Slit-lamp-adapted optical coherence tomography of the anterior segment

被引:105
作者
Hoerauf, H
Wirbelauer, C
Scholz, C
Engelhardt, R
Koch, P
Laqua, H
Birngruber, R
机构
[1] Univ Lubeck, Dept Ophthalmol, D-23538 Lubeck, Germany
[2] Med Laser Ctr Lubeck, Lubeck, Germany
关键词
D O I
10.1007/s004170050002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the diagnostic potential of a slit-lamp-adapted optical coherence tomography (OCT) system as an in vivo imaging device for routine clinical examination of the anterior segment of the eve. Patients and methods: In a pilot study, healthy volunteers and patients with different pathologies of the anterior segment were examined with a slit-lamp-adapted OCT system using 100-200 axial scans with 100-Hz line-scan frequency. The scan length is variable up to 7 mm, and the axial depth is 1.5 mm in tissue. Results: The slit-lamp-adapted OCT system allowed direct biomicroscopic imaging of the measured area. Anatomic structures and morphological changes anterior to the attenuating iris pigment epithelium could be visualized with high accuracy, Biometric analyses of the cornea, the chamber angle, the iris and secondary cataract were possible. Complete demonstration of the chamber angle was difficult clue to the backscattering properties of the anterior part of the sclera and the consequent shadowing of the most peripheral part of the iris. Conclusions: Slit-lamp-adapted OCT is a diagnostic tool which allows in vivo microscopic cross-sectional imaging of the anterior segment and precise measurement of ocular structures.
引用
收藏
页码:8 / 18
页数:11
相关论文
共 19 条
[1]  
AUFFARTH GU, 1998, 11 K DGII 1997, P125
[2]  
BECKER SC, 1972, CLIN GONIOSCOPY TEXT, P73
[3]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[4]   OPTICAL BIOPSY AND IMAGING USING OPTICAL COHERENCE TOMOGRAPHY [J].
FUJIMOTO, JG ;
BREZINSKI, ME ;
TEARNEY, GJ ;
BOPPART, SA ;
BOUMA, B ;
HEE, MR ;
SOUTHERN, JF ;
SWANSON, EA .
NATURE MEDICINE, 1995, 1 (09) :970-972
[5]   Topography of diabetic macular edema with optical coherence tomography [J].
Hee, MR ;
Puliafito, CA ;
Duker, JS ;
Reichel, E ;
Coker, JG ;
Wilkins, JR ;
Schuman, JS ;
Swanson, EA ;
Fujimoto, JG .
OPHTHALMOLOGY, 1998, 105 (02) :360-370
[6]   BIOMETRY OF THE ANTERIOR EYE SEGMENT BY SCHEIMPFLUG PHOTOGRAPHY [J].
HOCKWIN, O ;
WEIGELIN, E ;
LASER, H ;
DRAGOMIRESCU, V .
OPHTHALMIC RESEARCH, 1983, 15 (02) :102-108
[7]   MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY [J].
IZATT, JA ;
HEE, MR ;
SWANSON, EA ;
LIN, CP ;
HUANG, D ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) :1584-1589
[8]  
Koop N, 1997, OPHTHALMOLOGE, V94, P481, DOI 10.1007/s003470050143
[9]  
LIEBMANN JM, 1986, J AM OPTOM ASSOC, V67, P469
[10]   High-resolution magnetic resonance imaging of the intraorbital optic nerve and subarachnoid space in patients with papilledema and optic atrophy [J].
Mashima, Y ;
Oshitari, K ;
Imamura, Y ;
Momoshima, S ;
Shiga, H ;
Oguchi, Y .
ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (10) :1197-1203