Two-dimensional scatter integration method for brachytherapy dose calculations in 3D geometry

被引:17
作者
Kirov, AS
Williamson, JF
机构
[1] Radiation Oncology Center, Mallinckrodt Institute of Radiology, Washington Univ. School of Medicine, St Louis, MO 63110
关键词
D O I
10.1088/0031-9155/42/11/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In brachytherapy clinical practice, applicator shielding and tissue heterogeneities are usually not explicitly taken into account. None of the existing dose computational methods are able to reconcile accurate dose calculation in complex three-dimensional (3D) geometries with high efficiency and simplicity. We propose a new model that performs two-dimensional integration of the scattered dose component. The model calculates the effective primary dose at the point of interest and estimates the scatter dose as a superposition of the scatter contributions from pyramid-shaped minibeams. The approach generalizes a previous scatter subtraction model designed to calculate the dose for axial points in simple cylindrically symmetric geometry by dividing the scattering volume into spatial regions coaxial with the source-to-measurement point direction. To allow for azimuthal variation of the primary dose, these minibeams were divided into equally spaced azimuthally distributed pyramidal volumes. The model uses precalculated scatter-to-primary ratios (SPRs) for collimated isotropic sources. Effective primary dose, which includes the radiation scattered in the source capsule, is used to achieve independence from the source structure. For realistic models of the Ir-192 HDR and PDR sources, the algorithm agrees with Monte Carlo within 2.5% and for the I-125 type 6702 seed within 6%. The 2D scatter integration (2DSI) model has the potential to estimate the dose behind high-density heterogeneities both accurately and efficiently. The algorithm is much faster than Monte Carlo methods and predicts the dose around sources with different gamma-ray energies and differently shaped capsules with high accuracy.
引用
收藏
页码:2119 / 2135
页数:17
相关论文
共 31 条
[1]  
Clarkson JR., 1941, BRIT J RADIOL, V14, P265, DOI DOI 10.1259/0007-1285-14-164-265
[2]  
DAS RK, 1996, INT J RADIAT ONCOL, V38, P843
[3]  
DILLMAN LT, 1975, 10 MIRD
[4]  
GLASGOW G P, 1979, Medical Physics (Woodbury), V6, P49, DOI 10.1118/1.594551
[5]   TLD, diode and monte carlo dosimetry of an Ir-192 source for high dose-rate brachytherapy [J].
Kirov, AS ;
Williamson, JF ;
Meigooni, AS ;
Zhu, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12) :2015-2036
[6]   Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields [J].
Kirov, AS ;
Williamson, JF ;
Meigooni, AS ;
Zhu, Y .
MEDICAL PHYSICS, 1996, 23 (06) :911-919
[7]   QUANTITATIVE VERIFICATION OF IR-192 PDR AND HDR SOURCE STRUCTURE BY PINHOLE AUTORADIOGRAPHY [J].
KIROV, AS ;
MEIGOONI, AS ;
ZHU, Y ;
VALICENTI, RK ;
WILLIAMSON, JF .
MEDICAL PHYSICS, 1995, 22 (11) :1753-1757
[8]  
KIROV AS, 1996, MED PHYS, V23, P1056
[9]  
LATHROP KD, 1972, REACT TECHNOL, V15, P107
[10]   MONTE-CARLO CALCULATION OF KERMA TO A POINT IN THE VICINITY OF MEDIA INTERFACES [J].
LI, ZF ;
WILLIAMSON, JF ;
PERERA, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (12) :1825-1840