In vivo ultrahigh-resolution optical coherence tomography

被引:833
作者
Drexler, W [1 ]
Morgner, U
Kärtner, FX
Pitris, C
Boppart, SA
Li, XD
Ippen, EP
Fujimoto, JG
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
关键词
D O I
10.1364/OL.24.001221
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Ultrahigh-resolution optical coherence tomography (OCT) by use of state of the art broad-bandwidth femtosecond laser technology is demonstrated and applied to in vivo subcellular imaging. Imaging is performed with a Kerr-lens mode-locked Ti:sapphire laser with double-chirped mirrors that emits sub-two-cycle pulses with bandwidths of up to 350 nm, centered at 800 nm. Longitudinal resolutions of similar to 1 mu m and transverse resolution of 3 mu m, with a 110-dB dynamic range, are achieved, in biological tissue. To overcome depth-of-field limitations we perform zone focusing and image fusion to construct a tomogram with high transverse resolution throughout the image depth. To our knowledge this is the highest longitudinal resolution demonstrated to date for in vivo OCT imaging. (C) 1999 Optical Society of America.
引用
收藏
页码:1221 / 1223
页数:3
相关论文
共 12 条
  • [1] SIGNAL AND RESOLUTION ENHANCEMENTS IN DUAL BEAM OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN EYE
    Baumgartner, Angela
    Hitzenberger, Christoph K.
    Sattmann, Harald
    Drexler, Wolfgang
    Fercher, Adolf F.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (01) : 45 - 54
  • [2] In vivo cellular optical coherence tomography imaging
    Boppart, SA
    Bouma, BE
    Pitris, C
    Southern, JF
    Brezinski, ME
    Fujimoto, JG
    [J]. NATURE MEDICINE, 1998, 4 (07) : 861 - 865
  • [3] HIGH-RESOLUTION OPTICAL COHERENCE TOMOGRAPHIC IMAGING USING A MODE-LOCKED TI-AL2O3 LASER SOURCE
    BOUMA, B
    TEARNEY, GJ
    BOPPART, SA
    HEE, MR
    BREZINSKI, ME
    FUJIMOTO, JG
    [J]. OPTICS LETTERS, 1995, 20 (13) : 1486 - 1488
  • [4] OPTICAL LOW COHERENCE REFLECTOMETRY WITH 1-BULLET-9 MU-M SPATIAL-RESOLUTION
    CLIVAZ, X
    MARQUISWEIBLE, F
    SALATHE, RP
    [J]. ELECTRONICS LETTERS, 1992, 28 (16) : 1553 - 1555
  • [5] OPTICAL BIOPSY AND IMAGING USING OPTICAL COHERENCE TOMOGRAPHY
    FUJIMOTO, JG
    BREZINSKI, ME
    TEARNEY, GJ
    BOPPART, SA
    BOUMA, B
    HEE, MR
    SOUTHERN, JF
    SWANSON, EA
    [J]. NATURE MEDICINE, 1995, 1 (09) : 970 - 972
  • [6] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [7] Dynamic coherent focus OCT with depth-independent transversal resolution
    Lexer, F
    Hitzenberger, CK
    Drexler, W
    Molebny, S
    Sattmann, H
    Sticker, M
    Fercher, AF
    [J]. JOURNAL OF MODERN OPTICS, 1999, 46 (03) : 541 - 553
  • [8] SPATIALLY COHERENT WHITE-LIGHT INTERFEROMETER BASED ON A POINT FLUORESCENT SOURCE
    LIU, HH
    CHENG, PH
    WANG, JP
    [J]. OPTICS LETTERS, 1993, 18 (09) : 678 - 680
  • [9] Sub-two-cycle pulses from a Kerr-lens mode-locked Ti:sapphire laser
    Morgner, U
    Kärtner, FX
    Cho, SH
    Chen, Y
    Haus, HA
    Fujimoto, JG
    Ippen, EP
    Scheuer, V
    Angelow, G
    Tschudi, T
    [J]. OPTICS LETTERS, 1999, 24 (06) : 411 - 413
  • [10] An optical coherence microscope with enhanced resolving power in thick tissue
    Schmitt, JM
    Lee, SL
    Yung, KM
    [J]. OPTICS COMMUNICATIONS, 1997, 142 (4-6) : 203 - 207