Occurrence and determination of herbicides and their major transformation products in environmental waters

被引:138
作者
Laganà, A
Bacaloni, A
De Leva, I
Faberi, A
Fago, G
Marino, A
机构
[1] Univ Roma La Sapienza, Dept Chem, I-00185 Rome, Italy
[2] DIPIA, ISPESI, I-00184 Rome, Italy
关键词
maize herbicides; grain herbicides; transformation products; environmental waters; HPLC/MS-MS;
D O I
10.1016/S0003-2670(02)00351-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the simultaneous determination of selected maize and grain herbicides (amidosulfuron, N-([{[(4,6-dimethoxy-2-pyrimidinyl)amino]carbonyl}amino)sulfonyl]-N-methylmethanesulfonamide; bentazone, 3-(1-methylethyl)-1H-2,1,3-benzothiadiazin-4(3H)-one2,2-dioxide; 2,4-D, (2,4-dichlorophenoxy)acetic acid; MCPA, (4-chloro-2-methylphenoxy)acetic acid; metosulam, N-(2,6'-dichloro-3-methylphenyl)-5,7-dimethoxy[1,2,4]triazolo[1,5-a]pyrimidine-2-sulfonamide) and their transformation products (TPs) (8-hydroxybentazone, 1H-2,1,3-benzothiadiazin-4(3H)-one,8-hydroxy-3-(1-methylethyl)-2, 2-dioxide; bifenox acid, 5-(2,4-dichlorophenoxy)-2-nitrobenzoic acid; clodinafop acid; 2,4-dichlorophenol; 4-chloro-2-methylphenol) in environmental waters was developed. The procedure combines a solid-phase extraction (SPE) with column liquid chromatography-tandem mass spectrometry detection utilizing a pneumatically assisted and heat-assisted electrospray interface in negative mode. The extraction of analytes from filtered drainage or river water samples was performed using as sorbent a graphitized carbon. The recovery, for drinking water, ranged from 91 to 98%, and from 84 to 95% for river water. Excellent method precision was demonstrated with percent relative standard deviation of less than 10% for all analytes at fortification level. Detection limits were at level of few nanograms per liter, except for 2,4-dichlorophenol and 4-chloro-2-methylphenol, that was in the range of tens of nanogram per liter. The present methodology was used for searching in river and drainage waters of maize-grain fields of the Tiber valley, during a typical period of herbicides application from April to July 2001. The levels detected of four compounds were in the range of: non-detectable (ND)-6.1, ND-27, ND-1.9 and ND-0.5 mug l(-1), for MCPA, bentazone, 8-hydroxybentazone and 2,4-D, respectively. Detectable amounts of bentazone-8-hydroxy at level of 0,3 mug l(-1) was found to be transported into river. The highly satisfactory results for all target analytes demonstrate the potential of liquid chromatography-tandem mass spectrometry for the identification and the quantification of the polar and acidic herbicides at below 100 ng l(-1) levels. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:187 / 198
页数:12
相关论文
共 31 条
[1]   Monitoring of pesticides in river water based on samples previously stored in polymeric cartridges followed by on-line solid-phase extraction liquid chromatography diode array detection and confirmation by atmospheric pressure chemical ionization mass spectrometry [J].
Aguilar, C ;
Ferrer, I ;
Borrull, F ;
Marcé, RM ;
Barceló, D .
ANALYTICA CHIMICA ACTA, 1999, 386 (03) :237-248
[2]   DETERMINATION OF BENZENESULFONATES AND NAPHTHALENESULFONATES IN WASTE-WATER BY SOLID-PHASE EXTRACTION WITH GRAPHITIZED CARBON-BLACK AND ION-PAIR LIQUID-CHROMATOGRAPHY WITH UV DETECTION [J].
ALTENBACH, B ;
GIGER, W .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2325-2333
[3]   Monitoring natural and synthetic estrogens at activated sludge sewage treatment plants and in a receiving river water [J].
Baronti, C ;
Curini, R ;
D'Ascenzo, G ;
Di Corcia, A ;
Gentili, A ;
Samperi, R .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (24) :5059-5066
[4]   Mechanistic aspects of electrospray ionization [J].
Bruins, AP .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :345-357
[5]   DETERMINATION OF PHENOXYALKANOIC ACIDS AND OTHER ACIDIC HERBICIDES AT THE LOW PPT LEVEL IN WATER APPLYING SOLID-PHASE EXTRACTION WITH RP-C-18 MATERIAL [J].
BUTZ, S ;
HEBERER, T ;
STAN, HJ .
JOURNAL OF CHROMATOGRAPHY A, 1994, 677 (01) :63-74
[6]   AUTOMATED ONLINE LIQUID-SOLID EXTRACTION FOLLOWED BY LIQUID CHROMATOGRAPHY-HIGH-FLOW PNEUMATICALLY ASSISTED ELECTROSPRAY MASS-SPECTROMETRY FOR THE DETERMINATION OF ACIDIC HERBICIDES IN ENVIRONMENTAL WATERS [J].
CHIRON, S ;
PAPILLOUD, S ;
HAERDI, W ;
BARCELO, D .
ANALYTICAL CHEMISTRY, 1995, 67 (09) :1637-1643
[7]   Solid-phase extraction followed by high-performance liquid chromatography-ionspray interface-mass spectrometry for monitoring of herbicides in environmental water [J].
Curini, R ;
Gentili, A ;
Marchese, S ;
Marino, A ;
Perret, D .
JOURNAL OF CHROMATOGRAPHY A, 2000, 874 (02) :187-198
[8]   SIMULTANEOUS DETERMINATION OF VARIOUS PESTICIDES IN WATER BY SOLID-PHASE EXTRACTION HPLC WITH PHOTODIODE-ARRAY DETECTION [J].
DELACOLINA, C ;
BAEZ, ME ;
PENA, A ;
ROMERO, E ;
DIOS, G ;
SANCHEZRASERO, F .
SCIENCE OF THE TOTAL ENVIRONMENT, 1994, 153 (1-2) :1-6
[9]   GRAPHITIZED CARBON-BLACK EXTRACTION CARTRIDGES FOR MONITORING POLAR PESTICIDES IN WATER [J].
DICORCIA, A ;
SAMPERI, R ;
MARCOMINI, A ;
STELLUTO, S .
ANALYTICAL CHEMISTRY, 1993, 65 (07) :907-912
[10]  
*EEC, 1988, OFFICIAL J