A Glucose Biosensor Based on Deposition of Glucose Oxidase onto Crystalline Gold Nanoparticle Modified Carbon Nanotube Electrode

被引:98
作者
Rakhi, Raghavan Baby [1 ,2 ]
Sethupathi, Kanikrishnan [2 ]
Ramaprabhu, Sundara [1 ]
机构
[1] Indian Inst Technol, Alternat Energy & Nanotechnol Lab, NFMTC, Madras 600036, Tamil Nadu, India
[2] Indian Inst Technol, Dept Phys, Low Temp Lab, Madras 600036, Tamil Nadu, India
关键词
COLLOIDAL GOLD; IMMOBILIZATION; PALLADIUM; FILMS;
D O I
10.1021/jp810235v
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A new amperometric biosensor, based on deposition of glucose oxidase (GOD) onto crystalline gold (Au) nanoparticle modified multiwalled carbon nanotube (MWNT) electrode, is presented. NIWNTs have been synthesized by catalytic chemical vapor decomposition of acetylene over rare-earth-based AB(2) (DyNi2) alloy hydride catalyst. Purified MWNTs have been decorated with nanocrystalline Au metal clusters using a simple chemical reduction method. The characterization of metal-decorated CNTs has been done using X-ray diffraction analysis, scanning electron microscopy, transmission electron microscopy (TEM), high-resolution TEM, and energy-dispersive X-ray analysis. Amperometric biosensor fabricated by depositing GOD over Nafion-solubilized Au-MWNT electrode retains its biocatalytic activity and offers fast and sensitive glucose quantification. The performance of the biosensor has been studied using cyclic voltammetry, amperometry, and hydrodynamic voltammetry, and the results have been discussed. The fabricated glucose biosensor exhibits a linear response up to 22 mM glucose and a detection limit of 20 mu M.
引用
收藏
页码:3190 / 3194
页数:5
相关论文
共 19 条
[1]   FLOW-INJECTION ANALYSIS OF GLUCOSE AT AN AMPEROMETRIC GLUCOSE SENSOR-BASED ON ELECTROCHEMICAL CODEPOSITION OF PALLADIUM AND GLUCOSE-OXIDASE ON A GLASSY-CARBON ELECTRODE [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :17-23
[2]   Development of a PPO-poly(amphiphilic pyrrole) electrode for on site monitoring of phenol in aqueous effluents [J].
Cosnier, S ;
Fombon, JJ ;
Labbé, P ;
Limosin, D .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 59 (2-3) :134-139
[3]   ORGANIZATION OF AU COLLOIDS AS MONOLAYER FILMS ONTO ITO GLASS SURFACES - APPLICATION OF THE METAL COLLOID FILMS AS BASE INTERFACES TO CONSTRUCT REDOX-ACTIVE MONOLAYERS [J].
DORON, A ;
KATZ, E ;
WILLNER, I .
LANGMUIR, 1995, 11 (04) :1313-1317
[4]   Electrochemical characterization of glassy carbon electrodes modified by resol mixtures [J].
García, CD ;
De Pauli, CP ;
Ortiz, PI .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 510 (1-2) :115-119
[5]   CRYSTAL-STRUCTURE OF GLUCOSE-OXIDASE FROM ASPERGILLUS-NIGER REFINED AT 2 .3 ANGSTROM RESOLUTION [J].
HECHT, HJ ;
KALISZ, HM ;
HENDLE, J ;
SCHMID, RD ;
SCHOMBURG, D .
JOURNAL OF MOLECULAR BIOLOGY, 1993, 229 (01) :153-172
[6]   HELICAL MICROTUBULES OF GRAPHITIC CARBON [J].
IIJIMA, S .
NATURE, 1991, 354 (6348) :56-58
[7]   A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode [J].
Lim, SH ;
Wei, J ;
Lin, JY ;
Li, QT ;
KuaYou, J .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (11) :2341-2346
[8]   Application of colloidal gold in protein immobilization, electron transfer, and biosensing [J].
Liu, SQ ;
Leech, D ;
Ju, HX .
ANALYTICAL LETTERS, 2003, 36 (01) :1-19
[9]   Electrochemical biosensors based on colloidal gold-carbon nanotubes composite electrodes [J].
Manso, J. ;
Mena, M. L. ;
Yanez-Sedeno, P. ;
Pingarron, J. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 603 (01) :1-7
[10]  
Miscoria SA, 2002, ELECTROANAL, V14, P981, DOI 10.1002/1521-4109(200208)14:14<981::AID-ELAN981>3.0.CO