Schuphan, I .
JOURNAL OF CHROMATOGRAPHY A, 2002, 945 (1-2) :133-138