Efficacy of fibrinogen and prothrombin complex concentrate used to reverse dilutional coagulopathy - a porcine model

被引:104
作者
Fries, D.
Haas, T.
Klingler, A.
Streif, W.
Klima, G.
Martini, J.
Wagner-Berger, H.
Innerhofer, P.
机构
[1] Innsbruck Med Univ, Div Gen & Surg Intens Care Med, A-6020 Innsbruck, Austria
[2] Innsbruck Med Univ, Div Anaesthesiol, A-6020 Innsbruck, Austria
[3] Innsbruck Med Univ, Dept Theoret Surg, A-6020 Innsbruck, Austria
[4] Innsbruck Med Univ, Dept Paediat, A-6020 Innsbruck, Austria
[5] Innsbruck Med Univ, Dept Histol & Embryol, A-6020 Innsbruck, Austria
关键词
blood; prothrombin complex concentrate; complications; coagulopathy; haemorrhage; fluid; therapy; measurement techniques; Thrombelastograph; (R); pig; protein; fibrinogen concentrate;
D O I
10.1093/bja/ael191
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. This study was conducted to assess whether the combined administration of fibrinogen and prothrombin complex concentrate (PCC) enables the reversal of dilutional coagulopathy resulting from intended blood loss and fluid replacement, and whether this treatment reduces further blood loss and mortality. Methods. In 20 anaesthetized pigs, similar to 65% of the estimated blood volume was withdrawn and replaced with the same amount of hydroxyethyl starch (6% HES 130/0.4) to mimic blood loss and to develop a dilutional coagulopathy. Pigs (randomized) received either fibrinogen (200 mg kg(-1)) and PCC (35 IU kg(-1)) (n=10), or placebo (n=10). Thereafter, a standard liver laceration was performed to induce uncontrolled haemorrhage. The subsequent blood loss and survival time were determined as primary outcome variables. Throughout the experiment serial blood samples were obtained to assess the competence of the haemostatic system using standard coagulation tests, modified Thrombelastograph (R) measurements (ROTEM (R)) and electron microscopy clot imaging. Results. As compared with baseline, after haemodilution both groups showed statistically significant impairment of haemostasis as measured with standard coagulation tests and thrombelastography. These parameters significantly improved after administration of the study drugs while aPPT measurements remained unchanged. Blood loss after liver injury was significantly less in the treatment group as compared with placebo: 240 ml (50-830) vs 1800 ml (1500-2500) (P < 0.0001). All treated animals survived, whereas 80% of the placebo group died (P < 0.0001). Conclusion. During haemodilution, substitution of fibrinogen and PCC causes an enhancement of coagulation and final clot strength. This reversal of dilutional coagulopathy may reduce blood loss and mortality when large amounts of colloids are needed to maintain normovolaemia during huge blood losses.
引用
收藏
页码:460 / 467
页数:8
相关论文
共 32 条
[11]   HEMOSTATIC FACTORS AND REPLACEMENT OF MAJOR BLOOD-LOSS WITH PLASMA-POOR RED-CELL CONCENTRATES [J].
HIIPPALA, ST ;
MYLLYLA, GJ ;
VAHTERA, EM .
ANESTHESIA AND ANALGESIA, 1995, 81 (02) :360-365
[12]  
Huet RCGG, 2000, CAN J ANAESTH, V47, P1207
[13]   The effects of perioperatively administered colloids and crystalloids on primary platelet-mediated hemostasis and clot formation [J].
Innerhofer, P ;
Fries, D ;
Margreiter, J ;
Klingler, A ;
Kühbacher, G ;
Wachter, B ;
Oswald, E ;
Salner, E ;
Frischhut, B ;
Schobersberger, W .
ANESTHESIA AND ANALGESIA, 2002, 95 (04) :858-865
[14]   LABORATORY HEMOSTATIC ABNORMALITIES IN MASSIVELY TRANSFUSED PATIENTS GIVEN RED-BLOOD-CELLS AND CRYSTALLOID [J].
LESLIE, SD ;
TOY, PTCY .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1991, 96 (06) :770-773
[15]   Early use of recombinant factor VIIa improves mean arterial pressure and may potentially decrease mortality in experimental hemorrhagic shock: A pilot study [J].
Lynn, M ;
Jerokhimov, I ;
Jewelewicz, D ;
Popkin, C ;
Johnson, EW ;
Rashid, QN ;
Brown, M ;
Martinowitz, U .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 52 (04) :703-707
[16]   Molecular weight of hydroxyethyl starch: is there an effect on blood coagulation and pharmacokinetics? [J].
Madjdpour, C ;
Dettori, N ;
Frascarolo, P ;
Burki, M ;
Boll, M ;
Fisch, A ;
Bombeli, T ;
Spahn, DR .
BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (05) :569-576
[17]   Reduced quality of clot formation with gelatin-based plasma substitutes [J].
Mardel, SN ;
Saunders, FM ;
Allen, H ;
Menezes, G ;
Edwards, CM ;
Ollerenshaw, L ;
Baddeley, D ;
Kennedy, A ;
Ibbotson, RM .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (02) :204-207
[18]  
Martini W. Z., 2005, AM J PHYSIOL-ENDOC M, V289, P930
[19]  
Menache D, 1981, Ann N Y Acad Sci, V370, P747, DOI 10.1111/j.1749-6632.1981.tb29782.x
[20]   COAGULATION CHANGES DURING PACKED RED-CELL REPLACEMENT OF MAJOR BLOOD-LOSS [J].
MURRAY, DJ ;
OLSON, J ;
STRAUSS, R ;
TINKER, JH .
ANESTHESIOLOGY, 1988, 69 (06) :839-845