Simplified intensity-modulated radiotherapy using pre-defined segments to reduce cardiac complications in left-sided breast cancer

被引:44
作者
Cho, BCJ [1 ]
Schwarz, M [1 ]
Mijnheer, BJ [1 ]
Bartelink, H [1 ]
机构
[1] Antoni Van Leeuwenhoek Hosp, Dept Radiotherapy, Netherlands Canc Inst, NL-1066 CX Amsterdam, Netherlands
关键词
intensity-modulated radiotherapy; breast cancer; simplified intensity-modulated radiotherapy; predefined segments;
D O I
10.1016/j.radonc.2003.11.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Left-sided breast cancer patients pose a difficult clinical challenge when significant heart and contralateral breast irradiation are present, particularly with tangential uniform beams. The aims of the study are: (1) to design and evaluate a simplified intensity-modulated radiotherapy (IMRT) (SI) solution using pre-defined segments, (2) to compare the SI technique with a conformal (CN) and a full fluence IMRT (FI) approach using two sets of beam orientations, clinical (-C) and optimal (-O), and (3) to quantify the benefits of treatment technique and beam orientation. Patients and methods: Nine left-sided breast cancer patients with a maximum heart distance of at least 2.0 cm were planned using three different techniques and two different beam orientations. All three techniques were planned using clinical orientations (i.e. CN-C, FI-C and SI-C). Two techniques were planned using more optimal orientations (i.e. FI-O and SI-O). Dose-volume histograms and radiobiologic modelling are used for plan evaluation. Results: The average mean planning target volume (PTV) doses are 91.6 +/- 4.5, 98.4 +/- 6.3, 102.0 +/- 8.7, 100.0 +/- 5.9 and 103.9 +/- 8.3% for the CN-C. FI-C. SI-C, FI-O and SI-O plans, respectively. The average normal tissue complication probabilities for late excess cardiac mortality are 2.1 +/- 0.6 +/- 0.2 +/- 0.1, 0.2 +/- 0.1, 0.1 +/- 0.0 and 0.1 +/- 0.0%, respectively. For a given beam orientation, FI plans are the best and CN plans are the worst. The dose distributions for the SI-C and FI-C plans are almost identical with significant heart sparing but at a cost of some target underdosage. The dose distributions are better conformed around the PTV with more optimal beam orientations, resulting in better sparing of adjacent organs at risk. FI-C plans are inferior to SI-O plans. Conclusions: For clinical uniform two-beam orientations, significant heart sparing is possible with the addition of intensity modulation but at the expense of worsening target coverage. Simplified IMRT can, for all intents, be substituted for full IMRT with clinical beam orientations. Applying more optimal non-Uniform beam orientations improves PTV coverage while maintaining significant heart sparing but increases the PTV dose heterogeneity. (C) 2003 Elsevier lreland Ltd. All rights reserved.
引用
收藏
页码:231 / 241
页数:11
相关论文
共 39 条
[21]  
*INT COMM RAD UN M, 1994, 50 ICRU
[22]   Dose response and latency for radiation-induced fibrosis, edema, and neuropathy in breast cancer patients [J].
Johansson, S ;
Svensson, H ;
Denekamp, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (05) :1207-1219
[23]   Intensity modulation to improve dose uniformity with tangential breast radiotherapy: Initial clinical experience [J].
Kestin, LL ;
Sharpe, MB ;
Frazier, RC ;
Vicini, FA ;
Yan, D ;
Matter, RC ;
Martinez, AA ;
Martinez, AA ;
Wong, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05) :1559-1568
[24]   Radiation pneumonitis as a function of mean lung dose: An analysis of pooled data of 540 patients [J].
Kwa, SLS ;
Lebesque, JV ;
Theuws, JCM ;
Marks, LB ;
Munley, MT ;
Bentel, G ;
Oetzel, D ;
Spahn, U ;
Ten Haken, RK ;
Drzymala, RE ;
Purdy, JA ;
Lichter, AS ;
Martel, MK ;
TEN Haken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (01) :1-9
[25]   Cardiac avoidance in breast radiotherapy: a comparison of simple shielding techniques with intensity-modulated radiotherapy [J].
Landau, D ;
Adams, EJ ;
Webb, S ;
Ross, G .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (03) :247-255
[26]   IS THERE A ROLE FOR POSTOPERATIVE ADJUVANT RADIATION IN BREAST-CANCER - BEAUTIFUL HYPOTHESIS VERSUS UGLY FACTS - 1987 FLETCHER,GILBERT,H. LECTURE [J].
LEVITT, SH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (04) :787-796
[27]   Intensity modulation for breast treatment using static multi-leaf collimators [J].
Lo, YC ;
Yasuda, G ;
Fitzgerald, TJ ;
Urie, MM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (01) :187-194
[28]   A CONVOLUTION METHOD OF CALCULATING DOSE FOR 15-MV X-RAYS [J].
MACKIE, TR ;
SCRIMGER, JW ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1985, 12 (02) :188-196
[29]   Cardiac and pulmonary doses and complication probabilities in standard and conformal tangential irradiation in conservative management of breast cancer [J].
Muren, LP ;
Maurstad, G ;
Hafslund, R ;
Anker, G ;
Dahl, O .
RADIOTHERAPY AND ONCOLOGY, 2002, 62 (02) :173-183
[30]   Postoperative radiotherapy in high-risk premenopausal women with breast cancer who receive adjuvant chemotherapy [J].
Overgaard, M ;
Hansen, PS ;
Overgaard, J ;
Rose, C ;
Andersson, M ;
Bach, F ;
Kjaer, M ;
Gadeberg, CC ;
Mouridsen, HT ;
Jensen, MB ;
Zedeler, K .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 337 (14) :949-955