Prospective matched-pair analysis of hydroxyapatite- coated and uncoated femoral stems in total hip arthroplasty - A concise follow-up of a previous report

被引:31
作者
Parvizi, J [1 ]
Sharkey, PF [1 ]
Hozack, WJ [1 ]
Orzoco, F [1 ]
Bissett, GA [1 ]
Rothman, RH [1 ]
机构
[1] Rothman Inst, Dept Orthopaed Surg, Philadelphia, PA 19107 USA
关键词
D O I
10.2106/00004623-200404000-00017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This prospective study was performed to examine the results of total hip arthroplasty with a tapered uncemented femoral component with and without hydroxyapatite coating in a matched-pair group of patients. Since our original publication in 1996, no femoral component was revised in either group. After a mean clinical and radiographic follow-up of 9.8 years, all femoral components were stable, with no evidence of progressive radiolucency or osteolysis. Ten acetabular components were revised because of aseptic loosening and wear. Our study demonstrated no clinical or radiographic advantage, during the first decade after implantation, to the use of hydroxyapatite on this design of femoral component in primary total hip arthroplasty. Level of Evidence: Therapeutic study, Level II-1 (prospective cohort study). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:783 / 786
页数:4
相关论文
共 26 条
[1]
BLOEBAUM RD, 1994, CLIN ORTHOP RELAT R, P19
[2]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[3]
RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP [J].
CALLAGHAN, JJ ;
SALVATI, EA ;
PELLICCI, PM ;
WILSON, PD ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1074-1085
[4]
Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old - A concise follow-up of a previous report [J].
Capello, WN ;
D'Antonio, JA ;
Feinberg, JR ;
Manley, MT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :885-889
[5]
CHARNLEY J, 1979, LOW FRICTION ARTHROP, P66
[6]
A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem [J].
Coathup, MJ ;
Blunn, GW ;
Flynn, N ;
Williams, C ;
Thomas, NP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (01) :118-123
[7]
EARLY CLINICAL-EXPERIENCE WITH HYDROXYAPATITE-COATED FEMORAL IMPLANTS [J].
DANTONIO, JA ;
CAPELLO, WN ;
CROTHERS, OD ;
JAFFE, WL ;
MANLEY, MT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :995-1008
[8]
Door L D, 1991, Semin Arthroplasty, V2, P289
[9]
Engh C A, 1984, Hip, P110
[10]
POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55