Jones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography

被引:129
作者
Jiao, SL [1 ]
Wang, LHV [1 ]
机构
[1] Texas A&M Univ, Opt Imaging Lab, Biomed Engn Program, College Stn, TX 77843 USA
关键词
optical coherence tomography; Jones matrix; Mueller matrix; biological tissue; soft tissue; polarization;
D O I
10.1117/1.1483878
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two-dimensional depth-resolved Jones-matrix images of scattering biological tissues were measured with novel double-source double-detector polarization-sensitive optical coherence tomography (OCT). The Jones matrix can be determined in a single scan with this OCT system. The experimental results show that this system can be effectively applied to the measurement of soft tissues, which are less stable than hard tissues. Polarization parameters such as diattenuation, birefringence, and orientation of the fast axis can be extracted through decomposition of the measured Jones matrix. The Jones matrix of thermally treated porcine tendon showed a reduction of birefringence from thermal damage. The Jones matrices of porcine skin and bovine cartilage also revealed that the density and orientation of the collagen fibers in porcine skin and bovine cartilage are not distributed as uniformly as in porcine tendon. Birefringence is sensitive to changes in tissue because it is based on phase contrast. (C) 2002 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:350 / 358
页数:9
相关论文
共 22 条
[1]  
BASKANSKY M, 2000, OPT LETT, V25, P545
[2]  
Chipman R. A., 1995, HDB OPTICS
[3]  
COLLETT E, 1993, POLARIZED LIGHT, pCH10
[4]   Imaging thermally damaged tissue by polarization sensitive optical coherence tomography [J].
de Boer, JF ;
Srinivas, SM ;
Malekafzali, A ;
Chen, ZP ;
Nelson, JS .
OPTICS EXPRESS, 1998, 3 (06) :212-218
[5]   Determination of the depth-resolved Stokes parameters of light backscattered from turbid media by use of polarization-sensitive optical coherence tomography [J].
de Boer, JF ;
Milner, TE ;
Nelson, JS .
OPTICS LETTERS, 1999, 24 (05) :300-302
[6]   Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography [J].
deBoer, JF ;
Milner, TE ;
vanGemert, MJC ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (12) :934-936
[7]   In vivo ultrahigh-resolution optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Kärtner, FX ;
Pitris, C ;
Boppart, SA ;
Li, XD ;
Ippen, EP ;
Fujimoto, JG .
OPTICS LETTERS, 1999, 24 (17) :1221-1223
[8]   Birefringence characterization of biological tissue by use of optical coherence tomography [J].
Everett, MJ ;
Schoenenberger, K ;
Colston, BW ;
Da Silva, LB .
OPTICS LETTERS, 1998, 23 (03) :228-230
[9]  
GIL JJ, 1987, OPTIK, V76, P67
[10]   Ultrahigh-resolution optical coherence tomography using continuum generation in an air-silica microstructure optical fiber [J].
Hartl, I ;
Li, XD ;
Chudoba, C ;
Ghanta, RK ;
Ko, TH ;
Fujimoto, JG ;
Ranka, JK ;
Windeler, RS .
OPTICS LETTERS, 2001, 26 (09) :608-610