High-throughput liquid chromatography-tandem mass spectrometry determination of bupropion and its metabolites in human, mouse and rat plasma using a monolithic column

被引:66
作者
Borges, V
Yang, E
Dunn, J
Henion, J
机构
[1] Cornell Univ, Dept Populat Med & Diagnost Sci, Ithaca, NY 14850 USA
[2] GlaxoSmithKline Pharm, DMPK, Worldwide Bioanal, Res Triangle Pk, NC 27709 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2004年 / 804卷 / 02期
关键词
bupropion; hydroxybupropion; threo-hydrobupropion;
D O I
10.1016/j.jchromb.2004.01.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work, a high-throughput LC/MS/MS method using a Chromolith RP-18 (50 mm x 4.6 mm) monolithic column was developed and partially validated for the determination of bupropion (BUP), an anti-depressant drug, and its metabolites, hydroxybupropion and threo-hydrobupropion (TB), in human, mouse, and rat plasma. A modem integrated liquid chromatograph and an LC/MS/MS system with a TurboIonSpray (TIS) interface were used for the positive electrospray selected reaction monitoring (SRM) LC/MS analyses. Spiked control plasma calibration standards and quality control (QC) samples were extracted by semi-automated 96-well liquid-liquid extraction (LLE) using ethyl acetate. A mobile phase consisting of 8 mM ammonium acetate-acetonitrile (55:45, v/v) delivered isocratically at 5 ml/min, and split post-column to 2 ml/min directed to the TIS, provided the optimum conditions for the chromatographic separation of bupropion and its metabolites within 23 s. The isotope-labeled D-6-bupropion and D-6-hydroxybupropion were used as internal standards. The method was linear over a concentration range of 0.25-200 ng/ml (bupropion and threo-hydrobupropion), and 1.25-1000 ng/ml (hydroxybupropion). The intra- and inter-day assay accuracy and precision were within 15% for all analytes in each of the biological matrices. The monolithic column performance as a function of column backpressure, peak asymmetry, and retention time reproducibility was adequately maintained over 864 extracted plasma injections. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:277 / 287
页数:11
相关论文
共 27 条
  • [1] High-throughput selected reaction monitoring liquid chromatography-mass spectrometry determination of methylphenidate and its major metabolite, ritalinic acid, in rat plasma employing monolithic columns
    Barbarin, N
    Mawhinney, DB
    Black, R
    Henion, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (01): : 73 - 83
  • [2] Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.3.CO
  • [3] 2-S
  • [4] Dear G, 2001, RAPID COMMUN MASS SP, V15, P152, DOI 10.1002/1097-0231(20010130)15:2<152::AID-RCM206>3.3.CO
  • [5] 2-R
  • [6] High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma
    Deng, Y
    Wu, JT
    Lloyd, TL
    Chi, CL
    Olah, TV
    Unger, SE
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (11) : 1116 - 1123
  • [7] Faucette SR, 2000, DRUG METAB DISPOS, V28, P1222
  • [8] Hesse LM, 2000, DRUG METAB DISPOS, V28, P1176
  • [9] Direct plasma analysis of drug compounds using monolithic column liquid chromatograpy and tandem mass spectrometry
    Hsieh, Y
    Wang, GF
    Wang, YG
    Chackalamannil, S
    Kortmacher, WA
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (08) : 1812 - 1818
  • [10] Simultaneous determination of a drug candidate and its metabolite in rat plasma samples using ultrafast monolithic column high-performance liquid chromatography/tandem mass spectrometry
    Hsieh, Y
    Wang, GF
    Wang, YG
    Chackalamannil, S
    Brisson, JM
    Ng, K
    Korfmacher, WA
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (10) : 944 - 950