A simple and rapid high-performance liquid chromatographic (HPLC) method for 5-fluorouracil (5-FU) assay in plasma and possible detection of patients with impaired dihydropyrimidine dehydrogenase (DPD) activity

被引:86
作者
Ciccolini, J
Mercier, C
Blachon, MF
Favre, R
Durand, A
Lacarelle, B
机构
[1] CHU Timone, Federat Pharmacol Clin & Pharmacocinet, F-13385 Marseille 05, France
[2] La Timone Univ Hosp, Med Oncol Serv, Marseille, France
关键词
5-fluorouracil; dihydropyrimidine dehydrogenase; HPLC; pharmacokinetics; uracil/dihydrouracil ratio;
D O I
10.1111/j.1365-2710.2004.00569.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Dihydropyrimidine dehydrogenase (DPD) gene polymorphism may lead to severe toxicity with 5-fluorouracil (5-FU), a major anticancer drug extensively used in clinical oncology. Drug monitoring combined with early detection of patients at risk would enable timely dose adaptation so as to maintain drug concentrations within a therapeutic window. However, the best method to identify such patients remains to be determined. Objective: The aim of this study was to develop a rapid and simple high-performance liquid chromatographic (HPLC) method for estimating uracil/dihydrouracil (U/UH2) ratio in plasma, as an index of DPD status, and for assaying 5-FU as part of drug level monitoring. Method: Assay of 5-FU, and U/UH2 detection were performed on a HPLC system equipped with UV detector. Analytes were separated at room temperature using a 5 mum particles, 25 cm RP-18 X-Terra column. The mobile-phase consisted of a KH2PO4 salt solution (0(.)05 m) + 0(.)1% triethylamine (TEA) pumped at 0(.)4 mL/min. Detection of 5-FU and 5-bromouracil were performed at 254 nm; U and UH2 elution was monitored at 210 nm. Results: The method was sensitive and specific for assaying 5-FU within the 5-500 ng/mL concentration range, which covers exposure levels currently met in clinical practice. The method was simple, and relatively cheap, and rapid, with an analytical run time of about 30 min. Data from a patient with 5-FU toxicity suggest that the method was capable of identifying DPD metabolic phenotype in cancer patients, based on measurement of plasma U/UH2 ratio. Conclusion: The method described should be suitable both for detecting patients at high risk of 5-FU toxicity, and for drug level monitoring during chemotherapy.
引用
收藏
页码:307 / 315
页数:9
相关论文
共 42 条
  • [1] Simultaneous HPLC determination of 5-fluorouracil and its metabolites in plasma of cancer patients
    Casale, F
    Canaparo, R
    Muntoni, E
    Serpe, L
    Zara, GP
    Pepa, CD
    Berno, E
    Costa, M
    Eandi, M
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2002, 16 (07) : 446 - 452
  • [2] High-performance liquid chromatographic assay with ultraviolet detection for quantification of dihydrofluorouracil in human lymphocytes:: application to measurement of dihydropyrimidine dehydrogenase activity
    Déporte-Féty, R
    Picot, M
    Amiand, M
    Moreau, A
    Campion, L
    Lanoë, D
    Renée, N
    Milano, G
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 762 (02): : 203 - 209
  • [3] Relationship between plasma concentrations of 5-fluorouracil and 5-fluoro-5,6-dihydrouracil and toxicity of 5-fluorouracil infusions in cancer patients
    Di Paolo, A
    Ibrahim, T
    Danesi, R
    Maltoni, M
    Vannozzi, F
    Flamini, E
    Zoli, W
    Amadori, D
    Del Tacca, M
    [J]. THERAPEUTIC DRUG MONITORING, 2002, 24 (05) : 588 - 593
  • [4] Diasio R B, 1995, Cancer Treat Res, V78, P71
  • [5] Diasio RB, 1998, ONCOLOGY-NY, V12, P23
  • [6] Simple and sensitive determination of 5-fluorouracil in plasma by high-performance liquid chromatography -: Application to clinical pharmacokinetic studies
    Escoriaza, J
    Aldaz, A
    Calvo, E
    Giráldez, J
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 736 (1-2): : 97 - 102
  • [7] ETIENNE MC, 1993, CLIN CHEM, V39, P82
  • [8] Ezzeldin H, 2003, CLIN CANCER RES, V9, P3021
  • [9] Mutational analysis of the human dihydropyrimidine dehydrogenase gene by denaturing high-performance liquid chromatography
    Fischer, J
    Schwab, M
    Eichelbaum, M
    Zanger, UM
    [J]. GENETIC TESTING, 2003, 7 (02): : 97 - 105
  • [10] Correlation between uracil and dihydrouracil plasma ratio, fluorouracil (5-FU) pharmacokinetic parameters, and tolerance in patients with advanced colorectal cancer:: A potential interest for predicting 5-FU toxicity and determining optimal 5-FU dosage
    Gamelin, E
    Boissdron-Celle, M
    Guérin-Meyer, V
    Delva, R
    Lortholary, A
    Genevieve, F
    Larra, F
    Ifrah, N
    Robert, J
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 1999, 17 (04) : 1105 - 1110