POWER CONVERTERS;
4-LEG INVERTER;
LOAD;
MODULATOR;
SYSTEMS;
SINGLE;
VSI;
D O I:
10.1049/iet-pel.2013.0121
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
This study deals with a newly-conceived voltage control method for three-phase four-leg voltage source inverters (VSIs) which are being required in autonomous power generating units devoted to supply both three-phase and single-phase electrical loads in four-wire electric power distribution systems. To deal with VSI operating conditions providing three-phase voltage supply of both unbalanced loads and non-linear loads, an integral + resonant (I + R) voltage control structure is discussed and experimentally verified by means of a 25 kVA rated power converter prototype. It is shown that the proposed voltage control allows simplifying the overall control configuration, achieving zero-overhead power factor regulation and fast compensation of load unbalances. Further to that, a complete current limiting strategy is described and tested under different load conditions.